cs.CVOct 30, 2025

A-TPT: Angular Diversity Calibration Properties for Test-Time Prompt Tuning of Vision-Language Models

Authors: Shihab Aaqil Ahamed, Udaya S. K. P. Miriya Thanthrige, Ranga Rodrigo, Muhammad Haris Khan

Organizations: Dept. of Electronic and Telecommunication Engineering, University of Moratuwa, Sri Lanka · Mohamed bin Zayed University of Artificial Intelligence, Abu Dhabi, UAE

Abstract

Test-time prompt tuning (TPT) has emerged as a promising technique for adapting large vision-language models (VLMs) to unseen tasks without relying on labeled data. However, the lack of dispersion between textual features can hurt calibration performance, which raises concerns about VLMs' reliability, trustworthiness, and safety. Current TPT approaches primarily focus on improving prompt calibration by either maximizing average textual feature dispersion or enforcing orthogonality constraints to encourage angular separation. However, these methods may not always have optimal angular separation between class-wise textual features, which implies overlooking the critical role of angular diversity. To address this, we propose A-TPT, a novel TPT framework that introduces angular diversity to encourage uniformity in the distribution of normalized textual features induced by corresponding learnable prompts. This uniformity is achieved by maximizing the minimum pairwise angular distance between features on the unit hypersphere. We show that our approach consistently surpasses state-of-the-art TPT methods in reducing the aggregate average calibration error while maintaining comparable accuracy through extensive experiments with various backbones on different datasets. Notably, our approach exhibits superior zero-shot calibration performance on natural distribution shifts and generalizes well to medical datasets. We provide extensive analyses, including theoretical aspects, to establish the grounding of A-TPT. These results highlight the potency of promoting angular diversity to achieve well-dispersed textual features, significantly improving VLM calibration during test-time adaptation. Our code will be made publicly available.

Figures & tables

Appendix figures & tables13 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 30, 2026

Improving Calibration in Test-Time Prompt Tuning for Vision-Language Models via Data-Free Flatness-Aware Prompt Pretraining

Test-time prompt tuning (TPT) has emerged as a promising technique for enhancing the adaptability of vision-language models by optimizing textual prompts using unlabeled test data. However, prior studies have observed that TPT often produces poorly calibrated models, raising concerns about the reliability of their predictions. Recent works address this issue by incorporating additional regularization terms that constrain model outputs, which improve calibration but often degrade performance. In this work, we reveal that these regularization strategies implicitly encourage optimization toward flatter minima, and that the sharpness of the loss landscape around adapted prompts is a key factor governing calibration quality. Motivated by this observation, we introduce Flatness-aware Prompt Pretraining (FPP), a simple yet effective pretraining framework for TPT that initializes prompts within flatter regions of the loss landscape prior to adaptation. We show that simply replacing the initialization in existing TPT pipelines--without modifying any other components--is sufficient to improve both calibration and performance. Notably, FPP requires no labeled data and incurs no additional computational costs during test-time tuning, making it highly practical for real-world deployment. The code is available at: https://github.com/YonseiML/fpp.
Oct 29, 2026

M-PFT: Angular Margin for Calibrated Prompt-Tuning of Fine-Tuned Vision-Language Models

Prompt-tuning has emerged as a parameter-efficient technique for adapting large-scale vision-language models (VLMs) to downstream tasks while keeping the pre-trained weights frozen. However, prompt-tuned VLMs often suffer from a base-to-novel dual miscalibration problem, where models typically show underconfidence on base classes and overconfidence on novel classes. Current VLM calibration approaches address this dual miscalibration either separately or jointly, but lack a geometric understanding of the hyperspherical embedding space and thus fail to exploit angular discriminative properties to adjust distorted decision boundaries. To address this, we propose M-PFT, a novel angular-margin approach for prompt tuning that introduces two complementary objectives to promote class discriminability and semantic anchoring. This enlarges the angular margin by 1) minimizing the maximum cosine similarity between tunable class embeddings to reduce embedding collapse and 2) minimizing the angular distance between each tunable embedding and its corresponding zero-shot embedding to preserve semantic geometry. Extensive experiments across 9 prompt-tuning methods with various backbones on 15 diverse datasets show that our approach reduces the average calibration error on novel classes, while remaining competitive on base classes and maintaining comparable accuracy. Further analyses reveal that M-PFT effectively adjusts distorted decision boundaries induced by prompt tuning while preserving the pre-trained embedding space, improving calibration with negligible computational overhead.
Sep 15, 2026

Bridging the Confidence Gap: Temperature Scaling for Calibrating Test-Time Prompt Tuning

Test-time prompt tuning (TPT) enables adaptation on a single test instance, achieving improved accuracy but often sacrificing calibration performance. Most existing calibration methods introduce additional regularization terms to promote dispersion across text embeddings and reduce calibration error, yet these methods often suffer from a drop in accuracy. Motivated by the well-calibrated nature of zero-shot predictions, we propose CoTS, a simple yet effective post-hoc calibration method that preserves accuracy. Specifically, CoTS applies temperature scaling to minimize the confidence gap between adapted and zero-shot predictions. To fully exploit the potential of multiple augmentations during adaptation, we introduce a weak-strong ensemble strategy that further boosts accuracy. We then apply CoTS to this ensemble, termed E-CoTS, to maintain its well-calibrated property. Extensive experiments on diverse datasets and backbones show that our approaches effectively mitigate miscalibration without compromising primary accuracy. For instance, E-CoTS reduces the average expected calibration error of TPT from 11.90% to 5.38% on ImageNet variants, while even increasing accuracy from 60.74% to 62.95%. Moreover, when integrated with existing calibration methods, E-CoTS usually enhances both accuracy and calibration simultaneously.