World-space human mesh recovery can lose spatial consistency even when camera-space body estimates are accurate. A single sequence-wide scale resolves global scale ambiguity but cannot correct local scale distortion along a reconstructed camera path. We present ScaleCurve, a framework that estimates time-varying metric corrections from human-ground geometry. We construct scale observations by comparing predicted foot geometry with locally fitted ground planes. Joint temporal optimization downweights inconsistent observations and couples neighboring scale estimates, allowing calibration to adapt along the camera path without freely following measurement noise. We scale camera translation increments and integrate them into a calibrated trajectory. With this camera fixed, we refine the lifted body motion using 2D image evidence and pretrained 3D dynamics, while restricting global trajectory rescaling. ScaleCurve achieves state-of-the-art performance on most evaluated metrics on both EMDB-2 and SLOPER4D. Consistent gains across three HMR backbones demonstrate its compatibility with diverse body estimates without retraining. Code will be made publicly available.
Figures & tables
Figure 1: Scale drift in world-space HMR. Monocular world-space HMR inherits camera scale ambiguity. A single sequence-wide scale can correct the overall scale but leave local distortions that accumulate into human trajectory drift. ScaleCurve instead estimates a time-varying scale correction to reduce this error.
Figure 2: Oracle scale comparison on EMDB-2 and SLOPER4D examples. Constant-scale and temporal-scale oracles are fitted using GT camera trajectories and used to lift identical camera-space body estimates on EMDB-2 (left) and SLOPER4D (right). Temporal correction reduces camera error and improves agreement with GT human trajectories in both examples, with a larger benefit in the SLOPER4D example exhibiting pronounced scale variation. See the supplementary material for oracle construction details and additional oracle results.
Figure 3: Overview of ScaleCurve. SLAM provides camera poses and scene geometry, while HMR provides camera-coordinate body estimates. (A) Temporal Scale Calibration forms metric scale observations from human-ground geometry at available keyframes and estimates a time-varying correction through robust temporal optimization. The estimated scales calibrate camera translation increments, which are integrated into a metric camera trajectory to lift the body into world coordinates. (B) Camera-Consistent Motion Refinement then improves the lifted motion using 2D image evidence and pretrained 3D dynamics while keeping the calibrated camera fixed.
Method
Venue
W-MPJPE
WA-MPJPE
RTE
MPJVE
MPJAE
Jitter
FS
TRAM [ 39 ]
ECCV 2024
222.4
76.4
1.4
0.4 ∗
8.6 ∗
29.5 ∗
11.6 ∗
GVHMR [ 28 ]
SIGGRAPH Asia 2024
276.5
111.0
2.0
0.4 ∗
6.7 ∗
16.7
3.5
PromptHMR-Vid [ 38 ]
CVPR 2025
216.5
71.0
1.3
–
–
16.3
3.5
HAC [ 41 ]
ICCV 2025
197.2
71.0
1.2
0.4 ∗
8.6 ∗
29.5 ∗
11.3 ∗
GENMO [ 17 ]
ICCV 2025
202.1
74.3
1.2
–
–
17.8
8.8
JOSH 3 † [ 22 ]
ICLR 2026
174.7
68.9
1.3
–
–
9.1
12.1
Table 1: Comparison on EMDB-2. Baseline results are quoted from the original papers, except for values marked ∗ , which we compute using official model releases to supplement unreported metrics. † denotes additional joint scene reconstruction with human-scene contact constraints. Bold and underline denote the best and second-best reported values.
