3D CBCT Artefact Removal Using Perpendicular Score-Based Diffusion Models
Organizations: Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland · Piracicaba Dental School, University of Campinas, Piracicaba, Brazil · State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China · Department of Oral Health & Medicine, University Center for Dental Medicine, University of Basel, Basel, Switzerland ·
Abstract
Cone-beam computed tomography (CBCT) is a widely used 3D imaging technique in dentistry, offering high-resolution images while minimising radiation exposure for patients. However, CBCT is highly susceptible to artefacts arising from high-density objects such as dental implants, which can compromise image quality and diagnostic accuracy. To reduce artefacts, implant inpainting in the sequence of projections plays a crucial role in many artefact reduction approaches. Recently, diffusion models have achieved state-of-the-art results in image generation and have widely been applied to image inpainting tasks. However, to our knowledge, existing diffusion-based methods for implant inpainting operate on independent 2D projections. This approach neglects the correlations among individual projections, resulting in inconsistencies in the reconstructed images. To address this, we propose a 3D dental implant inpainting approach based on perpendicular score-based diffusion models, each trained in two different planes and operating in the projection domain. The 3D distribution of the projection series is modelled by combining the two 2D score-based diffusion models in the sampling scheme. Our results demonstrate the method's effectiveness in producing high-quality, artefact-reduced 3D CBCT images, making it a promising solution for improving clinical imaging.
Figures & tables
| SSIM ( ) | PSNR ( ) | RMSE ( ) | ||
| Projections | TPDM | 0.9290 0.0085 | 35.8660 1.1841 | 0.0037 0.0010 |
| DPS | 0.9110 0.0152 | 33.0039 1.7146 | 0.0044 0.0010 | |
| LI | 0.8834 0.0168 | 30.3120 1.1217 | 0.0055 0.0017 | |
| Reconstruction | TPDM | 0.9850 0.0078 | 50.3875 3.8834 | 0.0008 0.0003 |
| DPS | 0.9848 0.0100 | 49.9010 4.0727 | 0.0008 0.0003 | |
| LI | 0.9810 0.0084 | 47.1244 3.3138 | 0.0010 0.0004 |
Cone-Beam CT
Cone-beam computed tomography (CBCT) reconstructs three-dimensional anatomy from X-ray projections for dental, interventional, and radiotherapy imaging.
See all 47 papers