Path-traced rendering shows CT and MR volumes with realistic lighting, but it restarts after every change of view, clipping plane or transfer function (TF), the map from voxel intensity to colour and opacity, which limits the frame rate. Feed-forward Gaussian splatting models such as RenderFM predict the Gaussians directly from the volume instead of fitting them to each scan, and are fast. RenderFM, however, handles only CT, runs its network again after every TF edit, has no clipping operator, and places its Gaussians on a uniform 3-mm grid that blurs organ boundaries and cut faces. We present RenderFM-Next, a feed-forward model that addresses these limits. One network handles both CT and MR. Its Gaussians are predicted once per volume: a new TF needs no pass of this network, and a clipping plane cuts them exactly, using operators from prior work. The model predicts coarse 3-mm Gaussians for the whole volume and refines them to 1.5 mm only where refinement improves the image. A small score head ranks the coarse Gaussians by how much refining them would reduce the rendering error; at render time the user chooses how many are refined, and those next to a clipping plane are always refined, which sharpens cut faces. We build a benchmark of about 2,000 CT and MR scans with path-traced references under clinical presets, TF edits and clipping. Our RenderFM-Next improves over RenderFM retrained on this benchmark by 2.8 dB on CT and 2.4 dB on MR and renders a 1600x1600 view in 4-6 ms. Refinement adds 0.30 / 0.69 dB over the same model trained without it (0.51 / 1.17 dB on cut faces), and refining a learned 10% of the coarse Gaussians matches a random 50% with 2.4x fewer Gaussians. Project page: https://gaozhongpai.github.io/renderfmnext/
Figures & tables
RenderFM-Next (Ours)
RenderFM [ 17 ]
Parents only
Children ( ρ=20% )
CT and MR in one network
–
✓
✓
New TF, no U-Net pass
–
✓
✓
Exact clipping-plane cut
–
✓
✓
Adjustable refinement
–
–
✓
Refined cut faces
–
–
✓
Table 1: RenderFM and RenderFM-Next side by side. Top: capabilities. Bottom: quality ( Tab. 2 ) and cost ( Sec. 5.4 ) on CT / MR. ρ : fraction of parents refined.
Figure 2: Overview of RenderFM-Next. Once per volume, one U-Net for CT and MR predicts 3-mm parent Gaussians (green), up to eight 1.5-mm children per parent (orange) and a score that ranks the parents (blue). At render time, the top- K parents under the budget ρ and those next to the clipping plane H are replaced by their children. Bottom: training stages.
All reported families
PSNR by family
Mod.
Method
PSNR ↑
SSIM ↑
LPIPS ↓
Base uncut
Base clipped
Clinical presets
Preset + edit
Fam.- bal.
#G
FPS
CT
RenderFM [ 17 ] (retrained)
26.87
0.936
0.085
26.91
27.25
25.72
26.32
26.55
0.35
99
RenderFM-Next (parents only)
29.39
0.948
0.068
29.96
29.69
27.32
28.98
28.99
0.35
225
RenderFM-Next (joint)
29.69
0.951
0.057
30.31
30.05
27.42
28.95
29.18
0.89
162
RenderFM-Next (specialist)
29.80
0.952
0.056
30.41
30.20
27.53
28.85
29.25
0.90
163
MR
RenderFM [ 17 ] (retrained)
26.25
0.921
0.148
26.74
25.56
28.40
26.78
26.87
0.17
159
Table 2: CT and MR results by family (test: 67 CT, 115 MR patients; PSNR in dB, per-patient mean). All: all frames; Fam.-bal.: mean of the four family means; #G: Gaussians per view (millions); FPS: at 16002 ( Tab. 1 ). RenderFM: retrained, one model per modality. Parents only: RenderFM-Next without children (same #G as RenderFM). Bold: best single model. Grey: one model per modality.
CT
MR
#G
Δ PSNR
#G
Δ PSNR
Test, vs. the parents-only model (29.39 / 27.95 dB)
Children switched off
0.35
− 0.19 [ − 0.21, − 0.17]
0.17
− 0.24 [ − 0.26, − 0.22]
RenderFM-Next
0.89
+0.30 [+0.28, +0.32]
0.42
+0.69 [+0.66, +0.71]
Validation, learned 20% minus alternative (#G of the alternative)
Random selection
0.82
+0.18 [+0.16, +0.21]
0.49
+0.18 [+0.16, +0.21]
Table 3: Effect of refinement. PSNR differences (dB, 95% CIs); #G in millions. Top : relative to the parents-only model (test). Bottom : learned selection at 20% minus each alternative (validation).
