Remote Photoplethysmography

Also known as rPPG

Overview

Remote photoplethysmography studies how small changes in skin color and motion in camera footage can reveal pulse signals, heart rate, and sometimes respiration or oxygen saturation. Methods range from color-based signal processing and region-of-interest selection to deep temporal networks, self-supervised learning, and fusion of video with radar, near-infrared, or event-camera data. Researchers evaluate these approaches on video benchmarks and in settings such as driving, clinical monitoring, and egocentric sensing. A central challenge is reliable performance across motion, lighting, skin tones, compression, and new datasets, while imperfect sensor synchronization and limits on which waveform details video can recover complicate training and evaluation.

Latest papers

51 papers4 papers in the last four weeks, up 33% on the four weeks before. 0.0% of all new papers.

Nov 22, 2026

SKIA: Spatial-Knowledge Informed Attention for Robust Remote Photoplethysmography under Lower-Face Motion Artifacts

Remote photoplethysmography (rPPG) enables contactless physiological monitoring from facial videos, but facial motion, particularly mouth and jaw movements during cognitive and communicative tasks, can severely degrade signal reconstruction. We present SKIA, a lightweight, mask-guided framework that suppresses motion-prone lower-face regions while preserving physiological cues from the forehead and cheeks. Using the UBFC-rPPG benchmark, we first investigate static lower-face suppression in the classical CHROM pipeline. Static masking improves waveform Pearson correlation from 0.3507 to 0.4166 (p < 0.001) and reduces heart-rate mean absolute error (MAE) from 33.50 to 23.44 bpm. Building on this finding, we introduce SKIA-Net, a compact spatiotemporal architecture that combines raw facial frames, statically masked representations, and temporal motion differences to reconstruct blood volume pulse (BVP) waveforms. The full model achieves a Pearson correlation of 0.7522 and a heart-rate MAE of 3.73 bpm on UBFC-rPPG, outperforming single-stream variants. Ablation studies show that the static mask provides complementary information to raw appearance and that static anatomical priors outperform the tested dynamic optical-flow-based masking strategy. These results suggest that spatially informed, temporally stable masking can improve motion-robust rPPG estimation. Code: https://github.com/lee-vtruong/SKIA-rPPG
Nov 20, 2026

eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography

Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.
Nov 20, 2026

SAMA: Training-Free Consensus Ridge Tracking for Camera-Based Heart Rate on Five Public Datasets

Remote photoplethysmography (rPPG) is usually benchmarked by one heart rate per video, a figure that hides the short windows in which a tele-consultation would actually read the pulse. We present SAMA, a training-free estimator that (i) forms a quality-weighted consensus of POS and CHROM chrominance spectra, (ii) discounts frequencies occupied by pulse-free references derived from the same frames (frame motion, skin-mask geometry and background brightness), (iii) follows the heart rate through time with a Viterbi ridge under a random-walk prior, and (iv) returns a track-filtered, amplitude-normalised waveform with a per-window confidence. No parameter is learned and no dataset-specific tuning is used. On 218 recordings from 111 participants in five public datasets (UBFC-rPPG, PURE, SUMS, M3PD and a two-participant subset of MMPD), all processed with the same fixed face box and scored with a re-implementation of the rPPG-Toolbox protocol, SAMA has the lowest mean absolute error (MAE) averaged over datasets at every protocol level: 4.40 against 5.13,bpm for POS per video, 4.80 against 5.43 on 30,s windows and 5.05 against 6.59 on 10,s windows. Pooled over participants, the bootstrap interval of its paired difference from POS excludes zero on 30,s and 10,s windows (Wilcoxon p=0.11 and 0.004) but not per video, and it does not beat POS on SUMS per video or on the MMPD subset. Withholding the 20% least confident windows lowers the pooled 10,s error from 4.06 to 2.33,bpm. We also show that the per-video protocol has a floor of 1.2--1.6,bpm on datasets where heart rate drifts, and that skin tone cannot be recovered from uncalibrated video, which motivates the instrumented, skin-tone-stratified collection we propose for the Indian population. The method does not surpass the best published neural networks on UBFC-rPPG; we report where it stands against them without re-running them.
Nov 10, 2026