Method
Venue
W-MPJPE
WA-MPJPE
RTE
MPJVE
MPJAE
Jitter
FS
TRAM ∗ [ 39 ]
ECCV 2024
999.4
174.9
5.3
1.4
32.3
101.2
62.4
GVHMR ∗ [ 28 ]
SIGGRAPH Asia 2024
959.1
153.7
5.2
1.1
26.2
83.2
46.0
HAC ∗ [ 41 ]
ICCV 2025
1056.4
237.7
4.0
1.3
32.1
100.7
58.3
JOSH 3 † [ 22 ]
ICLR 2026
438.3
120.0
1.7
–
–
7.1
28.2
HumanBA [ 42 ]
CVPR 2026
674.5
122.7
–
–
–
–
–
HTD-Refine ∗ [ 40 ]
CVPR 2026
950.9
142.3
5.3
0.7
10.1
18.2
26.7
Table 2: Comparison on SLOPER4D. Baselines marked ∗ are evaluated by us using official model releases under our protocol; the remaining baseline results are quoted from the original papers. † denotes additional joint scene reconstruction with human-scene contact constraints. Bold and underline denote the best and second-best reported values.
Variant
ATE
W-MPJPE
RTE
Robust Temporal Scale Optimization
Temporal → Constant scale
7.52
708.12
2.93
Optimization → Gaussian smoothing
5.86
503.77
1.87
Student- t→ Gaussian likelihood
5.47
481.39
1.73
w/o random-walk prior
5.30
522.37
1.89
Human-Ground Scale Observations
Table 3: Ablation of Temporal Scale Calibration on SLOPER4D. Arrows denote replacing the left-hand component with the right-hand alternative, while “w/o” denotes removal. The same human motion refinement is applied to all variants.
Variant
W-MPJPE
MPJVE
MPJAE
Camera only
473.76
0.95
26.01
w/o 2D image alignment
465.22
0.44
7.10
w/o 3D dynamics matching
455.04
0.48
7.41
w/o motion regularization
494.97
0.68
14.90
Full refinement
446.83
0.43
7.12
Table 4: Ablation of Camera-Consistent Motion Refinement on SLOPER4D. “Camera only” excludes human motion refinement, while “w/o” denotes component removal. All variants share the same calibrated camera and initialization.
Backbone
W-MPJPE
RTE
MPJVE
MPJAE
TRAM [ 39 ]
999.45
5.26
1.35
32.29
+ ScaleCurve
489.00
1.50
0.48
7.53
Human3R [ 3 ]
1345.14
5.58
1.73
39.14
+ ScaleCurve
870.27
1.86
0.69
8.77
GVHMR [ 28 ]
959.08
5.22
1.09
26.18
+ ScaleCurve
446.83
1.47
0.43
7.12
Table 5: Body-backbone compatibility on SLOPER4D. Each body backbone uses the same initial TRAM camera trajectory.
Figure 4: Qualitative comparison of human motion. Reconstructed human meshes from HAC [ 41 ] , HTD-Refine [ 40 ] , and ScaleCurve are overlaid with GT (gray) in world coordinates on EMDB-2 (left) and SLOPER4D (right). Time progresses downward.
Figure 5: Qualitative comparison of scale and trajectories. Estimated scales (left) and world-space human trajectories (right) from HAC [ 41 ] and ScaleCurve on EMDB-2 (top) and SLOPER4D (bottom). Gray dashed curves indicate the GT-assisted scale oracle and GT trajectories, respectively.
Appendix figures & tables17 assets
Supplementary material from the paper’s appendix.
Appendix
Calibrated observation parameters
Observation configuration
Bias offset κ
Noise scale σ
Degrees of freedom ν
SLOPER4D configuration
−0.005409
0.049418
1.318450
EMDB-2 configuration
−0.033496
0.050579
1.070191
Fixed camera-stage settings
Setting
Value
Frame rate; temporal interval Δ
30 fps; 1 s
Appendix
Table 6: Calibration parameters and fixed settings. The observation parameters are estimated on BEDLAM2.0 training data and held fixed during inference; no additional network is trained. Other settings are shared across EMDB-2 and SLOPER4D unless noted. Image residual scales are specified at 1280×960 resolution.
