cs.CVFeb 17, 2026

Scaling Ultrasound Volumetric Reconstruction via Mobile Augmented Reality

Authors: Kian Wei Ng, Yujia Gao, Deborah Khoo, Ying Zhen Tan, Chengzheng Mao, Haojie Cheng, Andrew Makmur, Kee Yuan Ngiam, 

Organizations: National University Health System, Singapore · College of Design and Engineering, National University of Singapore, Singapore

Abstract

Accurate volumetric characterization of lesions is essential for oncologic diagnosis, risk stratification, and treatment planning. While imaging modalities such as Computed Tomography provide high-quality 3D data, 2D ultrasound (2D-US) remains the preferred first-line modality for breast and thyroid imaging due to cost, portability, and safety factors. However, volume estimates derived from 2D-US suffer from high inter-user variability even among experienced clinicians. Existing 3D ultrasound (3D-US) solutions use specialized probes or external tracking hardware, but such configurations increase costs and diminish portability, constraining widespread clinical use. To address these limitations, we present Mobile Augmented Reality Volumetric Ultrasound (MARVUS), a resource-efficient system designed to increase accessibility to accurate and reproducible volumetric assessment. MARVUS is interoperable with conventional ultrasound (US) systems, using a foundation model to enhance cross-specialty generalization while minimizing hardware requirements relative to current 3D-US solutions. In a user study involving experienced clinicians performing measurements on breast phantoms, MARVUS yielded a substantial improvement in volume estimation accuracy (mean difference: 0.469 cm3) with reduced inter-user variability (mean difference: 0.417 cm3). Additionally, we prove that augmented reality (AR) visualizations enhance objective performance metrics and clinician-reported usability. Collectively, our findings suggests that MARVUS can enhance US-based cancer screening, diagnostic workflows, and treatment planning in a scalable, cost-conscious, and resource-efficient manner. Usage video demonstration available (https://youtu.be/m4llYcZpqmM).

Figures & tables

Explore similar work

Mar 1, 2026

MLRecon: Robust Markerless Freehand 3D Ultrasound Reconstruction via Coarse-to-Fine Pose Estimation

Freehand 3D ultrasound (US) reconstruction promises volumetric imaging with the flexibility of standard 2D probes, yet existing tracking paradigms face a restrictive trilemma: marker-based systems demand prohibitive costs, inside-out methods require intrusive sensor attachment, and sensorless approaches suffer from severe cumulative drift. To overcome these limitations, we present MLRecon, a robust markerless 3D US reconstruction framework delivering drift-resilient 6D probe pose tracking using a single commodity RGB-D camera. Leveraging the generalization power of vision foundation models, our pipeline enables continuous markerless tracking of the probe, augmented by a vision-guided divergence detector that autonomously monitors tracking integrity and triggers failure recovery to ensure uninterrupted scanning. Crucially, we further propose a dual-stage pose refinement network that explicitly disentangles high-frequency jitter from low-frequency bias, effectively denoising the trajectory while maintaining the kinematic fidelity of operator maneuvers. Experiments demonstrate that MLRecon significantly outperforms competing sensorless and sensor-aided methods, achieving average position errors as low as 0.88 mm on complex trajectories and yielding high-quality 3D reconstructions with sub-millimeter mean surface accuracy. This establishes a new benchmark for low-cost, accessible volumetric US imaging in resource-limited clinical settings.
Aug 17, 2026

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.
Jul 2, 2026

Towards Real-World Ultrasound Understanding: Large Vision-Language Models from Multi-Image Examinations with Long-Form Reports

Large vision-language models (LVLMs) have achieved strong performance across many medical imaging tasks, yet their application to ultrasound remains limited due to its inherent complexity and variability. In this work, we revisit what is truly needed to enable real-world ultrasound understanding. Instead of introducing complex architectures or elaborate training strategies, we show that data scale and clinically faithful data alignment are the key factors. We construct a large-scale dataset of 1.5M real-world ultrasound examinations, containing 17.7M images, multi-organ coverage, and paired uncurated clinical reports. Crucially, we organize the data at the examination level, aligning multiple images with their corresponding reports to reflect real clinical workflows. We then fine-tune a standard LVLM using low-rank adaptation (LoRA) on this dataset without task-specific modifications. Surprisingly, this simple recipe already leads to strong performance across diverse ultrasound understanding tasks, outperforming prior methods designed with more complex pipelines. Beyond these results, we present model and data scaling analyses that provide insights into the role of scale in ultrasound LVLMs.