Pulse or Provenance? What rPPG-Based Deepfake Detectors Learn

Remote photoplethysmography (rPPG) has been proposed as a physiological cue for deepfake detection, based on the premise that synthesized faces lack a genuine cardiac signal. We examine what rPPG-style detectors learn on Celeb-DF++ (22 forgery methods) and FaceForensics++ (FF++), using one identically sampled window per real and fake video. On talking-face forgeries, simple chrominance traces reach an AUC of 0.998, exceeding a dedicated rPPG extractor (0.87). Controlled experiments indicate that this signal is not physiological in origin. On fully synthesized forgeries, it is equally discriminative when extracted from background regions or from full frames without face detection, and it is concentrated above the 0.7 to 4 Hz heart-rate band. It is largely removed by shuffling frame order but persists after normalizing resolution, frame rate and encoding, and an independent reimplementation reproduces these findings. Removing high-frequency content makes most synthesized videos appear real, adding it makes real videos appear fake, and injecting a synthetic pulse has little effect. In controlled self-reenactment experiments with two generators, animating a face from a single frame introduces the same high-frequency signal, whereas reconstructing each frame from its own source does not. Face-based chrominance detectors trained on Celeb-DF++ classify over 99% of real FF++ videos as fake, indicating that they largely encode video source rather than manipulation, and a CLIP-based detector exhibits the same behavior. A frozen CLIP backbone matches or exceeds fusions of CLIP with rPPG and frequency features. Finally, we show that the official Celeb-DF and Celeb-DF++ splits share identities and source-video content between training and test, and that custom protocols reusing test videos and identities in training inflate weaker detectors by up to 0.30 AUC.
Oct 13, 2026

Why Do VLMs Fail at Remote Physiological Measurement? Rethinking with Physiological Grounding and Numerical Alignment

Video-based remote physiological measurement (RPM) has broad applications, while Vision-Language Models (VLMs) provide a promising opportunity to enable end-to-end physiological monitoring for future human-aware intelligent systems. However, existing RPM methods rely on task-specific models and cannot be seamlessly integrated with the multimodal understanding and interaction capabilities of VLMs. We revisit RPM with VLMs and provide empirical evidence for two major bottlenecks: generic visual semantic representations fail to preserve fine-grained physiological cues; while discrete token prediction in autoregressive generation is inherently misaligned with continuous numerical measurement. To address these challenges, we propose VITAL (Visual-physiological Token Alignment for Language Models), a visual-physiological token alignment framework for RPM and preserving general vision tasks. VITAL retains the original visual pathway for semantic understanding and introduces an independent physiological pathway to jointly model semantic and physiological information. Moreover, we propose a structured numerical alignment approach to improve the reliability of generative heart rate estimation by enhancing numerical relationship modeling. Extensive experiments show that VITAL improves cross-domain estimation performance on multiple rPPG datasets while preserving the general visual understanding capability of VLMs, demonstrating its effectiveness as a unified visual-physiological model. Code will be released.
Sep 30, 2026

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose FLOW (Feature-Level Optimal Warping), an optimal transport--driven framework for domain-generalized rPPG. FLOW integrates a Temporal Refinement Module (TRM) to stabilize temporal dynamics and a Prototype-based Cross-Temporal Optimal Transport (PCOT) module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.
Sep 29, 2026

Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG

Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.
Sep 22, 2026

Heartian: Physiology-Aware Relightable Gaussian Head Avatar

Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose Heartian, a physiology-aware modulation framework that learns cardiac-cycle-dependent per-frame albedo modulation of facial skin-region Gaussians within a relightable head avatar to encode remote photoplethysmography (rPPG) signals. Using synchronized contact PPG supervision, Heartian models the prescribed cardiac waveform as the sum of two Gaussian functions and learns per-frame spatial residuals via a lightweight MLP. Across 152 stationary recordings from UBFC-rPPG, PURE, and MMPD, attribute-space recovery of the supplied signal achieves a pooled recording-level heart-rate MAE of 0.29 bpm and MAPE of 0.38%. The signals remain detectable after rendering by benchmark rPPG methods, with the best tested configuration - a motion-augmented TS-CAN decoder pretrained on UBFC-rPPG - recovering heart rate from the rendered MMPD avatars at 0.97 bpm MAE and 1.21% MAPE. Meanwhile, Heartian maintains reconstruction quality comparable to the baseline, with negligible average PSNR degradation of 0.005 dB. Overall, our work embeds recoverable rPPG signals as controllable material attributes to subject-specific Gaussian head avatars while retaining the reconstruction quality.
Sep 11, 2026

Beyond Ambiguous Visual Cues: Studying Physiological Disruptions and Cross-Modal Inconsistencies in Deepfake Videos

