GroundedSurg: A Multi-Procedure Benchmark for Language-Conditioned Surgical Tool Segmentation
Organizations: King Abdullah University of Science and Technology (KAUST), Saudi Arabia · Gaash Research Lab, National Institute of Technology Srinagar, India · Thapar Institute of Engineering and Technology, India · The University of Queensland, Australia
Abstract
Clinically reliable perception of surgical scenes is essential for advancing intelligent, context-aware intraoperative assistance such as instrument handoff guidance, collision avoidance, and workflow-aware robotic support. Existing surgical tool benchmarks primarily evaluate category-level segmentation, requiring models to detect all instances of predefined instrument classes. However, real-world clinical decisions often require resolving references to a specific instrument instance based on its functional role, spatial relation, or anatomical interaction capabilities not captured by current evaluation paradigms. We introduce GroundedSurg, the first language-conditioned, instance-level surgical grounding benchmark. Each instance pairs a surgical image with a natural-language description targeting a single instrument, accompanied by structured spatial grounding annotations including bounding boxes and point-level anchors. The dataset spans ophthalmic, laparoscopic, robotic, and open procedures, encompassing diverse instrument types, imaging conditions, and operative complexities. By jointly evaluating linguistic reference resolution and pixel-level localization, GroundedSurg enables a systematic and realistic evaluation of vision-language models in clinically realistic multi-instrument scenes. Extensive experiments demonstrate substantial performance gaps across modern segmentation and VLMs, highlighting the urgent need for clinically grounded vision-language reasoning in surgical AI systems. Code and data are publicly available at https://github.com/gaash-lab/GroundedSurg
Figures & tables
| Dataset | Domain | Multi-Proc. | Language | Spatial | Disambig. | Prompt |
|---|---|---|---|---|---|---|
| CaDIS [ 8 ] | Cataract | ✗ | ✗ | ✗ | ✗ | ✗ |
| AutoLaparo [ 30 ] | Laparoscopic | ✗ | ✗ | ✗ | ✗ | ✗ |
| SISVE [ 32 ] | Gastrectomy | ✗ | ✗ | ✓ | ✓ | ✗ |
| EndoVis [ 26 ] | Robotic | ✗ | ✗ | ✗ | ✗ | ✗ |
| CholecSeg8k [ 10 ] | Cholecystectomy | ✗ | ✗ | ✗ | ✗ | ✗ |
| CholecInstanceSeg [ 1 ] | Cholecystectomy | ✗ | ✗ | ✗ | ✓ | ✗ |
| Model | Params | [email protected] | [email protected] | BBox IoU | [email protected] | [email protected] | Mask IoU | NDE | Dice |
|---|---|---|---|---|---|---|---|---|---|
| Open-Source Models | |||||||||
| Qwen2.5-VL-Instruct [ 27 ] | 7B | 0.52 | 0.33 | 0.24 | 0.26 | 0.22 | 0.20 | 1.45 | 0.20 |
| Qwen3-VL-Instruct [ 3 ] | 8B | 0.36 | 0.13 | 0.11 | 0.17 | 0.12 | 0.09 | 1.78 | 0.12 |
| Gemma 3 ] [ 7 ] (12B) | 12B | 0.28 | 0.09 | 0.08 | 0.13 | 0.09 | 0.07 | 1.45 | 0.09 |
| Gemma 3 [ 7 ] (27B) | 27B | 0.43 | 0.11 | 0.12 | 0.11 | 0.07 | 0.06 | 1.52 | 0.07 |
| LLaMA 3.2 Vision [ 9 ] | 11B | 0.02 | 0.00 | 0.00 | 0.01 | 0.00 | 0.00 | 2.90 | 0.00 |
| Model | Prompt1 | Prompt2 | ||||||
|---|---|---|---|---|---|---|---|---|
| [email protected] | [email protected] | BBox IoU | NDE | [email protected] | [email protected] | BBox IoU | NDE | |
| Qwen2.5-VL-7B [ 27 ] | 0.52 | 0.33 | 0.24 | 1.45 | 0.38 | 0.09 | 0.11 | 1.43 |
| Qwen3-VL-8B [ 3 ] | 0.36 | 0.13 | 0.11 | 1.78 | 0.11 | 0.02 | 0.09 | 2.94 |
| Gemma3-27B [ 7 ] | 0.43 | 0.11 | 0.12 | 1.52 | 0.42 | 0.08 | 0.10 | 1.51 |
| InternVL-8B [ 4 ] | 0.29 | 0.05 | 0.07 | 1.69 | 0.37 | 0.09 | 0.10 | 1.42 |
| MedGemma-4B-it [ 24 ] | 0.29 | 0.04 | 0.07 | 1.88 | 0.21 | 0.06 | 0.07 | 1.91 |
Medical Image Grounding
Medical image grounding links clinical phrases, questions, and diagnoses to the image regions or slices that support them.
See all 76 papers