cs.CVSep 15, 2025

End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRI

Authors: Yihong ChenJiancheng YangDeniz Sayin MercadierHieu LeJuerg SchwitterPascal Fua

Organizations: School of Computer and Communication Science, EPFL · ELLIS Institute Finland, Aalto University, Finland · University of North Carolina at Charlotte · Center for Interventional MRI, CHUV

Abstract

Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.

Explore similar work

May 13, 2026cs.CV

CineMesh4D: Personalized 4D Whole Heart Reconstruction from Sparse Cine MRI

Accurate 3D+t whole-heart mesh reconstruction from cine MRI is a clinically crucial yet technically challenging task. The difficulty of this task arises from two coupled factors: inherently sparse sampling of 3D cardiac anatomy by 2D image slices and the tight coupling between cardiac shape and motion. Current cardiac image-to-mesh approaches typically reconstruct only a subset of cardiac chambers or a single phase of the cardiac cycle. In this work, we propose CineMesh4D, a novel end-to-end 4D (3D+t) pipeline that directly reconstructs patient-specific whole-heart mesh from multi-view 2D cine MRI via cross-domain mapping. Specifically, we introduce a differentiable rendering loss that enables supervision of 3D+t whole-heart mesh from multi-view sparse contours of cine MRI. Furthermore, we develop a dual-context temporal block that fuses global and local cardiac temporal information to capture high-dimensional sequential patterns. In quantitative and qualitative evaluations, CineMesh4D outperforms existing approaches in terms of reconstruction quality and motion consistency, providing a practical pathway for personalized real-time cardiac assessment. The code will be publicly released once the manuscript is accepted.
Xiaoyue Liu, Xiaohan Yuan, Mark Y Chan +2
Jul 2, 2026cs.CV

Personalized 4D Whole-Heart Mesh Reconstruction from Cine MRI via Multi-Scale Temporal Modeling and Differentiable Contour Rendering

Accurate 4D whole-heart mesh reconstruction from sparse cine MRI is critical for creating cardiac digital twins, but remains challenging due to limited 2D slice coverage and the complex coupling between cardiac shape and motion. Existing methods often rely on intermediate contour fitting and typically reconstruct static, single-phase, or partial cardiac geometries, limiting their ability to capture full-chamber dynamics. We propose a novel end-to-end framework for reconstructing temporally resolved whole-heart meshes from multi-view 2D cine MRI sequences by learning an image-to-mesh mapping. The framework incorporates a differentiable contour renderer inspired by the Beer-Lambert attenuation principle, enabling anatomy-aware supervision of 3D+t mesh deformation through contour-based projection losses. To improve temporal consistency across the cardiac cycle, we further introduce a multi-scale temporal modeling module that integrates global cycle-level dynamics with local inter-frame coherence to generate smooth and physiologically plausible mesh trajectories. The proposed method achieved a whole-heart mean absolute error of 1.68 ±\pm 0.31 mm and a motion jitter of 0.77 ±\pm 0.17 mm/frame3\mathrm{mm}/\mathrm{frame}^{3}, outperforming existing methods with lower reconstruction error and substantially improved motion smoothness. It also improved 2D contour alignment across multiple cine MRI views and supported downstream proof-of-concept electrophysiological simulation. The code will be released publicly upon acceptance of the manuscript for publication.
Xiaoyue Liu, Dongcheng Cang, Xiaohan Yuan +3
Jul 8, 2026cs.CV

Bi-PT: Bidirectional Cross-Attention Point Transformers for Four-Chamber Heart Reconstruction from Sparse Cardiac MRI Data

We propose Bi-PT, a pipeline for reconstructing 3D four-chamber human heart meshes from clinical sparsely sampled cardiac magnetic resonance imaging (CMR) data. This work addresses the error-prone generation of 3D cardiac shape from a sparse point cloud (SPC) extracted from 2D long-axis and short-axis views used in routine clinical CMR protocols. Bi-PT enables accurate inference of the four-chamber heart mesh from the SPC by learning robust point features via bidirectional point cross-attention between an atlas and the SPC, together with per-point semantic labels that improve correspondence estimation. We formulate the deformation field as a Neural Ordinary Differential Equation (NODE) parameterized by a per-point affine transformation and translation to deform the atlas toward the target heart shape. By learning such a NODE, we can guarantee the deformation field to be a locally affine diffeomorphic deformation. We also integrate a semantic label loss into the Chamfer distance to encourage label-consistent correspondences and add a smoothness regularization to stabilize and improve the learning of the deformation field. Extensive experiments demonstrate that Bi-PT achieves accurate and robust performance compared to baselines.
Chenchuhui Hu, Shaoming Pan, Leon Axel +1