Recent deepfake detection studies increasingly suggest remote photoplethysmography (rPPG) signals as an authenticity cue. However, existing benchmarks lack physiological ground truth, and current detectors underexplore the cross-level relationship between facial features and physiological dynamics, often relying on late fusion or rPPG features alone. In this paper, we construct high-fidelity deepfake manipulations on established real rPPG datasets (COHFACE and UBFC-rPPG) to investigate how forgeries disrupt natural physiological signals and facial behavior at the same time. Building on this analysis, we propose a bidirectional co-attention fusion detector that jointly models rPPG and facial behavior tokens. This mechanism explicitly captures the cross-level dependencies between pulse dynamics and facial motion to learn a robust, joint authenticity representation. Extensive experiments using a subject-disjoint 5-fold evaluation demonstrate the superiority of our approach. Achieving a 92.80% AUC on constructed datasets using face swapping and 96.78% AUC on motion transfer, our model outperforms both the rPPG-only single modality baseline and the best feature-level fusion methods. Furthermore, transfer-learning result of the fusion detector on Celeb-DF-v2 while keeping both feature extractors fixed achieves 91.20% accuracy and 86.08% AUC, which suggests applicability under target-domain adaptation.
Sep 9, 2026

Beyond Contact Sensors: Deep learning with Pseudo-Labeling for remote Photoplethysmography

Heart rate is a critical biomarker of health, and remote photoplethysmography (rPPG) enables its contactless estimation from video data for telemedicine applications. Recent advancements in deep learning based rPPG methods achieve state-of-the-art results, outperforming classical signal-processing methods in complex scenarios. However, deep learning methods depend on datasets with precise synchronization between videos and ground truth signals collected via contact sensors, whereas signal-processing-based methods do not. To address this dependence on labeled datasets, which are labor-intensive to collect, we investigate under which circumstances pseudo-labels extracted using unsupervised signal-processing methods can replace contact sensors labels for training deep learning methods. Our systematic evaluations found that for datasets with imperfect synchronization, the pseudo-label approach outperforms supervised training on contact sensors. For datasets with good synchronization, results are mixed: within-dataset evaluation shows no significant difference between training methods, while cross-dataset evaluation favors supervised training. However, removing a single outlier participant significantly improves the pseudo-label approach's cross-dataset performance, highlighting the importance of label quality. These results demonstrate that signal-processing methods can generate valid training signals for deep learning models, reducing dependency on labor-intensive dataset collection while maintaining competitive performance.
Sep 3, 2026

Cross-Dataset Transfer and Reliability of Explainable Artificial Intelligence for RhythmFormer Remote Photoplethysmography

Background. Remote photoplethysmography estimates the cardiovascular pulse from facial video, and its explanations have rested on inspecting heatmaps rather than on quantitative evidence about where a model reads it. We quantified the explanations and asked whether such explanations transfer between datasets and track model performance. Method. We trained eight condition-specific RhythmFormer models on NCKU-rPPG, recorded under three illumination levels, speaking, rotation, and cycling, estimated one heart rate per 5.12-second clip, and set them beside a UBFC-rPPG reproduction. Raw attention, rollout, attention flow, and Beyond Intuition were assessed by skin coverage and the Salience-guided Faithfulness Coefficient (SaCo). Results. Beyond Intuition ranked highest on both datasets, at median coverage 0.789 and SaCo 0.837 on Static level 3 against 0.826 and 0.917 on UBFC-rPPG; lower ranks differed. Within one participant of one condition, neither measure was related to a clip's heart-rate error, waveform correlation, or signal-to-noise ratio on either dataset: 186 of the 252 coefficients fell below ∣ρ∣=0.10|ρ|=0.10 and 28 reached p<0.05p<0.05 against the 13 expected by chance. Across the eight scenarios only Beyond Intuition's coverage followed the three performance measures, at ρ=−0.43ρ=-0.43, +0.57+0.57, and +0.43+0.43, while the attention-only methods' SaCo ran opposite to each. It failed at 40 lux alone, its median coverage falling to 0.180 and its median SaCo to −0.178-0.178, whereas motion degraded the estimates far more without such a drop. Conclusions. Skin coverage and SaCo carry information complementary to the performance measures rather than a proxy for them: attributing to the skin does not guarantee an accurate estimate. What an attribution reveals about a condition is where the model looks rather than how faithfully its map is ordered.
Aug 30, 2026

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.
Aug 27, 2026

Property-Specific Recoverability from Contact PPG to Camera rPPG under Heterogeneous Observation Conditions

