cs.CVJan 30, 2026

MASC: Metal-Aware Sampling and Correction via Reinforcement Learning for Accelerated MRI

Authors: Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo, Marilyn Lionts, Yanfan Zhu, Yuechen Yang, 

Organizations: Vanderbilt University, Nashville, TN, USA 37215 · Vanderbilt University Medical Center, Nashville, TN, USA 37232 · Oak Ridge National Laboratory, Oak Ridge, TN, USA 37831

Abstract

Metal implants in MRI cause severe artifacts that degrade image quality and hinder clinical diagnosis. Traditional approaches address metal artifact reduction (MAR) and accelerated MRI acquisition as separate problems. We propose MASC, a unified reinforcement learning framework that jointly optimizes metal-aware k-space sampling and artifact correction for accelerated MRI. To enable supervised training, we construct a paired MRI dataset using physics-based simulation, generating k-space data and reconstructions for phantoms with and without metal implants. This paired dataset provides simulated 3D MRI scans with and without metal implants, where each metal-corrupted sample has an exactly matched clean reference, enabling direct supervision for both artifact reduction and acquisition policy learning. We formulate active MRI acquisition as a sequential decision-making problem, where an artifact-aware Proximal Policy Optimization (PPO) agent learns to select k-space phase-encoding lines under a limited acquisition budget. The agent operates on undersampled reconstructions processed through a U-Net-based MAR network, learning patterns that maximize reconstruction quality. We further propose an end-to-end training scheme where the acquisition policy learns to select k-space lines that best support artifact removal while the MAR network simultaneously adapts to the resulting undersampling patterns. Experiments demonstrate that MASC's learned policies outperform conventional sampling strategies, and end-to-end training improves performance compared to using a frozen pre-trained MAR network, validating the benefit of joint optimization. Cross-dataset experiments on FastMRI with physics-based artifact simulation further confirm generalization to realistic clinical MRI data. The code and models of MASC have been made publicly available: https://github.com/hrlblab/masc

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

    Sep 26, 2026Zhengyi Lu, Ming Lu, Chongyu Qu +11Magnetic Resonance ImagingAccelerated MRI Reconstruction

  2. MGMAR: Metal-Guided Metal Artifact Reduction for X-ray Computed Tomography

    Mar 13, 2026Hyoung Suk Park, Kiwan JeonComputed TomographyImage Enhancement

  3. Next-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction

    May 19, 2026Yilmaz Korkmaz, Vishal M. PatelVisual Autoregressive ModelsComputational Imaging