ArthroCut: Autonomous Policy Learning for Robotic Bone Resection in Knee Arthroplasty
Organizations: School of Biomedical Engineering, Tsinghua University, Beijing 100084, China. · Longwood Valley MedTech, Beijing 100176, China. · School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Abstract
Despite rapid commercialization of surgical robots, their autonomy and real-time decision-making remain limited in practice. To address this gap, we propose ArthroCut, an autonomous policy learning framework that upgrades knee arthroplasty robots from assistive execution to context-aware action generation. ArthroCut fine-tunes a Qwen--VL backbone on a self-built, time-synchronized multimodal dataset from 21 complete cases (23,205 RGB--D pairs), integrating preoperative CT/MR, intraoperative NDI tracking of bones and end effector, RGB--D surgical video, robot state, and textual intent. The method operates on two complementary token families -- Preoperative Imaging Tokens (PIT) to encode patient-specific anatomy and planned resection planes, and Time-Aligned Surgical Tokens (TAST) to fuse real-time visual, geometric, and kinematic evidence -- and emits an interpretable action grammar under grammar/safety-constrained decoding. In bench-top experiments on a knee prosthesis across seven trials, ArthroCut achieves an average success rate of 86% over the six standard resections, significantly outperforming strong baselines trained under the same protocol. Ablations show that TAST is the principal driver of reliability while PIT provides essential anatomical grounding, and their combination yields the most stable multi-plane execution. These results indicate that aligning preoperative geometry with time-aligned intraoperative perception and translating that alignment into tokenized, constrained actions is an effective path toward robust, interpretable autonomy in orthopedic robotic surgery.
Figures & tables
| Method | Metrics | |||||
|---|---|---|---|---|---|---|
| Success Rate (SR) | ||||||
| anterior chamfer | distal femur | anterior condyle | posterior condyle | tibial | posterior chamfer | |
| OpenVLA (ft) [ 17 ] | 0.29 (2/7) | 0.29 (2/7) | 0.29 (2/7) | 0.00 (0/7) | 0.29 (2/7) | 0.00 (0/7) |
| Diffusion Policy [ 34 ] | 0.47 (4/7) | 0.29 (2/7) | 0.47 (4/7) | 0.29 (2/7) | 0.00 (0/7) | 0.00 (0/7) |
| RT-2 (ft) [ 7 ] | 0.29 (2/7) | 0.29 (2/7) | 0.29 (2/7) | 0.00 (0/7) | 0.00 (0/7) | 0.00 (0/7) |
| Octo (ft) [ 35 ] | 0.29 (2/7) | 0.00 (0/7) | 0.00 (0/7) | 0.29 (2/7) | 0.00 (0/7) | 0.00 (0/7) |
| Method | Metrics | |||||
|---|---|---|---|---|---|---|
| Success weighted by Path Length (SPL) | ||||||
| anterior chamfer | distal femur | anterior condyle | posterior condyle | tibial | posterior chamfer | |
| OpenVLA (ft) [ 17 ] | 0.22 0.02 | 0.24 0.02 | 0.24 0.02 | 0.00 0.00 | 0.20 0.04 | 0.00 0.00 |
| Diffusion Policy [ 34 ] | 0.42 0.05 | 0.23 0.03 | 0.43 0.04 | 0.22 0.03 | 0.00 0.00 | 0.00 0.00 |
| RT-2 (ft) [ 7 ] | 0.21 0.02 | 0.18 0.03 | 0.20 0.03 | 0.00 0.00 | 0.00 0.00 | 0.00 0.00 |
| Octo (ft) [ 35 ] | 0.22 0.03 | 0.00 0.00 | 0.00 0.00 | 0.22 0.02 | 0.00 0.00 | 0.00 0.00 |
| Method | Inference time (ms) | Robot exec. time (s) |
|---|---|---|
| Vanilla Model | 267.14 | 121.89 |
| ArthroCut (Ours) | 302.52 | 107.33 |
| Method | Ablation | SR | SPL | |
|---|---|---|---|---|
| PIT | TAST | |||
| Vanilla Model | 0.05 | 0.04 | ||
| Vanilla Model | ✓ | 0.12 | 0.10 | |
| Vanilla Model | ✓ | 0.68 | 0.61 | |
| ArthroCut (Ours) | ✓ | ✓ | 0.86 | 0.75 |
Surgical Robotics
Surgical robotics develops robotic tools and systems for minimally invasive, image-guided, and microsurgical procedures.
See all 187 papers