physics.med-phFeb 17, 2026

Imaging-Derived Coronary Fractional Flow Reserve: Advances in Physics-Based, Machine Learning, and Physics-Informed Methods

Authors: Tanxin Zhu, Emran Hossen, Chen Zhao, Jingfeng Jiang, Michele Esposito, Jiguang Sun, Weihua Zhou

Organizations: Department of Applied Computing, Michigan Technological University, Houghton, MI, USA · Department of Computer Science, Kennesaw State University, Marietta GA, USA · Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA · Department of Cardiology, Medical University of South Carolina, Charleston, SC, USA · 

Abstract

Purpose of Review Imaging derived fractional flow reserve (FFR) is rapidly evolving beyond conventional computational fluid dynamics (CFD) based pipelines toward machine learning (ML), deep learning (DL), and physics informed approaches that enable fast, wire free, and scalable functional assessment of coronary artery stenosis. This review synthesizes recent advances in computed tomography (CT)- and angiography-based FFR measurement, with particular emphasis on emerging physics-informed neural networks and neural operators (PINNs and PINOs), as well as key considerations for their clinical translation. Recent Findings ML/DL approaches have markedly improved automation and computational speed, enabling prediction of pressure and FFR from anatomical descriptors or angiographic contrast dynamics. However, their real-world performance and generalizability can remain variable and sensitive to domain shift, due to multi-center heterogeneity, interpretability challenges, and differences in acquisition protocols and image quality. Physics informed learning introduces conservation structure and boundary condition consistency into model training, improving generalizability and reducing dependence on dense supervision while maintaining rapid inference. Recent evaluation trends increasingly highlight deployment oriented metrics, including calibration, uncertainty quantification, and quality control gatekeeping, as essential for safe clinical use. Summary The field is converging toward imaging derived FFR methods that are faster, more automated, and more reliable. While ML/DL offers substantial efficiency gains, physics informed frameworks such as PINNs and PINOs may provide a more robust balance between speed and physical consistency. Prospective multi center validation and standardized evaluation will be critical to support broad and safe clinical adoption.

Explore similar work

Sep 16, 2026

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.
Aug 11, 2026

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.
Jul 30, 2026

Same Branches, Different Trees: A Bifurcation Connectedness Metric for Coronary Artery Segmentation and FFR-CT Decision Agreement

Fractional flow reserve derived from CT angiography (FFR-CT) simulates flow through a patient-specific vessel model, so its accuracy depends on the connectedness of the segmented tree, not only on volumetric overlap: a segmentation can reach high Dice yet sever a bifurcation, dropping the downstream subtree and reversing the treatment decision. Topology-aware losses such as clDice and Skeleton Recall act on the global centreline and can miss localised breaks. We study the Bifurcation Connectedness Score (BCS), which scores connectedness at each ground-truth bifurcation, and soft-BCS, its differentiable training surrogate. BCS captures a property of segmentation quality the standard metrics miss: it responds strongly to breaks in connectedness while staying largely unchanged under connectedness-preserving narrowing. Higher BCS accompanies closer agreement between the FFR-CT decisions a solver makes on predicted versus ground-truth geometry, most clearly in severe disease (OR 2.16, CI [1.23, 4.18]). Both decisions come from the same solver, so this reflects geometric, not clinical, fidelity. In training, soft-BCS and Skeleton Recall recover the same branches but build different trees. Recovering branches and keeping them connected are separable properties, so we recommend reporting a measure of each.