Figure 3: Quality vs. rendered Gaussians (test). PSNR gain of RenderFM-Next over the parents-only model (95% CIs) with learned and with random selection at ρ∈{10,20,30,50}% .
Figure 4: Qualitative comparison on clipped clinical presets (validation; full-frame PSNR in dB, best in bold). CT rows: abdomen, soft-tissue and bone presets; MR rows: anatomical preset on knee, spine, abdomen and pelvis scans. Children sharpen cut faces and thin structures that the parents-only model and RenderFM (retrained) blur.
Source
Region
n
RenderFM
Parents only
RenderFM-Next
Spec.
TotalSeg. CT
various
67
26.87
29.39
29.69
29.80
TotalSeg. MRI
various
23
25.60
27.18
27.78
28.02
IXI
head
32
26.72
28.60
29.35
29.68
AOMIC
head
19
27.80
29.56
30.39
30.74
SPIDER
spine
5
25.83
27.28
27.92
28.20
SKM-TEA
knee
36
25.49
27.09
27.72
27.97
Table 4: Results per data source (test; PSNR in dB, all reported families; n : patients). Top row: CT; other rows: MR. Grey: one model per modality.
Appendix figures & tables10 assets
Supplementary material from the paper’s appendix.
Appendix
Source
Anatomy / sequence
Train
Val.
Test
CT: TotalSegmentator [ 50 ]
whole body
895
46
67
MR: TotalSegmentator MRI [ 1 ]
body, mixed
187
17
23
MR: IXI [ 21 ]
head, T1/T2
278
25
32
MR: AOMIC [ 41 ]
head, T1
166
15
19
MR: SPIDER [ 46 ]
lumbar spine, T2
32
4
5
MR: SKM-TEA [ 8 ]
knee, qDESS
109
10
36
Appendix
Table 1: Benchmark sources and splits (scans). CT excludes 84 thick-slice scans; MR excludes one degenerate scan.
Source
Scans
In-plane spacing (mm)
Slice spacing (mm)
FOV (mm)
Grid (M voxels)
Labels
Parents (M)
Cand. children (M)
#G, test (M)
CT: TotalSegmentator
1008
1.5 ∗
1.5 ∗
405 [332, 572]
106.2 [53.7, 192.2]
74 [52, 100]
0.43 [0.22, 0.62]
3.17 [1.64, 4.58]
0.92 [0.54, 1.16]
MR: TotalSeg. MRI
227
1.09 [0.73, 1.25]
2.50 [1.50, 3.00]
380 [256, 400]
49.3 [22.4, 66.9] 9
25 [6, 29]
0.39 [0.15, 0.64]
3.08 [1.16, 5.07]
0.95 [0.34, 1.38]
MR: IXI
335
0.94 [0.94, 0.94]
1.20 [1.20, 1.20]
240 [240, 240]
24.5 [24.5, 24.7]
6 [6, 6]
0.15 [0.14, 0.17]
1.21 [1.10, 1.31]
0.39 [0.33, 0.42]
MR: AOMIC
200
1.00 [1.00, 1.00]
1.00 [1.00, 1.00]
256 [256, 256]
24.8 [24.8, 24.8]
6 [5, 6]
0.12 [0.11, 0.13]
0.95 [0.90, 1.04]
0.30 [0.28, 0.33]
MR: SPIDER
41
0.47 [0.47, 0.47]
0.90 [0.90, 0.90]
300 [300, 300]
18.4 [18.4, 18.7]
3 [3, 3]
0.13 [0.12, 0.14]
0.99 [0.91, 1.12]
0.30 [0.29, 0.31]
MR: SKM-TEA
155
0.31 [0.31, 0.31]
0.80 [0.80, 0.80]
160 [160, 160]
7.8 [7.8, 7.8]
9 [8, 9]
0.06 [0.05, 0.06]
0.43 [0.40, 0.48]
0.14 [0.13, 0.15]
Appendix
Table 2: Dataset statistics per source (all splits; median [IQR] over scans). Spacing: smallest / largest native voxel spacing; FOV: longest extent; grid: working grid (superscript: scans at 1.0 instead of 0.75 mm); labels: anatomy labels present; parents: 3-mm grid; #G: rendered per view at ρ=20% (test). ∗ CT release resampled to 1.5 mm.
Mod.
Split
Base uncut
Base clipped
Clinical presets
Preset + edit
All
CT
Val.
46 / 1,472
46 / 1,932
46 / 724
46 / 184
46 / 4,312
Test
67 / 2,144
67 / 2,814
67 / 1,043
67 / 268
67 / 6,269
MR
Val.
