cs.AINov 25, 2026

Can Its Own Misses Teach an MLLM to Find Small Brain Metastases?

Authors: Yixuan Duan, Kexin Geng, Hanwen Xu, Wei Qiu

Organizations: Rice University · University of Pennsylvania

Abstract

Multimodal large language models (MLLMs) are becoming general readers of medical images, yet they remain weak at locating small abnormalities. Brain metastases expose this gap: at 384 px a 0.1 mL lesion covers less than a quarter of one visual token, and at one false positive per scan frontier MLLMs find fewer than 30% of lesions of 0.1-1 mL. Fine-tuning on one dataset helps but transfers poorly, and improving it further is slow trial and error steered by a single score. We introduce LANTERN (Lesion-finding AgeNt Through Error-driven Recursive learNing), a framework in which an MLLM improves recursively from its own misses. LANTERN recasts model development as an error-driven loop: a failure census attributes every missed lesion to one of four causes, an LLM mentor revises one of four levels (evidence acquisition, visual representation, learning policy, decision aggregation) per round, and a rule frozen before the first round decides what is kept, without test data and with every tool call audited. Over 15 unattended rounds, LANTERN raises a fine-tuned 4B MLLM from finding 75% to 94% of lesions at one false positive per scan on BraTS-MET, and 91% of those of 0.1-1 mL, compared with at most 51% and 29% for five frontier MLLMs read under the starting protocol; the gains hold on an external cohort (89%) and on unseen meningiomas (77%). These results show that an MLLM's own misses, attributed to their causes, can drive its reliable recursive self-improvement.

Figures & tables

Explore similar work

Mar 25, 2026

NeuroVLM-Bench: Evaluation of Vision-Enabled Large Language Models for Clinical Reasoning in Neurological Disorders

Recent advances in multimodal large language models enable new possibilities for image-based decision support. However, their reliability and operational trade-offs in neuroimaging remain insufficiently understood. We present a comprehensive benchmarking study of vision-enabled large language models for 2D neuroimaging using curated MRI and CT datasets covering multiple sclerosis, stroke, brain tumors, other abnormalities, and normal controls. Models are required to generate multiple outputs simultaneously, including diagnosis, diagnosis subtype, imaging modality, specialized sequence, and anatomical plane. Performance is evaluated across four directions: discriminative classification with abstention, calibration, structured-output validity, and computational efficiency. A multi-phase framework ensures fair comparison while controlling for selection bias. Across twenty frontier multimodal models, the results show that technical imaging attributes such as modality and plane are nearly solved, whereas diagnostic reasoning, especially subtype prediction, remains challenging. Tumor classification emerges as the most reliable task, stroke is moderately solvable, while multiple sclerosis and rare abnormalities remain difficult. Few-shot prompting improves performance for several models but increases token usage, latency, and cost. Gemini-2.5-Pro and GPT-5-Chat achieve the strongest overall diagnostic performance, while Gemini-2.5-Flash offers the best efficiency-performance trade-off. Among open-weight architectures, MedGemma-1.5-4B demonstrates the most promising results, as under few-shot prompting, it approaches the zero-shot performance of several proprietary models, while maintaining perfect structured output. These findings provide practical insights into performance, reliability, and efficiency trade-offs, supporting standardized evaluation of multimodal LLMs in neuroimaging.
Apr 15, 2026

MedRCube: A Multidimensional Framework for Fine-Grained and In-Depth Evaluation of MLLMs in Medical Imaging

The potential of Multimodal Large Language Models (MLLMs) in domain of medical imaging raise the demands of systematic and rigorous evaluation frameworks that are aligned with the real-world medical imaging practice. Existing practices that report single or coarse-grained metrics are lack the granularity required for specialized clinical support and fail to assess the reliability of reasoning mechanisms. To address this, we propose a paradigm shift toward multidimensional, fine-grained and in-depth evaluation. Based on a two-stage systematic construction pipeline designed for this paradigm, we instantiate it with MedRCube. We benchmark 33 MLLMs, Lingshu-32B achieve top-tier performance. Crucially, MedRCube exposes a series of pronounced insights inaccessible under prior evaluation settings. Furthermore, we introduce a credibility evaluation subset to quantify reasoning credibility, uncover a highly significant positive association between shortcut behavior and diagnostic task performance, raising concerns for clinically trustworthy deployment. The resources of this work can be found at https://github.com/F1mc/MedRCube.
Jun 5, 2026

Automatic Extraction of Structured Information from Brain MRI Reports Using an Open-Weight Large Language Model

Objectives: Automatic data extraction from free-text radiology reports enables large-scale research, but few studies assessed the performance of large language models (LLMs) on Dutch neuroradiology reports. Methods: We analyzed 947 brain MRI reports from a tertiary memory clinic (2016-2021), authored by consultant neuroradiologists. Trained medical students annotated thirty variables; 100 reports were double-annotated to assess inter-rater reliability. We evaluated the performance of the open-weight LLM LLaMA 3.1 using different languages (Dutch vs. English translation) and few-shot prompting with different example selection strategies. Performance was evaluated using balanced accuracy for categorical variables, accuracy and mean absolute error for counts, and text similarity for free-text. Metrics were computed across 10 random splits of the 947 reports. Results: LLaMA 3.1 demonstrated high zero-shot performance for visual rating scores (mean [95%-CI]): Medial Temporal Atrophy: 90% [77-100%] on the left and 96% [94-99%] on the right, Global Cortical Atrophy: 87% [83-91%], and Fazekas: 94% [93-96%]. Microbleed mentions were detected with 93% accuracy [92-95%] and infarct mentions with 82% [80-84%]. Text similarity for lesion location reached 0.95 [0.95-0.96]. Performance was lower for numerical variables: 80% [78-82%] for the number of microbleeds and 66% [63-68%] for infarcts. English translation yielded comparable results. Few-shot prompting improved performance for numerical variables, achieving 92% [90-93%] for microbleeds and 81% [77-85%] for infarcts using structural similarity-based selection. Conclusion: LLaMA 3.1 shows strong potential for extracting data from Dutch neuroradiology reports. Few-shot prompting enhances performance for numerical variables, whereas challenges remain for location-specific variables.