Public datasets of Chest X-Rays (CXRs) have long been a popular benchmark for developing machine learning (ML) computer vision models in healthcare. However, the reported strong average-case performance of these models do not necessarily reflect their actual utility when used in heterogeneous clinical settings, potentially masking weaker performance in medically significant scenarios. In this work we use clinical context to provide a more holistic evaluation of models for CXR diagnosis. In particular, we use discharge summaries, recorded prior to each CXR, to derive a ``pre-CXR'' probability of each CXR label, as a proxy for existing contextual knowledge available to clinicians when interpreting CXRs. We use this measure to probe model performance along two dimensions: First, using a stratified analysis, we show that models tend to have lower performance (as measured by AUROC and other metrics) among individuals with higher pre-CXR probability. Second, by controlling for pre-CXR probability via matching and re-weighting, we demonstrate that performance degrades when the correlation is broken between prior context and the current CXR label, suggesting that model performance is highly sensitive to the underlying distribution of clinical context. Specifically, cases with high pre-test probabilities present a fundamentally more difficult visual classification task, highlighting a gap in clinical utility when models are applied to high-risk cohorts.
Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment. However, commonly used report-derived labels for pathology classification or generic image quality metrics for reconstruction may not reliably reflect clinical judgment. We systematically investigate how evaluation-reference choices affect model performance and ranking in both pathology classification and image quality assessment (IQA). To enable controlled comparison across evaluation references, we collected paired expert image- and report-derived labels for thoracic findings from a clinical cohort at Cambridge University Hospitals (CUH) and curated a subset of the public MIMIC-CXR dataset, along with expert ratings of diagnostic image quality. We show that for supervised image classifiers (ResNet, DenseNet), several zero-shot and fine-tuned vision-language models (e.g., MedKLIP, GLoRIA, and ConVIRT), changing the label source leads to substantial differences not only in performance estimates but also in model rankings. In parallel, alignment of IQA measures with expert judgment depends heavily on the choice of measure, and commonly used IQA metrics such as SSIM and PSNR often fail to align with expert assessments of diagnostic usability. Our results demonstrate that evaluation choices are crucial: they can determine which models and methods appear best and are therefore selected for further development or deployment. The selection of evaluation references should therefore be treated as a central component of clinical validity in CXR machine learning, and justified with respect to the pathology, imaging task, and intended downstream clinical use.
The evaluation of vision-language models (VLMs) for chest X-ray (CXR) analysis has largely been limited to disease-presence classification without visual grounding. Such evaluations fail to verify the expert-level lesion perception necessary to ensure the clinical reliability of VLMs. To address these limitations, we introduce CheXpercept, a sequential, multi-level perception benchmark that mirrors a radiologist's cognitive workflow across coarse-level detection, fine-level contour evaluation and revision, and semantic-level attribute extraction. To ensure high clinical fidelity at scale, we construct the dataset using a semi-automated generation pipeline paired with a review by six medical experts. CheXpercept contains 10,400 QA items derived from 2,100 CXRs, covering seven clinically critical pulmonary and cardiac lesions. To demonstrate the current landscape of VLM perception, we benchmark 14 general and medical VLMs on CheXpercept. The models achieve adequate performance only at the coarse level, with accuracy degrading precipitously on deeper visual tasks. Notably, medical VLMs show almost no perceptual advantage over their general-domain counterparts, highlighting a systemic flaw in current domain adaptation. The code and dataset will be publicly available.
Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image. That inference is unsafe: a model exploiting finding-name priors scores like one that reads the scan, and no standard benchmark separates them. We introduce a causal audit that intervenes on the image, occluding the relevant region, occluding an irrelevant one, and swapping in another patient's same-label scan, and combines three behavioral metrics to test whether a correct answer depends on the image. Across nine systems, a text-only model with no image access reaches within 5.7 accuracy points of the best multimodal one, and a 119-billion-parameter multimodal model is statistically indistinguishable from a 7-billion text-only baseline. The audit splits the cohort into three models that ignore the image, one that is unstable, and five that use it selectively, for a subset of findings; the categories hold across a second dataset, resolution, and prompt phrasing. Against board-certified radiologists, a text-only model is statistically indistinguishable from a radiologist's accuracy while grounding at zero, whereas the image-using models ground at radiologist-comparable rates. Reported confidence flags ungrounded answers only when a model uses the image. Grounding audits, not accuracy, should gate clinical deployment.
Mahshad Lotfinia, Sebastian Ziegelmayer, Lisa Adams +3