Continuous Telemonitoring of Heart Failure using Personalised Speech Dynamics
Authors: Yue Pan, Xingyao Wang, Hanyue Zhang, Liwei Liu, Changxin Li, Gang Yang, Rong Sheng, Yili Xia, Ming Chu
Organizations: School of Information Science and Technology, Southeast University, Nanjing, China · Department of Cardiology, Chongqing Hospital of Jiangsu Province Hospital, Chongqing, China · Department of Cardiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China · Department of Cardiology, The Affiliated Taizhou People’s Hospital of Nanjing Medical University, Taizhou School of Clinical Medicine, Nanjing Medical University, Taizhou, China · Advanced Computing and Storage Laboratory, 2012 Laboratories, Huawei Technologies Co. Ltd. · Division of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
Remote monitoring of heart failure (HF) via speech signals provides a non-invasive and cost-effective solution for long-term patient management. However, substantial inter-individual heterogeneity in vocal characteristics often limits the accuracy of traditional cross-sectional classification models. To address this, we propose a Longitudinal Intra-Patient Tracking (LIPT) scheme designed to capture the trajectory of relative symptomatic changes within individuals. Central to this framework is a Personalised Sequential Encoder (PSE), which transforms longitudinal speech recordings into context-aware latent representations. By incorporating historical data at each timestamp, the PSE facilitates a holistic assessment of the clinical trajectory rather than modelling discrete visits independently. Experimental results from a cohort of 225 patients demonstrate that the LIPT paradigm significantly outperforms the classic cross-sectional approaches, achieving a recognition accuracy of 99.7% for clinical status transitions. The model's high sensitivity was further corroborated by additional follow-up data, confirming its efficacy in predicting HF deterioration and its potential to secure patient safety in remote, home-based settings. Furthermore, this work addresses the gap in existing literature by providing a comprehensive analysis of different speech task designs and acoustic features. Taken together, the superior performance of the LIPT framework and PSE architecture validates their readiness for integration into long-term telemonitoring systems, offering a scalable solution for remote heart failure management.
Figures & tables
Figure 1: Conceptual framework of the Longitudinal Intra-Patient Tracking (LIPT) paradigm for personalised HF monitoring. Unlike standard cross-sectional classification, which suffers from low accuracy due to inter-subject heterogeneity, the LIPT pipeline directly models intra-individual temporal sequences. The workflow comprises three primary stages: (a) Feature Extraction, in which speech signals are characterised by spectral (time-frequency), rhythmic, and glottal quality attributes at both global and frame-wise levels; (b) HF-Voice Feature Screening, which employs statistical significance tests to identify features with pathophysiological associations to HF, while correlations between various feature categories and the disease state are evaluated; and (c) Longitudinal Intra-Patient Tracking (LIPT), where sequential voice samples from each individual are processed by a Personalised Sequential Encoder (PSE) to capture longitudinal dependencies. Finally, a longitudinal classifier generates individualised tracking results, which are validated against clinical gold standards to monitor disease trajectories over time.
Task
Abbr.
Chinese Pinyin
Data Quantity
(Phonetic symbols)
adm./dis.
f-up (stable)
f-up (re-ad.)
Vowel 1
a
-
218
70
17
Vowel 2
u
-
213
70
18
Vowel 3
i
-
220
72
18
Short Sent. 1
pg
shan dong de ping guo you da you tian
217
70
19
Short Sent. 2
mm
ni you yi ge mei li de mei mei
197
67
16
Table 1: Speech tasks and their respective data quantity. A total of 7 tasks were attempted, including 3 vowels, 3 short sentences, and 1 long sentence.
Global Features
Feature Quantity
Cross-Sectional
Longitudinal Modeling
xgboost
FNN
xgboost
FNN
all
6373
51.1
55.7
56.8
68.2
HF-voice A
1775
69.3
62.5
75.0
77.3
HF-voice B
981
65.9
69.3
70.5
81.8
RASTA
2700
48.9
54.5
61.4
65.9
MFCC
1400
58.0
52.3
61.4
68.2
Table 2: Performance benchmarking (Accuracy) for the cross-sectional and LIPT scheme under varying feature selection configurations
Figure 2: Performance of different speech tasks with the PSE model. The long sentence task ’count’ had the best macro-F1, followed by short sentences (’pg’, ’mm’, and ’mlh’) and vowels (’a’, ’i’, and ’u’). The long sentence task’s specificity was also the highest, albeit the sensitivity was slightly lower than that of the short sentences ’mm’ and ’mlh’. These two short sentences, focusing on voiced consonants, are also relatively balanced in sensitivity and specificity.