Camera-derived remote photoplethysmography (rPPG) is commonly validated through endpoint accuracy, but endpoint performance does not establish whether other physiological properties of source contact photoplethysmography (PPG) remain preserved recording by recording. We evaluated property-specific PPG-to-rPPG recoverability on 655 recordings from the Multi-Domain Mobile Video Physiology Dataset using CHROM as a fixed camera-rPPG observation pathway. The pathway reproduced the published CHROM correlation regime, with heart-rate MAE of 15.26 bpm and Pearson correlation of 0.0801. Matched-versus-shuffled validation revealed modest recording-specific autocorrelation correspondence, while spectral and recurrence-rate measures showed little matched discrimination. Maximal Lyapunov exponents showed essentially no recording-specific PPG-to-rPPG correspondence, with correlation of 0.0231 and permutation p-value of 0.5584, despite population-level overlap. Endpoint discrepancy exhibited Fitzpatrick-associated heterogeneity after adjustment for lighting and motion, including a Fitzpatrick VI versus III contrast of 9.32 bpm, while dynamical discrepancy showed no corresponding gradient. Aggregate RGB signal-to-noise ratio did not materially account for the endpoint contrast. In subject-held-out analysis, adding motion and lighting consistently reduced MAE across linear, ridge, and random-forest learners relative to rPPG-HR-only calibration, with reductions up to 13.32 percent. These findings show that recoverability is property-specific: physiological properties differ in recording-specific preservation and dependence on observation conditions, and population-level plausibility does not establish preservation of individual recordings.
Aug 19, 2026

EgoHRV: Continuous Heart Rate Variability Estimation from Egocentric Systems for Autonomic Response and Skill Assessment

Egocentric vision systems capture human behavior from visible cues, but overlook physiological indicators of autonomic states such as stress, engagement, and attention. Heart rate variability (HRV) is a widely used noninvasive marker of autonomic regulation under stress. HRV reflects small timing differences between successive heartbeats and has so far been out of reach for egocentric platforms, where motion and noise in gaze video mask exactly this fine-grained timing. We propose EgoHRV, a method that estimates HRV as well as heart rate (HR) from the gaze cameras that are already integrated into egocentric headsets. Our pipeline combines a 3D backbone with a novel low--high decomposition module that extracts the blood volume pulse (BVP) signal from gaze video. Our cross-domain pretraining aligns the frequency-domain representations of contact-based and camera-derived signals. This alignment gives EgoHRV the temporal precision to recover HRV from the subtle fluctuations in gaze video. EgoHRV achieves state-of-the-art accuracy for HR and HRV estimation from egocentric video, and its uncertainty-aware design improves downstream behavioral modeling. Integrating our HRV estimates and confidence measures into EgoExo4D's proficiency estimator raises accuracy by 17.8%. Beyond skill, continuous HRV estimation also opens egocentric systems to stress- and arousal-aware estimation tasks. Code: https://github.com/eth-siplab/EgoHRV
Aug 16, 2026

CardiacMamba: Fair and Robust RGB-RF Fusion for Remote Heart Rate Estimation via State Space Modeling

Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions
Jul 29, 2026

PhysAgent: A Multi-Agent Framework for Reliable Remote Heart Rate Estimation

Remote photoplethysmography (rPPG) enables non-contact heart-rate estimation from facial videos, but its weak physiological signal is easily corrupted by motion, illumination changes, occlusion, skin-appearance variation, and device noise. Existing rPPG methods typically rely on a single model to directly predict heart rate or recover pulse waveforms, while different strong estimators may produce conflicting yet individually plausible candidates for the same video. To resolve these conflicts, we propose PhysAgent, an inference-time multi-agent candidate-verification framework. Unlike direct prediction approaches, PhysAgent neither trains a new base rPPG model nor asks Multimodal Large Language Models (MLLMs) to output heart rate directly. In contrast, it treats outputs from multiple base estimators as physiological hypotheses to be verified and uses a lightweight 4B MLLM, Qwen3-VL-4B, to drive multi-agent reasoning over video conditions, signal reliability, and candidate disagreement. A deterministic physiological verifier checks the fusion proposal, and a reproducible numerical fusion process produces the final heart rate. Experimental results on multiple public rPPG benchmarks show that PhysAgent improves fusion stability and reliability across different datasets and source-domain settings, while avoiding the irreproducibility and physiological inconsistency of direct MLLM prediction or unconstrained ensemble fusion. The code will be released soon.
Jul 23, 2026

PulseGuard: rPPG-Derived Temporal Signals as a Forensic Modality for Talking-Face Deepfake Detection