71 / 2,272
71 / 2,982
71 / 394
–
71 / 5,648
Test
115 / 3,680
115 / 4,830
115 / 660
115 / 230
115 / 9,400
Appendix
Table 3: Evaluation frames . Top: patients / frames per reported family (validation has no MR preset+edit frames). Bottom: patients eligible for each reported preset (val. / test).
Stage
Steps
LR
Views
GPU-h
CT pretraining
32k
10−4
32
47
Joint CT+MR
12k + 3k
5×10−5
16, 8
17
Children
8.4k
5×10−5
20
21
Appendix
Table 4: Training stages of the final model. The first two rows form step 1 of the main paper (parents) and the last row step 2 (children). Views: rendered views per update.
Base uncut
Base clipped
Clinical presets
Preset + edit
Mod.
Method
SSIM
LPIPS
Edge
SSIM
LPIPS
Edge
SSIM
LPIPS
Edge
SSIM
LPIPS
Edge
Cut
CT
RenderFM
0.933
0.088
17.81
0.939
0.081
17.51
0.933
0.090
15.86
0.935
0.085
16.84
19.36
RenderFM-Next (Ours)
0.951
0.057
20.88
0.955
0.050
20.24
0.943
0.074
17.50
0.951
0.073
18.89
21.46
Specialist (Ours)
0.951
0.056
20.96
0.955
0.049
20.35
0.943
0.074
17.54
0.952
0.072
18.89
21.54
MR
RenderFM
0.929
0.150
17.14
0.911
0.151
17.07
0.947
0.106
17.13
0.931
0.142
17.46
18.64
RenderFM-Next (Ours)
0.943
0.126
19.22
0.933
0.095
19.47
0.955
0.085
17.76
0.944
0.110
19.03
21.24
Appendix
Table 5: Per-family metrics for the models of Tab. 2 of the main paper (test; patient means over the reported families). Edge: PSNR within 4 px of strong reference gradients. Cut: cut-face PSNR over all clipped reported views. Grey: one model per modality.
Figure 1: Representative views , one per reported family (validation; full-frame PSNR in dB, best in bold). Each example is the frame whose PSNR gain over retrained RenderFM is the median of its family.
Mod.
Preset
n
RenderFM
RenderFM-Next (Ours)
Specialist (Ours)
CT
abdomen
50
26.40
29.37
29.19
CT
bone
67
25.30
27.17
26.69
CT
cardiac
43
33.48
33.74
33.75
CT
CTA
24
31.82
35.86
35.90
CT
glass
67
29.39
24.75
24.79
CT
kidney
27
25.56
30.47
30.57
Appendix
Table 6: Per-preset PSNR (dB, test, patient means; n : patients with that preset) for the models of Tab. 2 of the main paper. Bold: best single model. Grey: one model per modality.
Source
Method
All
Base uncut
Base clipped
Clin. presets
Preset + edit
TotalSeg. MRI ( n=23 )
RenderFM
25.60
25.41
25.48
27.43
26.35
Parents only (Ours)
27.18
27.26
27.04
27.77
27.26
RenderFM-Next (Ours)
27.78
27.72
27.75
28.30
27.82
Specialist (Ours)
28.02
28.03
27.95
28.55
27.99
IXI ( n=32 )
RenderFM
26.72
27.82
25.60
28.76
26.69
Parents only (Ours)
28.60
30.05
27.47
29.18
27.48
Appendix
Table 7: MR test PSNR per source and family (dB, patient means); All as in Tab. 4 of the main paper. n : test patients; every MR test patient has preset and preset+edit frames. Grey: one model per modality.
CT
MR
Learned
Random
Learned
Random
ρ
Δ
#G
Δ
#G
ms
Δ
#G
Δ
#G
ms
10%
+0.26
0.63
+0.09
0.60
5.3
+0.63
0.30
+0.42
0.30
3.7
20%
+0.30
0.89
+0.15
0.83
6.2
+0.69
0.42
+0.49
0.42
4.4
30%
+0.32
1.16
+0.20
1.06
7.0
+0.70
0.53
+0.55
0.53
4.9
50%
+0.33
1.67
+0.26
1.51
8.7
+0.68
0.75
+0.61
0.76
6.0
Appendix
Table 8: Budget sweep (test): the values of Fig. 3 of the main paper. Δ : PSNR gain (dB) over the parents-only model; #G: rendered Gaussians (M); ms: frame time with learned selection. Parents-only model (CT / MR): 29.39 dB, 0.35 M, 4.4 ms / 27.95 dB, 0.17 M, 2.9 ms.