Method
Features
Acc.
Prec.
Sens.
Spec.
F1
XGBoost
HF-voice A
75.0
72.0
81.8
68.2
74.9
HF-voice B
70.5
71.4
68.2
72.7
70.4
FNN
HF-voice A
77.3
75.0
81.8
72.7
77.2
HF-voice B
81.8
85.0
77.3
86.4
81.8
PSE(ours)
HF-voice A
64.6
67.1
70.1
65.6
64.3
HF-voice B
65.2
61.9
57.1
64.8
64.2
Table 3: Results of XGBoost, FNN, and PSE under the LIPT scheme.
Features
Acc.
Prec.
Sens.
Spec.
F1
all
24.7
21.6
94.4
6.0
22.9
MFCC
25.9
16.4
61.1
16.4
25.9
RASTA
70.6
41.5
94.4
64.2
67.6
Rhythm
18.8
16.0
66.7
6.0
18.1
Quality
48.2
3.6
5.5
59.7
34.4
RASTA+HF-voice A
40.0
26.9
100
23.9
40.0
Table 4: Results of the follow-up test set distinguishing rehospitalised patients.
Figure 3: Confusion matrix and Receiver Operating Characteristic (ROC) curve of the PSE on the follow-up data set, with the best settings overall (RASTA features with HF-voice feature sets A and B (see Section 3.4.3 )), with PSE models reported in section 2.2.3 . The most outstanding category of error is the false positive, indicating high confusion regarding the stable (non-hospitalised) class, where similar data is lacking in training. The relatively high area under the ROC curve (AUROC) suggests these errors stem from output misalignment rather than a lack of discriminative power.
Figure 4: Flowchart of the data collection process.
Figure 5: Architecture of the Personalised Sequential Encoder (PSE) and Longitudinal Classifier for speech-based monitoring. The framework consists of three operational stages: (1) Pretraining: The encoder acquires preliminary knowledge of speech patterns by reconstructing frame-level feature maps via a decoder. (2) Longitudinal Classifier Training: Frame-level features ( X0…XT−1 ) are processed through a convolutional network and aggregated with the global features to form the temporally-interpolated latent representations ( Z0…ZT−1 ). The system performs reference/target allocation to compare any pair of time points ( Zt1,Zt2 ), using a linear layer to produce local comparison results ( y^∈[0,1] ) optimised against clinical true labels. (3) Evaluation: The model integrates medical records and time stamps to produce final personal tracking results.
Feature Group
Prefix in ComPare2016
Description
Number
Name
1
Spectral
audspec
Spectral features
2
RASTA
audspecRasta
Relative-Spectral filtered [ 12 ] spectral features
3
ZCR
pcm_zcr
Zero-crossing rate of time signal
4
RMS Energy
pcm_RMSenergy
Root-mean-square signal frame energy
5
FFT
pcm_fftMag
Fast Fourier transform
Table 5: Description of the global feature set.
Feature Group
Description
ID of features
No.
Name
(see Appendix B )
1
Rhythm (energy)
Rhythm features correlated with energy
6, 8, 36, 37, 42, 48, 50, 68, 70
2
Rhythm (zcr)
Rhythm features correlated with zcr
9, 38-41, 43-47, 49, 69
3
MFCC
Mel-Frequency cepstral coefficients 0-13
51-64
4
Quality
Jitter, Shimmer [ 11 ] , logHNR [ 4 ] , cpp [ 9 ]
2-5, 65-67
5
RASTA
Relative Spectral Transform (RASTA) [ 12 ]
7, 10-35
Table 6: Description of the frame-level feature set.
Figure 6: Feature selection quantity and percentage with respect to the original global feature set. The spectral features (G1) are the highest in percentage in both paired and independent t-test selections, which are followed by the global RASTA features (G2). The RASTA features by frequency bands (G6) contribute the most in terms of absolute quantity in both cases.
Appendix figures & tables2 assets
Supplementary material from the paper’s appendix.
Appendix
Feature ID
Feature Name
Source
0
F0final_sma
Compare_2016 (openSMILE)
1
voicingFinalUnclipped_sma
2
jitterLocal_sma
3
jitterDDP_sma
4
shimmerLocal_sma
5
logHNR_sma
Appendix
Table 7: List of frame-level features. Extracted with frame window of 200 ms and step length of 100 ms .
Figure 7: Frame-level features’ Pearson correlation matrix. Brighter colour indicate higher relevance between the two features. The numbers on each axis are the feature ID (see Appendix A ).