Talking-face (TF) deepfake generation synthesizes photorealistic facial video from a static source image and an audio signal, producing forgeries that current image-based detectors consistently fail to identify. Unlike face-swap manipulation, TF synthesis has no underlying real video from which to inherit physiological characteristics, motivating remote photoplethysmography (rPPG) as a detection modality for this forgery category. We propose PulseGuard, a detection framework that extracts per-window rPPG waveforms via RhythmFormer and trains a suite of lightweight classifiers to distinguish real from synthesized traces. Evaluated on the TF subset of Celeb-DF++ under a strict subject-independent protocol, where test identities are completely separated from training identities, our 1D ResNet achieves a window-level AUC of 0.826 at EER 25.1% (0.842 pooled to video level, the granularity at which DeepFakesON-Phys is scored) while operating exclusively on the extracted temporal signal, and retains AUC 0.754 on generators withheld entirely from training. We document a controlled reproduction study of DeepFakesON-Phys, the representative prior rPPG detector, demonstrating degradation from AUC 0.999 on legacy face-swap data to 0.576 on the TF subset of Celeb-DF++. We further show that detection difficulty is strongly method-dependent: AUC ranges from 0.937 (Real3DPortrait) to 0.617 (IP-LAP) across the seven TF generators, with the ordering broadly preserved under per-method training. This spread is stable across training regimes rather than reflecting evaluation noise, and constitutes the primary empirical contribution of the work. We report these as empirical baselines and do not establish that the discriminative content is cardiac in origin.
Jul 17, 2026

CanonicalPhys: Pose-Robust Remote Photoplethysmography via Canonical-Space Priors

Deep remote photoplethysmography (rPPG) attains sub-bpm heart-rate error on frontal, stationary faces yet degrades sharply under head pose: on MMPD, the state-of-the-art FactorizePhys backbone's MAE grows 1.60×1.60\times from frontal (∣yaw∣<15∘|\text{yaw}|{<}15^\circ) to large-yaw (∣yaw∣≥45∘|\text{yaw}|{\geq}45^\circ) frames. We argue that pose is a coordinate-structural nuisance rather than a data-augmentation problem: in image coordinates the same pixel maps to different anatomy at different poses, blocking three priors otherwise natural for rPPG, namely the dichromatic reflection model, pulse-phase invariance across skin regions, and the POS/CHROM chromaticity projection, each of which presumes a stable anatomy-to-pixel mapping. We introduce CanonicalPhys, which prepends a differentiable four-point homography that fixes four facial anchors at canonical positions; in this canonical frame the three priors become expressible as a per-pixel Lambertian weight, a cross-ROI temporal consistency loss, and knowledge distillation from windowed POS, none of which adds trainable parameters over the backbone. At an identical parameter count, CanonicalPhys reduces MMPD's frontal-to-large-yaw MAE degradation from 1.60×1.60\times to 1.33×1.33\times and flattens the mild-yaw bin from 1.32×1.32\times to 1.07×1.07\times (across CanonicalPhys variants), with matched cross-dataset MAE reductions of up to 32%32\% on pose-rich targets. Code: https://github.com/infraface/CanonicalPhys
Jul 6, 2026

Non-contact, Real-time, Heart-rate Measurement using Image Processing with Commodity Cameras and AI Agents

Heart rate measurement is one of the key requirements for real-time health monitoring, in particular for health caring of elderly people. Traditional heart rate measurement relies on contact sensing mechanisms such as some heart rate measurement devices at medical hospitals or some wearable devices with embedded sensors such as Apple Watch, etc. In this paper, we develop a system for non-contact, real-time, heart rate measurement using image processing with commodity cameras such as an embedded camera on a laptop, where we use an innovative algorithm to capture the relevant signals for the computation of heart rate in a time series in real life environments. The presented heart rate computation (HRC) process is composed with four major steps: (a) identify frames per second of the camera in use, i.e., 30 frames per second for a given camera, (b) face detection (FD) with shape predictor of 68 face landmarks using deep learning (DL) method, (c) time sliding window (TSW) algorithm to de-noise the signal by smoothing out the noise, and (d) compute heart rate based on identified signal periodicity. We test and analyze the developed prototypes against heart rate results by Apple Watch and check the difference range in multiple rounds and compute the mean of the difference for the measurement values of the heart rate of the same person at the same time. We will do further tuning and optimization of the present methods and deploy the system as a personal AI agent [6] for health monitoring as our future directions.
Jun 30, 2026

