Remote Photoplethysmography

Also known as rPPG

Latest papers 32

5 papers in the last four weeks, level with the four weeks before. 0.0% of all new papers.

Apr 26, 2026

Intervention-Based Self-Supervised Learning: A Causal Probe Paradigm for Remote Photoplethysmography

Remote Photoplethysmography (rPPG) enables convenient non-contact physiological measurement. Existing Self-Supervised Learning (SSL) methods commonly fall into a correlation trap: they tend to learn the most dominant periodic signals in the data, such as high-energy motion or illumination noise, rather than the faint, true rPPG signal, leading to poor model generalization. To address this, we propose a new SSL paradigm, Physiological Causal Probing (PCP), which treats the latent rPPG signal as the underlying physical source and the resulting pixel chrominance variations as its visual manifestation. Its core idea is to shift from passive correlation learning to active, precise intervention: it intervenes on the video based on a proposed rPPG hypothesis, and verifies whether the post-intervention changes match physical expectations. We propose the Interv-rPPG framework to implement PCP: an rPPG extractor named PhysMambaFormer hypothesizes the rPPG signal, while a Controllable Physiological Signal Editor conducts precise chrominance-domain interventions on videos based on this hypothesis. Interv-rPPG validates the physical realism of the hypothesis through Falsifiability via Nulling' and Axiomatic Equivariance'. Our editor achieves precise editing of the rPPG signal by intervening in the low-frequency chrominance components of the video. Our method improves both in-domain and cross-domain performance on challenging datasets such as VIPL-HR and MMPD. Furthermore, it surpasses the supervised baseline in complex cross-dataset settings, while remaining competitive on clean datasets where the intervention mechanism may introduce slight residual chrominance noise. Extensive experiments, including diagnostic analysis of nuisance sensitivity, demonstrate that the PCP paradigm effectively resists motion and illumination artifacts.
Feb 27, 2026

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.