TAT-Det: A Dataset for Testicular Appendage Torsion Detection and Segmentation in Ultrasound Images
Organizations: Department of Ultrasound, Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children and Adolescents’ Health and Diseases, Hangzhou, Zhejiang, China · College of Control Science and Engineering, Zhejiang University, Hangzhou, Zhejiang, China · Data Science Institute, Vanderbilt University, Nashville, Tennessee, USA · Innovation Center for Electronic Design Automation Technology, Hangzhou Dianzi University, Hangzhou, Zhejiang, China
Abstract
Background: Testicular appendage torsion (TAT) is the leading cause of acute scrotal pain in prepubertal children. Yet, its diagnosis remains challenging due to nonspecific clinical manifestations and the absence of standardized datasets for pediatric acute scrotal emergencies. Results: We present TAT-Det, an expert-annotated ultrasound dataset specifically designed for TAT. TAT-Det comprises 2,600 ultrasound images from 1,203 patients collected at the Children's Hospital, Zhejiang University School of Medicine. Each TAT-positive image is accompanied by lesion-level bounding boxes for detection and pixel-level segmentation masks for fine-grained delineation. Annotations were produced through a multi-stage workflow involving independent annotation by board-certified pediatric sonographers, consensus review, and refinement. Baseline benchmarks for object detection and semantic segmentation using representative deep learning models are further provided, with YOLO11m achieving the best detection performance and RWKV-UNet the best segmentation performance. Conclusions: TAT-Det addresses the lack of publicly available resources for pediatric emergency ultrasound and establishes a foundation for developing and evaluating artificial intelligence methods for automated TAT analysis.
Figures & tables
| Dataset | Organ / Anatomy | Images | Annotation Type | Task Type |
| BUSI [ 1 ] | Breast lesion | 780 | Pixel-level masks; lesion category labels | Segmentation; classification |
| BUS-BRA [ 8 ] | Breast lesion | 1,875 | Pixel-level masks; BI-RADS labels | Segmentation; BI-RADS grading |
| UDIAT [ 41 ] | Breast lesion | 163 | Pixel-level masks; lesion labels | Segmentation; classification |
| DDTI [ 32 ] | Thyroid nodule | 637 | Nodule contours | Segmentation |
| TN3K [ 9 ] | Thyroid nodule | 3,493 | Pixel-level masks | Segmentation |
| EchoNet-Dynamic [ 31 ] | Heart (echocardiography) | 10,030 videos | Ventricle tracings; ejection-fraction values | Video segmentation; cardiac function regression |
| Min | Max | Mean | SD | Median | IQR | Q1 | Q3 |
| 0.2 | 17.2 | 9.3 | 2.7 | 9.8 | 3.3 | 7.9 | 11.2 |
| Manufacturer | Model | Patients |
| GE Healthcare | GE LOGIQ E20 | 518 |
| GE Healthcare | GE LOGIQ E9 | 325 |
| Philips | Philips | 232 |
| Mindray | Resona R9T | 69 |
| Mindray | Resona A20T | 17 |
| Mindray | Resona 7S | 1 |
| Metric (%) | N | Mean | Median | Std | IoU 50%, n (%) |
| BBox IoU | 1,725 | 80.3 | 84.1 | 15.0 | 69 (4.0) |
| Mask IoU | 1,725 | 83.8 | 93.8 | 23.9 | 160 (9.3) |
| Subset | Patients | Pos. | Neg. | Total Img. |
| train/ | 941 | 1,326 | 695 | 2,021 |
| val/ | 131 | 197 | 92 | 289 |
| test/ | 131 | 202 | 88 | 290 |
| Total | 1,203 | 1,725 | 875 | 2,600 |
| Model | [email protected] (%) | [email protected]:0.95 (%) |
| YOLOv5n [ 17 ] | 88.36 | 52.42 |
| YOLOv5s [ 17 ] | 87.41 | 50.53 |
| YOLOv5m [ 17 ] | 88.52 | 51.10 |
| YOLOv5l [ 17 ] | 85.11 | 49.25 |
| YOLOv5x [ 17 ] | 84.10 | 48.67 |
| YOLOv8n [ 14 ] | 88.53 | 52.18 |
| Model | Dice | IoU | HD95 |
| UNet [ 33 ] | 76.83 | 70.45 | 11.06 |
| Att-UNet [ 30 ] | 77.41 | 70.89 | 11.42 |
| UNet++ [ 42 ] | 76.54 | 69.84 | 12.60 |
| TransUNet [ 4 ] | 81.42 | 74.65 | 8.01 |
| Swin-Unet [ 3 ] | 77.16 | 69.50 | 9.06 |
| LV-UNet [ 12 ] | 77.40 | 69.13 | 9.96 |
Medical Image Benchmarks
Medical image benchmarks compare AI methods on curated clinical images, tasks, and evaluation protocols to measure accuracy, robustness, and clinical usefulness.
See all 390 papers