Rhythm-Structured Predictive Learning for Remote Photoplethysmography

Remote photoplethysmography (rPPG) estimates physiological signals from facial videos by analyzing subtle pulse induced skin color variations. Despite recent progress, existing self-supervised rPPG methods mainly reconstruct masked pixels or low-level visual representations, which can bias the model toward facial appearance rather than latent physiological dy namics. Moreover, most recent Mamba-based approaches scan facial video tokens only in chronological order, limiting their ability to exploit the cyclic structure of pulse signals. To ad dress these limitations, we propose RhythmJEPA, a rhythm structured joint-embedding predictive learning framework for rPPG. Instead of reconstructing RGB frames, RhythmJEPA predicts latent teacher representations from masked facial videos, thereby encouraging physiology-aware representation learning in the embedding space. To explicitly model pulse-related tem poral structure, we introduce a Cyclic Rhythm-State Plan ner (CRSP), which estimates frame-wise latent physiological states and decodes the most plausible cyclic state path via dynamic programming with a constrained transition grammar. Guided by the decoded states, we further design a Dual Order Mamba Encoder (DOM), which combines conventional chronological scanning with state-ordered scanning to capture both local temporal continuity and long-range rhythm-consistent dependencies. Finally, a lightweight Spatial Pulse Mixer (SPM) extracts compact pulse-sensitive facial tokens with a favorable balance between complexity and performance. Experiments on PURE, UBFC-rPPG, and MMPD show competitive performance over representative rPPG methods. The codes are available at https://github.com/deconasser/RhythmJEPA.
Jun 26, 2026

RPM-Distill: Physiology-guided Adaptive Cross-modal Distillation for Robust Remote Physiological Measurement

Video-based remote physiological measurement (RPM) is highly accessible but remains fragile under varying illumination, skin tones, and motion. Radio frequency (RF) radar is largely invariant to illumination and appearance, providing complementary cardio-respiratory micro-motion cues; however, requiring radar at inference is often impractical due to its limited ubiquity and deployment overhead. We propose RPM-Distill, a physiology-guided cross-modal distillation framework that leverages synchronized radar only during training while retaining video-only inference. Our key observation is that although RGB and RF waveforms differ in sensing physics and time-domain morphology, they share similar latent periodic rhythm in the frequency domain. We thus distill physiology-structured spectral evidence to improve robustness, via losses that (i) anchor the fundamental peak, (ii) match the off-peak background distribution, and (iii) preserve spectral morphology and sharpness. To avoid negative transfer under sample-level teacher quality and alignment uncertainty, a spectral policy network predicts sample-level distillation gates and component weights from the student--teacher spectral relation map, learned with a meta bilevel objective on a small labeled validation split. Through extensive experiments in challenging conditions and cross-dataset settings, RPM-Distill brings 81% MAE and 21% correlation improvement over unimodal baselines. Code is at https://github.com/WJULYW/RPM-Distill.
Jun 22, 2026

PhysFlow: Frequency Decoupled with Dual-Field Rectified Flow for Remote Photoplethysmography

Remote Photoplethysmography (rPPG) enables contactless pulse estimation from facial videos, serving as a vital tool for health monitoring. However, current deep learning methods often struggle under complex disturbances, particularly varying illumination, facial expressions, and unconstrained head movements. In such scenarios, subtle physiological signals are easily dominated by external interference, making the recovered rPPG waveform unstable and unreliable. One important reason is that most existing methods directly model the rPPG signal in a unified manner, where different signal components are coupled during reconstruction. This makes it difficult to preserve weak pulse-related variations when strong disturbance-induced changes are present. To address this challenge, we propose PhysFlow, a frequency-decoupled dual-field rectified flow framework tailored for robust rPPG estimation. Specifically, the ground-truth rPPG signal is decomposed into trend and amplitude components, which are used as separate supervisory targets. Based on the extracted facial features, PhysFlow learns two component-specific conditional velocity fields to model the two components separately. This design reduces mutual interference between different components and improves the robustness of rPPG reconstruction under complex disturbances. Moreover, the rectified flow formulation enables efficient waveform reconstruction with only a few ordinary differential equation (ODE) integration steps. Extensive experiments on multiple benchmark datasets demonstrate that PhysFlow outperforms state-of-the-art methods in both heart-rate estimation and rPPG waveform reconstruction across diverse challenging scenarios.
Jun 22, 2026

StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning

Remote photoplethysmography (rPPG) estimates the blood volume pulse (BVP) signal from facial videos, enabling contact-free health monitoring. Conventional clip-wise approaches, which use video clips as input, require capturing over one hundred frames before inference, thus introducing several seconds of delay and hindering real-time use. Meanwhile, frame-wise approaches struggle to capture long-range temporal and periodic features of physiological rhythms, and therefore lead to reduced estimation accuracy. To overcome these issues, we propose StreamPPG, a unified architecture that enables low-latency frame-wise physiological signal estimation while achieving competitive accuracy compared with clip-wise approaches. StreamPPG is trained under a consistent privileged learning (CPL) strategy, which leverages ground-truth rPPG signals as privileged information to enhance the model's representation capability. Extensive experiments demonstrate that StreamPPG achieves state-of-the-art accuracy across multiple datasets while maintaining real-time throughput on edge devices.
Jun 19, 2026

A Skin-Tone-Aware Dual-Representation Remote Photoplethysmography Framework for Contactless Respiratory Rate Estimation

