Organizations: School of Mathematical Sciences, Ocean University of China, China · School of Haide, Ocean University of China, China · School of Intelligent Science and Technology, Nanjing University, China · School of Computer Science and Engineering, Central South University, China · The Second Xiangya Hospital of Central South University, China
Segmentation of the main coronary artery from X-ray coronary angiography (XCA) sequences is crucial for the diagnosis of coronary artery diseases. However, this task is challenging due to issues such as blurred boundaries, inconsistent radiation contrast, complex motion patterns, and a lack of annotated images for training. Although Semi-Supervised Learning (SSL) can alleviate the annotation burden, conventional methods struggle with complicated temporal dynamics and unreliable uncertainty quantification. To address these challenges, we propose SAM3-based Teacher-student framework with Motion-Aware consistency and Progressive Confidence Regularization (SMART), a semi-supervised vessel segmentation approach for X-ray angiography videos. First, our method utilizes SAM3's unique promptable concept segmentation design and innovates a SAM3-based teacher-student framework to maximize the performance potential of both the teacher and the student. Second, we enhance segmentation by integrating the vessel mask warping technique and motion consistency loss to model complex vessel dynamics. To address the issue of unreliable teacher predictions caused by blurred boundaries and minimal contrast, we further propose a progressive confidence-aware consistency regularization to mitigate the risk of unreliable outputs. Extensive experiments on three datasets of XCA sequences from different institutions demonstrate that SMART achieves state-of-the-art performance while requiring significantly fewer annotations, making it particularly valuable for real-world clinical applications where labeled data is scarce. Our code is available at: https://github.com/qimingfan10/SMART.
Figures & tables
Figure 1: The overview of our proposed method. SMART (SAM3-based Motion-Aware Confidence Regularization for Teacher-Student Architecture) model enhances the reliability of teacher model outputs through a confidence-aware consistency loss Lconf . It incorporates temporal understanding from video sequences via dual-stream temporal consistency losses Lopti and Lcoh , while effectively leveraging annotated data through the supervised loss Lsup .
Method
XCAV
CAVSA
#Lab
DSC ↑
NSD ↑
clDice ↑
Spe ↑
Sen ↑
#Lab
DSC ↑
NSD ↑
clDice ↑
Spe ↑
Sen ↑
UNet [ 23 ]
16/111
70.80
60.12
69.24
97.75
66.33
16/1061
64.19
54.25
70.27
99.08
53.36
MedSAM2 [ 18 ]
16/111
22.37
21.07
3.57
84.14
32.01
16/1061
33.13
22.05
33.03
86.30
44.31
SAM3 [ 1 ]
16/111
42.73
30.86
34.51
98.11
35.59
16/1061
30.82
25.25
30.14
92.99
30.18
Denver [ 29 ]
16/111
73.30
51.50
70.40
98.50
65.60
16/1061
76.53
68.39
79.17
98.90
75.28
KnowSAM [ 9 ]
16/111
72.76
77.67
77.08
98.07
66.77
16/1061
72.76
60.57
76.12
98.07
66.77
Table 1: Quantitative results on the XCAV and CAVSA datasets.
Figure 2: Visualization results on the vessel segmentation.
Settings
XCAV
CAVSA
TPT
CCR
DSTC
DSC ↑
NSD ↑
clDice ↑
Spe ↑
Sen ↑
DSC ↑
NSD ↑
clDice ↑
Spe ↑
Sen ↑
✓
✓
82.38
83.42
79.84
99.16
77.26
78.87
67.35
81.17
99.42
73.80
✓
✓
76.71
78.29
79.86
97.46
78.69
25.82
21.24
32.65
99.77
19.38
✓
✓
76.24
77.27
78.53
98.05
74.33
47.77
40.71
50.37
99.59
38.46
✓
✓
✓
84.39
89.13
83.01
86.25
81.83
91.00
91.71
97.73
91.70
96.30
Table 2: Ablation study on the key components.
Figure 3: Visual comparisons of ablation studies.
Noise
DSC(%) ↑
NSD(%) ↑
clDice(%) ↑
Spe(%) ↑
Sen(%) ↑
2
83.59
88.45
81.82
85.38
79.91
4
83.73
87.53
82.02
85.14
81.76
6
83.79
88.40
82.51
85.47
79.41
8
84.39
89.13
83.01
86.25
81.83
Table 3: Effects of different numbers of noise perturbations on the XCAV dataset.
School of Biomedical Engineering, Sun Yat-sen University, Shenzhen, 518107, China. · Department of Cardiovascular Surgery, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China · Department of Laboratory Medicine, West China Hospital of Sichuan University, Chengdu, 610041, China.