Oracle
ATE (m)
W-MPJPE (mm)
EMDB-2 (25 sequences)
Constant-scale oracle
0.33
177.19
Temporal-scale oracle
0.24
168.71
SLOPER4D (6 sequences)
Constant-scale oracle
7.18
745.09
Temporal-scale oracle
1.89
360.32
Appendix
Table 7: Oracle scale comparison across both benchmarks. Camera ATE and W-MPJPE are sequence averages over all 25 EMDB-2 and six SLOPER4D sequences. Both oracles lift identical bodies on the same diagnostic support.
EMDB-2
SLOPER4D
Variant
TSC
CMR
W-MPJPE
RTE
MPJVE
MPJAE
W-MPJPE
RTE
MPJVE
MPJAE
GVHMR + TRAM camera
×
×
202.16
1.32
0.34
6.43
959.08
5.22
1.09
26.18
Calibration only
✓
×
163.00
0.99
0.34
6.43
473.76
1.49
0.95
26.01
Refinement only
×
✓
196.54
1.32
0.32
5.45
933.86
5.21
0.62
7.20
Full ScaleCurve
✓
✓
154.35
0.99
0.31
5.45
446.83
1.47
0.43
7.12
Appendix
Table 8: Complementarity of the two stages. TSC: Temporal Scale Calibration; CMR: Camera-Consistent Motion Refinement. Crosses disable the corresponding stage; the first row lifts GVHMR with the TRAM camera. All variants share the same initial body and camera estimates. Both datasets use the main evaluation protocols.
Variant
ATE
W-MPJPE
RTE
Robust Temporal Scale Optimization
Temporal → Constant scale
0.70
168.97
1.13
Optimization → Gaussian smoothing
4.45
319.38
7.71
Student- t→ Gaussian likelihood
0.80
173.96
1.36
w/o random-walk prior
6.35
379.54
11.04
Human-Ground Scale Observations
Appendix
Table 9: Temporal Scale Calibration ablation on EMDB-2. All variants include the same human motion refinement and use the main evaluation protocol. Arrows indicate replacement; w/o denotes removal.
Figure 6: Sensitivity of temporal scale calibration. Variable interval Δ and random-walk variance rate q are varied independently, with all other settings fixed. Camera ATE is normalized by the default within each dataset. The q axis scales the default 1.6×10−4 ; bold ticks mark the main-paper settings.
Figure 7: Scale observations, robust weights, and convergence. Left: log-scale observations and the optimized correction on SLOPER4D Running (top), with Student- t weights normalized by their zero-residual value (bottom). The dashed curve is the GT-assisted temporal oracle. Right: the optimization objective over IRLS iterations; iteration zero is the equal-weight initialization.
Rescaling rule
EMDB-2 ATE
SLOPER4D ATE
Translation increments
0.583
4.358
Absolute positions
0.819
38.814
Appendix
Table 10: Comparison of scale application rules. Camera ATE (m), averaged across sequences, for scaling translation increments versus absolute camera positions. Both use identical estimated scales and camera rotations.
Figure 8: Robustness to contaminated scale observations. Camera ATE under identical added outliers, with all other calibration settings fixed. Error bars show standard deviation across three seeds after averaging sequences. Zero contamination uses the original observations.
EMDB-2
SLOPER4D
Variant
W-MPJPE
MPJVE
MPJAE
W-MPJPE
MPJVE
MPJAE
w/o image-conditioned priors ( Rimg )
165.91
0.317
5.58
483.41
0.422
6.96
w/o velocity anchoring ( Ranchor )
155.76
0.314
5.46
450.53
0.432
7.11
w/o motion smoothness ( Rsmooth )
152.44
0.316
5.81
452.57
0.727
18.47
Full regularization
154.35
0.311
5.45
446.83
0.430
7.12
Appendix
Table 11: Ablation of motion regularization. Each removal is relative to full refinement. The calibrated camera, initialization, motion evidence, optimization budget, and root-scale constraint are shared.