Respiratory rate is a vital indicator of pulmonary and cardiovascular health, yet conventional methods for estimating respiratory rate are often intrusive due to their contact-based nature. Remote photoplethysmography offers a promising non-contact alternative and has been widely used for heart rate estimation; however, its potential for respiratory rate estimation remains underexplored. Existing methods typically adapt green and chrominance-based projections originally designed for heart rate estimation, which only partially capture respiratory dynamics. Most prior work focuses on the Eulerian representation with fixed or empirically selected RGB projections. To address these gaps, we propose a skin-tone-aware dynamic RGB signal projection that captures respiratory information. To mitigate the sensitivity of the Lagrangian representation to non-respiratory motion, we introduce a denoising network for motion-based remote photoplethysmography signals. We further design a phase-independent contrastive loss that enables Eulerian and Lagrangian representations to collaboratively learn respiratory rate information. We also introduce RR-rPPG, a respiratory-rate facial video dataset with Indian demographic representation. We evaluate the method on RR-rPPG and the publicly available COHFACE dataset, where it consistently outperforms comparison methods and achieves up to a 42.1% reduction in mean absolute error across the evaluated settings. The proposed framework demonstrates the effectiveness of jointly leveraging skin-tone-aware Eulerian and denoised Lagrangian representations for contactless respiratory rate estimation from facial videos. In addition, RR-rPPG contributes a diverse benchmark resource for future research in remote respiratory monitoring. The code and dataset will be made publicly available upon paper acceptance.
Jun 19, 2026

MS-rPPG: Multi-spectral State Space Model for Remote Photoplethysmography in Driver Monitoring Systems

Remote photoplethysmography (rPPG) is a camera-based technique for measuring physiological signals, particularly cardiac activity. From the remotely measured signals, heart rate can be estimated, which is crucial for health monitoring. In this study, we investigate a driver health monitoring system based on remote heart rate estimation. However, driving environments represent uncontrolled settings where videos are subject to varying illumination conditions and frequent head movements. We introduce MS-rPPG, a multi-spectral framework that combines RGB with near-infrared (NIR) face video to alleviate rPPG estimation under challenging driving conditions. To combine the complementary features from two spectral videos, we propose a cross-spectral linear modulation (CSLM) strategy based on frequency-domain analysis. Moreover, we introduce MS-Mamba, a novel state space model designed to effectively model long-range temporal dependencies while jointly capturing cross-channel interactions between multi-spectral features. We collected a real-world dataset called MS-Drive, which was recorded from 50 participants while driving the vehicle. The proposed method was evaluated on the MR-NIRP Car dataset and MS-Drive datasets. The experimental results indicate that MS-rPPG shows better robustness and heart rate estimation accuracy than previous methods, highlighting its promise for driver health monitoring. The codes are available at github.com/ziiho08/MS-rPPG.
Jun 14, 2026

Fusion-E2Pulse: A Multimodal Event-RGB Fusion Network for Non-contact Pulse Wave Reconstruction

Non-contact pulse wave reconstruction hinges on the precise recovery of waveform morphology, including the dicrotic notch. Conventional Red-Green-Blue (RGB)-based methods, which extract physiological signals from recorded facial videos, are constrained by the integral imaging mechanism of standard cameras, where the exposure process induces a smoothing effect that attenuates subtle vascular pulsation details. Conversely, neuromorphic event cameras, while offering exceptional sensitivity to intensity fluctuations, are inherently susceptible to noise and artifacts induced by minor motion. To exploit the synergy between frame-based integration and event-based differential sensing, we propose a novel multimodal network named Fusion-E2Pulse. This framework utilizes filtered RGB signals as structural priors to suppress motion artifacts, while leveraging the high-sensitivity of event streams to recover fine-grained morphological details. Experimental results demonstrate that Fusion-E2Pulse achieves state-of-the-art performance, effectively balancing noise suppression and morphological fidelity, achieving a mean absolute error of 0.78 bpm for heart rate estimation, a waveform correlation of 0.89, and a systolic phase duration error of 16.74 ms, validating its efficacy in reconstructing fine-grained pathological features.
Jun 11, 2026

Explaining RhythmFormer: A Systematic XAI Analysis of Periodic Sparse Attention for Remote Photoplethysmography

