BOT-Scale: A Traceable Evaluation Methodology for Robotic Manipulation
Abstract
A successful manipulation rollout can still involve a mid-task object drop or a placement deviation. Existing evaluators reduce such deviations to a single score or attach explanations computed separately; the score itself explains neither its basis nor what to fix. We show that a manipulation score becomes traceable when defined as the sum of outcome-conditioned penalties over retained behavioral-factor records. Explanation and score share the same computation, so each factor-level deduction names an inspectable deviation. BOT-Scale applies this principle by adapting behavioral assessment scales from medicine. It organizes twelve candidate factors into four assessment layers; each factor is tied to observable evidence and an explicit decision criterion. Reference calibration fixes a penalty per factor, and a closed-form rule aggregates the factor records into a score with per-factor contributions. We developed BOTScorer, an automatic scoring system based on the seven factors retained by data-driven screening, to validate this methodology. We provide BOT-Events, a dataset with eight-rater quality scores and factor-event annotations, alongside the traceable, interpretable score. The code will be released publicly.
Figures & tables
| ID | Factor | Referenced assessment item | Borrowed template element |
| Perception and understanding | |||
| f1 | Progress-tracking failure | economy-of-motion items in technical-skill rating [ 19 , 20 ] | progress features: mid-task stalls, retries |
| f2 | Temporal-order confusion | task-step sequencing in ADL-based assessment [ 10 ] | order judged against required subtask states |
| f3 | Physical-state misjudgment | compositional action–state rules in action quality assessment [ 22 ] | action contradicting the physical relation |
| Planning and logic | |||
| f4 | Primitive-sequence error | flow-of-operation and forward-planning items [ 19 ] | prerequisite graph as the decision rule |
| Reference | Assessment basis and use |
|---|---|
| Katz ADL [ 10 ] | Six daily activities (e.g., bathing, dressing), judged by unassisted performance; standard geriatric functional-independence summary. |
| GCS [ 26 ] | Eye/verbal/motor channels with distinct ordered levels; impaired consciousness across raters and settings. |
| OSATS [ 19 ] | Operative execution: respect for tissue, time/motion, instrument handling, procedure knowledge; OSATS and derivatives used in surgical training/assessment. |
| Automated variants | Observed video actions ground grades [ 20 ] ; explicit motion rules assess compositional action quality [ 22 ] . |
| Task | RoboMeter | PRM-SQS | RoboJev | BOTScorer | |
|---|---|---|---|---|---|
| T1 | 68 (51/17) | 0.65 | 0.74 | 0.67 | 0.87 |
| T2 | 78 (47/31) | 0.41 | 0.81 | 0.66 | 0.88 |
| T3 | 86 (56/30) | 0.57 | 0.73 | 0.51 | 0.79 |
| T4 | 66 (66/0) | 0.06 | 0.30 | 0.24 | 0.33 |
| T5 | 56 (49/7) | 0.25 | 0.40 | 0.45 | 0.79 |
| T6 | 138 (57/81) | 0.33 | 0.79 | 0.63 | 0.74 |
| Model | Acc. (%) | mF1 | s/rollout |
|---|---|---|---|
| Qwen3-VL-2B (Zero-shot) | 7.11 | 0.031 | 6.2 |
| InternVL3.5-1B (Zero-shot) | 0.84 | 0.036 | 7.6 |
| Qwen3-VL-2B (SFT) | 92.47 | 0.888 | 6.2 |
| Qwen3.5-2B (SFT) | 86.61 | 0.814 | 13.6 |
| Qwen3.5-0.8B (SFT) | 89.54 | 0.876 | 12.7 |
| InternVL3-2B (SFT) | 89.54 | 0.870 | 6.7 |
| Set | M10 | Set | M10 | ||
|---|---|---|---|---|---|
| full-7 | 0.79 | — | f7 | 0.85 | |
| f1 | 0.79 | f8 | 0.78 | ||
| f4 | 0.78 | f9 | 0.78 | ||
| f6 | 0.80 | f12 | 0.78 |
Robot Manipulation Benchmarks
Robot manipulation benchmarks measure how reliably robots perceive, plan, and execute physical tasks across objects, settings, and embodiments.
See all 399 papers