SRUG: A Fusion-Driven Generator Network for Medical Image Translation
Authors: Xihe Qiu, Yang Dai, Xiaoyu Tan, Sijia Li, Fenghao Sun, Lu Gan, Liang Liu
Organizations: School of Electronic and Electrical Engineering, Shanghai University of Engineering Science, Shanghai, China · Department of Thoracic Surgery, Zhongshan Hospital of Fudan University, Shanghai 200032, China · Department of Medical Oncology, Cancer Center, and Fudan Zhangjiang Institute, Zhongshan Hospital of Fudan University, Shanghai 200032, China · Clinical Research Unit, Institute of Clinical Science, Zhongshan Hospital of Fudan University, Shanghai 200032, China
MRI sequence synthesis aims to recover missing image contrast while preserving patient-specific anatomy. The choice of generation mechanism affects both optimization and the way source information reaches the synthesized image. In this study, we propose SRUG, a supervised standalone fusion-driven generator that learns a deterministic source-to-target mapping for paired MRI synthesis. Its direct reconstruction formulation removes generator-discriminator competition and requires neither variational latent sampling nor iterative diffusion denoising. To support structural fidelity within this formulation, SRUG uses a residual encoder adapted for image reconstruction, with a full-resolution convolutional stem, pooling-separated feature stages, and channel recalibration embedded in the residual branches. A nested multi-scale decoder (NMD) repeatedly fuses the resulting spatial features and predicts the target sequence through a single output head. L1 loss and Multi-Scale Structural Loss (MSS loss) jointly supervise the prediction, connecting the direct generation objective to anatomical detail recovery. Experiments on BraTS 2023 show competitive reconstruction fidelity and structural consistency across three MRI translation tasks. Architecture ablations assess the effects of channel recalibration, NMD, and structural supervision within the same generator framework. Additional evaluation on IXI supports applicability to another dataset and modality pair, while zero-shot testing on BraTS 2019 provides preliminary evidence of cross-dataset transferability. These results support direct supervised generation as a practical approach to paired MRI sequence synthesis, with the adapted encoding and reconstruction pathway providing the basis for structural preservation. The SRUG implementation is publicly available at https://github.com/RisingRich/SRUG.
Figures & tables
Fig. 1 : Schematic motivation for SRUG. Panels (a)–(d) illustrate concerns associated with adversarial optimization, variational reconstruction, diffusion-based translation, and zero-shot transfer, respectively. Panel (e) presents direct source-to-target reconstruction using the CRRB-based encoder, NMD, and paired L1 and MSS loss supervision. The listed advantages express design aims; synthesis quality and transferability are evaluated in the experiments.
Fig. 2 : SRUG workflow: (a) 2.5D preprocessing; (b) the encoder built from channel-recalibrated residual blocks (CRRBs), reconstruction with the nested multi-scale decoder (NMD), and loss supervision; and (c) encoder stage details. MSS loss denotes Multi-Scale Structural Loss, computed from MS-SSIM.
Task
Model
PSNR ↑
SSIM ↑
LPIPS ↓
MS-SSIM ↑
MSE ↓
NMSE ↓
BraTS 2023 T1 → T2
CycleGAN
18.9567 ± 0.2842
0.6912 ± 0.0093
0.1467 ± 0.0058
0.6293 ± 0.0286
861.8345 ± 52.1906
0.4430 ± 0.0278
NICE-GAN
23.8071 ± 0.2556
0.8486 ± 0.0069
0.1146 ± 0.0017
0.8795 ± 0.0043
290.8364 ± 18.5864
0.1558 ± 0.0116
Pix2Pix
25.1078 ± 0.0320
0.8711 ± 0.0007
0.0885 ± 0.0006
0.9018 ± 0.0007
212.5699 ± 2.0190
0.1133 ± 0.0014
ResViT
24.8802 ± 0.1528
0.8660 ± 0.0017
0.1419 ± 0.0006
0.8992 ± 0.0027
218.8124 ± 7.9094
0.1157 ± 0.0037
BBDM
25.5541 ± 0.0594
0.8272 ± 0.0034
0.0702 ± 0.0002
0.9240 ± 0.0007
200.5621 ± 3.6000
0.1151 ± 0.0033
Our
27.3122 ± 0.0641
0.9161 ± 0.0006
0.0519 ± 0.0007
0.9436 ± 0.0004
136.5155 ± 2.1574
0.0737 ± 0.0013
Table 1: Quantitative results across MRI translation settings. MSE is measured on [0,255].
Fig. 3 : Normalized radar comparison across seven MRI translation settings and six metrics.
Dataset
Task
Train patients
Test patients
Split strategy
BraTS 2023
T1 → T2 T1 → FLAIR T2 → FLAIR
237
56
patient-wise
IXI
PD → T2
462
116
patient-wise
BraTS 2019
T1 → T2 T1 → FLAIR T2 → FLAIR
–
335
external testing
Table 2: Patient-level train/test splits for MRI translation experiments.
Fig. 4 : Metric distributions across MRI translation settings.
Table 3: Wilcoxon significance tests for BraTS 2023 translation tasks.
Fig. 6 : T1 → T2 ablation of channel recalibration, NMD, and MSS loss in SRUG: (a) normalized grouped bars; (b) normalized heatmap; (c) component-removal profiles. Configurations are defined in Table 4 .
Fig. 8 : ROI-level error heatmaps in selected anatomical regions; brighter regions indicate larger errors.
Generator Configuration
Image Quality Assessment
Encoder w/o SE
CRRB encoder
Plain decoder
NMD
PSNR ↑
SSIM ↑
LPIPS ↓
MS-SSIM ↑
MSE ↓
NMSE ↓
Replacement experiments: module substitution under the same generator pipeline.
✓
✓
26.9974
0.9050
0.0624
0.9402
142.7445
0.0769
✓
✓
27.1447
0.9020
0.0733
0.9411
136.3203
0.0736
✓
✓
27.1491
0.9131
0.0533
0.9410
140.7279
0.0766
✓
✓
27.3122
0.9161
0.0519
0.9436
136.5155
0.0737
Table 4: T1 → T2 ablation of channel recalibration, NMD, and MSS loss in SRUG. Upper block: encoder–decoder variants; lower block: component removal. MSE is measured on [0,255].
Fig. 9 : Effect of channel recalibration on encoder feature maps at levels x1,0 – x4,0 . Top: encoder variant without channel recalibration. Bottom: encoder built from CRRBs.
Fig. 10 : Effect of encoder channel recalibration on NMD feature maps at nodes x0,1 – x0,4 . Top: features from the encoder variant without channel recalibration. Bottom: features from the encoder built from CRRBs.
UFR SFA · University of Poitiers, CNRS, XLIM, France · I3M common laboratory CNRS-Siemens Healthinners, Poitiers University Hospital and University of Poitiers, France +4
Northeastern University, Shenyang, China · Key Laboratory of Intelligent Computing in Medical Image, Shenyang, China · Computer Science and Engineering, Northeastern University, Shenyang, China +5
State Key Laboratory of Virtual Reality Technology and Systems, Beihang University · Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences · Faculty of Computer Science and Control Engineering, Shenzhen University of Advanced Technology