Remote photoplethysmography (rPPG) transformers achieve low heart-rate error on benchmarks, yet their decisions remain opaque--a growing concern as rPPG moves toward clinical heart rate estimation. Existing rPPG XAI is dominated by qualitative heatmap inspection without quantitative faithfulness metrics or physiology-grounded validation, leaving a gap between visual plausibility and auditable evidence. We address this gap. First, we adapt four attribution methods (raw attention, rollout, flow, Beyond Intuition) to RhythmFormer's bi-level routing attention with top-kk selection. Second, we introduce a skin coverage metric quantifying how much attribution mass falls on skin regions. Third, we adapt the SaCo faithfulness coefficient from its original classification setting to rPPG regression by using the MAE between original and perturbed predicted rPPG waveforms as the perturbation impact. Applying these tools, we quantify a multi-hop leakage effect under sparse top-kk routing: attention rollout and flow almost completely restores the connections that individual refined-attention layers explicitly set to zero. Beyond Intuition mitigates this via its value-projection-weighted rollout and gradient-supported mask, attaining the highest median refined skin coverage (0.830.83 vs. 0.570.57 for vanilla rollout) and faithfulness (F=0.92F=0.92) among the evaluated methods on UBFC-rPPG. Validation across diverse datasets and model variants is needed. A case study on a low-SaCo outlier further shows all four methods recovering consistently once an artefactual region is replaced, suggesting consistent SaCo behavior across attribution families in this illustrative case. Together, these metrics move XAI for rPPG toward auditable numerical evidence about spatial alignment and perturbation faithfulness, i.e. trustworthy rPPG XAI.
Jun 10, 2026

Illumination-Robust Camera-Based Heart-Rate Estimation for Physiological Sensing in Robots

Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight (β\mathbfβ) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that β=5\mathbfβ=5 provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Jun 2, 2026

Spatial Artifact Coherence Determines Codec Robustness in Patch-Based rPPG

Remote photoplethysmography (rPPG) achieves low heart-rate error on uncompressed benchmarks yet is deployed over compressed video channels in telehealth, neonatal ICU, and driver fatigue applications. No prior work identifies the physical quantity determining when spatial decomposition outperforms global-projection methods under codec compression. We propose Spatial Artifact Coherence (SAC), defined as the ratio of off-diagonal to diagonal energy in the 4x4 inter-patch Green-channel covariance matrix (bandpass 0.75-2.5 Hz), and the PatchPCA algorithm family (four codec-aware rPPG algorithms). We evaluate 280 subjects across three public datasets, 11 codec degradation variants (MPEG-4, H.265, H.264, JPEG, chroma subsampling), and 13 algorithms via Wilcoxon tests (BH-FDR, q < 0.05, 904 tests). SAC explains 93.8% of between-variant variance in PCA advantage (r = +0.969), with zero overlap between codec families: non-MPEG-4 variants cluster at SAC 0.10-0.18 with 84-90% PCA win rates, while MPEG-4 variants cluster at SAC 0.48-0.59 with 61% win rate and a 5.8x reduction in mean improvement. Within subjects, 78% confirm the expected pattern (p < 10^-22, dz = 0.73). Within-variant subject-level SAC correlation is r = +0.099, confirming SAC classifies codec families rather than predicting individual outcomes. MPEG-4's effect is structural (macroblock DCT geometry, not noise amplitude), governed by source codec state, not resolution. P-Hybrid is identified as the most deployment-robust algorithm. Two necessary operating conditions for PatchPCA advantage are established: SAC < 0.30 and low-to-moderate motion, directly ruling out raw-to-MPEG-4 transcoding pipelines. SAC provides a physically grounded metric for codec-aware rPPG algorithm selection in clinical remote monitoring systems.
Jun 2, 2026

Template Collapse and Information-Theoretic Limits in Camera rPPG Pulse Morphology Restoration

Objective: Consumer face camera remote photoplethysmography (rPPG) enables passive cardiovascular monitoring, but whether single-cycle waveform morphology encoding arterial stiffness biomarkers is recoverable from this measurement has not been characterised. Methods: We evaluated 16 architectures spanning six families on 153 subjects across three datasets, introducing cross-subject Pearson r to distinguish subject-specific recovery from template collapse. Results: No architecture recovered subject-specific morphology (cross-subject r range 0.773--0.9999; ground-truth ceiling 0.601). Supervised Contrastive (SupCon) converged to log N = 4.844, constituting the strongest available empirical evidence that no discriminative morphological structure is extractable from single-cycle rPPG by the encoder families tested. The VAE decoder restores population-level harmonic content absent from the rPPG input (H2/H1: 0.310 output vs. 0.275 input), generalising zero-shot to UBFC (r = +0.708); a directional hallucination gap (p = 0.150) suggests partial signal reading. Anti-collapse objectives fail when input carries no discriminative structure. Significance: Consumer cameras cannot encode individual arterial morphology; cross-subject r is a necessary collapse diagnostic for waveform reconstruction benchmarks.