Variant
W-MPJPE
MPJVE
MPJAE
Camera only
163.00
0.34
6.43
w/o 2D image alignment
178.18
0.33
5.56
w/o 3D dynamics matching
156.22
0.31
5.49
w/o motion regularization
161.39
0.33
6.25
Full refinement
154.35
0.31
5.45
Appendix
Table 12: Camera-Consistent Motion Refinement ablation on EMDB-2. All 25 EMDB-2 sequences use the main comparison preprocessing. Camera only excludes refinement; each removal is relative to the full stage.
EMDB-2
SLOPER4D
Methods
W-MPJPE
RTE
MPJVE
MPJAE
W-MPJPE
RTE
MPJVE
MPJAE
ViPE [ 11 ]
239.12
2.41
0.36
6.44
534.39
2.64
1.07
27.50
+ ScaleCurve
152.44
1.13
0.31
5.44
448.77
1.18
0.46
7.28
MegaSaM [ 20 ]
281.41
2.95
0.41
6.61
804.32
5.13
1.30
29.03
+ ScaleCurve
169.86
1.51
0.35
5.69
488.09
2.48
0.65
7.40
DROID-SLAM [ 35 ]
202.16
1.32
0.34
6.43
959.08
5.22
1.09
26.18
Appendix
Table 13: Compatibility with different camera reconstruction methods. Each base combines the named camera reconstruction method and its reconstructed geometry with GVHMR; + ScaleCurve applies both calibration and human refinement. Each pair uses identical sequence and frame support. W-MPJPE: mm; RTE: %; MPJVE/MPJAE: m/s and m/s 2 .
Backbone
W-MPJPE
RTE
MPJVE
MPJAE
TRAM [ 39 ]
257.16
1.32
0.40
8.62
+ ScaleCurve
197.29
1.13
0.34
6.70
Human3R [ 3 ]
293.27
1.45
0.60
17.25
+ ScaleCurve
250.06
1.09
0.38
8.07
GVHMR [ 28 ]
202.16
1.32
0.34
6.43
+ ScaleCurve
154.35
0.99
0.31
5.45
Appendix
Table 14: Body-backbone compatibility on EMDB-2. Each backbone uses the same initial TRAM camera. The second row applies the complete ScaleCurve pipeline. Both rows share inputs and benchmark support.
Stage
FPS
Runtime (%)
Preprocessing
1.26
98.84
TSC
1018.47
0.12
CMR
119.91
1.04
Full ScaleCurve
1.25
100.00
Appendix
Table 15: Computational cost of ScaleCurve. TSC and CMR denote Temporal Scale Calibration and Camera-Consistent Motion Refinement, respectively. FPS denotes stage-specific throughput, while the final row reports full-pipeline throughput. Runtime (%) indicates each stage’s fraction of the total runtime.
Figure 9: Qualitative human motion comparisons on EMDB-2. Three timestamps from each of two supplementary clips, with time progressing downward within each example. GVHMR (yellow), HAC and HTD-Refine (orange), and ScaleCurve (blue) are overlaid with GT (gray) in world coordinates. All methods share a fixed view and display scale within each clip.
Figure 10: Qualitative human motion comparisons on SLOPER4D. Three timestamps from SLOPER4D examples, with time progressing downward within each example. GVHMR (yellow), HAC and HTD-Refine (orange), and ScaleCurve (blue) are overlaid with GT (gray) in world coordinates. All methods share a fixed view and display scale within each clip.
Figure 11: Qualitative scale and trajectory comparisons. Estimated scales (left) and world-space human root trajectories (right) for example sequences from EMDB-2 (top) and SLOPER4D (bottom). Gray dashed curves denote the GT-assisted temporal oracle in the scale plots and GT in the trajectory plots.
Figure 12: Failure case: persistent body-orientation errors. Predictions at three timestamps are overlaid with GT (gray), with time progressing downward. Method colors and the display protocol follow Fig. 9 .