Method
All
Uncut
Clipped
Presets
P+edit
Cut
Fit
CT
Per-scan fit
25.34
30.70
27.68
24.08
21.80
17.02
18 m
RenderFM
26.13
26.37
26.50
26.04
25.76
17.98
–
RenderFM-Next (Ours)
28.55
29.99
29.50
27.91
28.34
20.22
–
MR
Per-scan fit
29.11
31.45
27.29
29.02
30.56
19.63
7 m
RenderFM
27.15
26.68
25.79
28.95
27.23
19.33
–
RenderFM-Next (Ours)
29.02
29.14
28.31
29.95
28.61
21.51
–
Appendix
Table 9: Per-scan fit vs. feed-forward (6 CT / 6 MR test patients, identical frames; PSNR in dB). Cut: cut-face PSNR; Fit: per-scan optimisation per patient (minutes, A100).
Photorealistic volumetric rendering of CT scans greatly benefits clinical workflows, yet neural approaches such as Neural Radiance Fields (NeRF) and 3D Gaussian Splatting (3DGS) require prohibitive per-scan optimization (hours for NeRF, about 30 minutes for 3DGS), making them impractical in clinical settings. We propose Render-FM, a feedforward model that eliminates this bottleneck by directly regressing 6D Gaussian Splatting (6DGS) parameters from a CT volume in a single 2.8-second forward pass, a 500x speedup over per-scan optimization. To bridge the domain gap between natural scene reconstruction and medical volumetric rendering, we introduce Anatomy-Guided Priming (AGP), which incorporates segmentation masks and transfer functions as structural and appearance priors, information that existing Gaussian splatting methods overlook. Built on an nnU-Net-inspired 3D U-Net trained on diverse CT scans, Render-FM predicts per-voxel 6DGS parameters and supports immediate real-time rendering. Unlike per-scan methods, it generalizes to unseen anatomies, novel transfer functions, and enables compositional organ visualization with zero additional preparation time. Optional 89-second fine-tuning further improves quality, surpassing per-scan optimized baselines. Project page: https://gaozhongpai.github.io/renderfm/.
Transfer functions (TFs) control color and visibility in medical volume rendering, but image-trained Gaussian proxies typically bake one transfer function into their appearance. We present FactorSplat, a per-scene N-dimensional Gaussian splatting (N-DGS) proxy that accepts region-specific intensity-to-RGBA curves at inference. A local lookup applies the authored color and opacity change, while a shared functional encoder and low-rank per-Gaussian factors learn the residual appearance response. Geometry and directional appearance remain shared across presets, with visibility control and TF-aware pruning preserving the ability to hide and reveal structures. On seven CT and MR scans, FactorSplat improves mean PSNR and changed-region error over region-aware VEG across validation, interpolation, unseen composition, and out-of-distribution (OOD) edits. Across these four splits, seven-scan mean PSNR gains over VEG range from 1.10 to 1.52 dB. One checkpoint per scan supports unseen edits without retraining. At 16002, the cached fast renderer averages 524 FPS with 1.17 ms TF switches. Project page: https://gaozhongpai.github.io/FactorSplat/.
Gaussian-splatting proxies enable interactive rendering of volumetric medical scans, but a clipping plane exposes anatomy not constrained by external-view training and intersects primitives that conventional splatting can only keep or drop whole. We present XClipGS (eXact Clipping), which treats these as two separate problems: the render-time clip operator and supervision of the hidden interior. Under the local affine model used by EWA splatting, the ray integral of a half-space-restricted Gaussian factorizes exactly into its ordinary 2D footprint and a conditional Gaussian CDF whose argument is affine in pixel coordinates. The resulting closed-form per-pixel operator introduces no learned clipping parameters or auxiliary network and remains differentiable with respect to the primitive and plane. We use multi-distance reference views with varied clipping-plane axes and offsets to supervise the interior through the same operator. We also introduce a paired clipped/unclipped cut-face protocol with difference-referenced cut error (CDE) and culled-side leakage (Leak), because global image metrics dilute errors near the plane. On eight CT and MRI volumes with plane offsets not used for training, XClipGS attains the highest PSNR on every volume (33.56 versus 32.34 dB for ClipGS) while rendering at over 650 FPS, far above real time, versus 278 FPS. On voxel-axis cut-face views, it raises average band SSIM from 0.809 to 0.860 and leaks roughly 40 times less. Without retraining, it also achieves the best average across all four metrics on arbitrary-normal planes; on a fixed interior, it matches RaRa's face fidelity with about 16 times less leakage. Project page: https://gaozhongpai.github.io/XClipGS/
Zhongpai Gao, Benjamin Planche, Meng Zheng +4
United Imaging Intelligence, Boston MA, USA · Clemson University, Clemson SC, USA