Objective: This study aimed to evaluate which voice features can predict health deterioration in patients with chronic HF. Background: Heart failure (HF) is a chronic condition with progressive deterioration and acute decompensations, often requiring hospitalization and imposing substantial healthcare and economic burdens. Current standard-of-care (SoC) home monitoring, such as weight tracking, lacks predictive accuracy and requires high patient engagement. Voice is a promising non-invasive biomarker, though prior studies have mainly focused on acute HF stages. Methods: In a 2-month longitudinal study, 32 patients with HF collected daily voice recordings and SoC measures of weight and blood pressure at home, with biweekly questionnaires for health status. Acoustic analysis generated detailed vowel and speech features. Time-series features were extracted from aggregated lookback windows (e.g., 7 days) to predict next-day health status. Explainable machine learning with nested cross-validation identified top vocal biomarkers, and a case study illustrated model application. Results: A total of 21,863 recordings were analyzed. Acoustic vowel features showed strong correlations with health status. Time-series voice features within the lookback window outperformed corresponding standard care measures, achieving peak sensitivity and specificity of 0.826 and 0.782 versus 0.783 and 0.567 for SoC metrics. Key prognostic voice features identifying deterioration included delayed energy shift, low energy variability, and higher shimmer variability in vowels, along with reduced speaking and articulation rate, lower phonation ratio, decreased voice quality, and increased formant variability in speech. Conclusion: Voice-based monitoring offers a non-invasive approach to detect early health changes in chronic HF, supporting proactive and personalized care.
Fan Wu, Matthias P. Nägele, Daryush D. Mehta +4
Centre for Digital Health Interventions, ETH Zurich, Zurich, Switzerland · Agentic System Lab, ETH Zurich, Zurich, Switzerland · Cardiology, University Heart Center Zurich, University Hospital Zurich, Zurich, Switzerland +5
Objective: Heart failure (HF) presents a healthcare challenge due to its high comorbidity burden, aging patient population and frequent hospitalizations. Remote monitoring offers a promising approach to managing HF patients by early detection of health deterioration. Developing autonomous systems to detect signs of worsening in telemonitoring data is of interest to reduce the workload of healthcare personnel. Methods: We propose the TRACER model, a Transformer with Contrastive Event Representation, designed to predict timelines leading to rare hospitalization events in low-resolution and irregularly sampled telemonitoring data. TRACER incorporates time-aware embeddings for each biomarker, contrastive pre-training to enhance anomaly detection via representation learning, and independent binary classifiers for detection. We used measurement data containing remotely recorded biomarker sequences from 276 HF patients segmented into overlapping windows based on temporal rules, and labeled the windows based on the occurrence of HF relevant hospitalizations at the latter edge of the window. Results: TRACER was able to correctly predict 66.7% timelines leading up to HF hospitalizations in the highly imbalanced real-world dataset with an overestimation of 7.9%. Reformulating the training of TRACER as an event detection problem improved the predictive performance compared with training directly on forecasting windows, enabling more effective use of the limited hospitalization events. Conclusion: TRACER demonstrated superior performance in detecting signs of worsening status in real-world telemonitoring data compared to the other tested models. Significance: TRACER shows promise in identifying signs of clinical deterioration that allow for alerts to be generated to provide counteractive treatment in patients with HF.
Erik Aerts, Yinan Yu, Annika Rosengren +5
Department of Computer Science and Engineering, Chalmers Universiy of Technology, Gothenburg, Sweden · Department of Computer Science and Engineering, University of Gothenburg, Gothenburg, Sweden · Center for Digital Health, Sahlgrenska University Hospital, Gothenburg, Sweden +3
Accurate short-term mortality prediction in heart failure (HF) remains challenging, particularly when relying on structured electronic health record (EHR) data alone. We evaluate transformer-based models on a French HF cohort, comparing text-only, structured-only, multimodal, and LLM-based approaches. Our results show that enriching clinical text with entity-level representations improves prediction over CLS embeddings alone, and that supervised multimodal fusion of text and structured variables achieves the best overall performance. In contrast, large language models perform inconsistently across modalities and decoding strategies, with text-only prompts outperforming structured or multimodal inputs. These findings highlight that entity-aware multimodal transformers offer the most reliable solution for short-term HF outcome prediction, while current LLM prompting remains limited for clinical decision support.
Oumaima El Khettari, Virgile Barthet, Guillaume Hocquet +3
Nantes Univ., École Centrale Nantes, CNRS, LS2N, UMR 6004, 44000 Nantes, France · Université Paris-Saclay, CNRS, LISN, Orsay, France · Hôpital Saint Joseph, DIMID, et Service de Cardiologie, Paris, France