cs.LGMar 7, 2026

LightMedSeg: Lightweight 3D Medical Image Segmentation with Learned Spatial Anchors

Authors: Kavyansh Tyagi, Vishwas Rathi, Puneet Goyal

Organizations: National Institute of Technology Kurukshetra, India · Indian Institute of Technology Ropar, India

Abstract

Accurate and efficient 3D medical image segmentation is essential for clinical AI, where models must remain reliable under stringent memory, latency, and data availability constraints. Transformer-based methods achieve strong accuracy but suffer from excessive parameters, high FLOPs, and limited generalization. We propose LightMedSeg, a modular UNet-style segmentation architecture that integrates anatomical priors with adaptive context modeling. Anchor-conditioned FiLM modulation enables anatomy-aware feature calibration, while a local structural prior module and texture-aware routing dynamically allocate representational capacity to boundary-rich regions. Computational redundancy is minimized through ghost and depthwise convolutions, and multi-scale features are adaptively fused via a learned skip router with anchor-relative spatial position bias. Despite requiring only 0.48M parameters and 14.64~GFLOPs, LightMedSeg achieves segmentation accuracy within a few Dice points of heavy transformer baselines. Therefore, LightMedSeg is a deployable and data-efficient solution for 3D medical image segmentation. Code will be released publicly upon acceptance.

Figures & tables

Explore similar work

Feb 18, 2026

RefineFormer3D: Efficient 3D Medical Image Segmentation via Adaptive Multi-Scale Transformer with Cross Attention Fusion

Accurate and computationally efficient 3D medical image segmentation remains a critical challenge in clinical workflows. Transformer-based architectures often demonstrate superior global contextual modeling but at the expense of excessive parameter counts and memory demands, restricting their clinical deployment. We propose RefineFormer3D, a lightweight hierarchical transformer architecture that balances segmentation accuracy and computational efficiency for volumetric medical imaging. The architecture integrates three key components: (i) GhostConv3D-based patch embedding for efficient feature extraction with minimal redundancy, (ii) MixFFN3D module with low-rank projections and depthwise convolutions for parameter-efficient feature extraction, and (iii) a cross-attention fusion decoder enabling adaptive multi-scale skip connection integration. RefineFormer3D contains only 2.94M parameters, substantially fewer than contemporary transformer-based methods. Extensive experiments on ACDC and BraTS benchmarks demonstrate that RefineFormer3D achieves 93.44% and 85.9% average Dice scores respectively, outperforming or matching state-of-the-art methods while requiring significantly fewer parameters. Furthermore, the model achieves fast inference (8.35 ms per volume on GPU) with low memory requirements, supporting deployment in resource-constrained clinical environments. These results establish RefineFormer3D as an effective and scalable solution for practical 3D medical image segmentation.
Mar 24, 2026

Harnessing Lightweight Transformer with Contextual Synergic Enhancement for Efficient 3D Medical Image Segmentation

Transformers have shown remarkable performance in 3D medical image segmentation, but their high computational requirements and need for large amounts of labeled data limit their applicability. To address these challenges, we consider two crucial aspects: model efficiency and data efficiency. Specifically, we propose Light-UNETR, a lightweight transformer designed to achieve model efficiency. Light-UNETR features a Lightweight Dimension Reductive Attention (LIDR) module, which reduces spatial and channel dimensions while capturing both global and local features via multi-branch attention. Additionally, we introduce a Compact Gated Linear Unit (CGLU) to selectively control channel interaction with minimal parameters. Furthermore, we introduce a Contextual Synergic Enhancement (CSE) learning strategy, which aims to boost the data efficiency of Transformers. It first leverages the extrinsic contextual information to support the learning of unlabeled data with Attention-Guided Replacement, then applies Spatial Masking Consistency that utilizes intrinsic contextual information to enhance the spatial context reasoning for unlabeled data. Extensive experiments on various benchmarks demonstrate the superiority of our approach in both performance and efficiency. For example, with only 10% labeled data on the Left Atrial Segmentation dataset, our method surpasses BCP by 1.43% Jaccard while drastically reducing the FLOPs by 90.8% and parameters by 85.8%. Code is released at https://github.com/CUHK-AIM-Group/Light-UNETR.
Mar 23, 2026

SegMaFormer: A Hybrid State-Space and Transformer Model for Efficient Segmentation

The advent of Transformer and Mamba-based architectures has significantly advanced 3D medical image segmentation by enabling global contextual modeling, a capability traditionally limited in Convolutional Neural Networks (CNNs). However, state-of-the-art Transformer models often entail substantial computational complexity and parameter counts, which is particularly prohibitive for volumetric data and further exacerbated by the limited availability of annotated medical imaging datasets. To address these limitations, this work introduces SegMaFormer, a lightweight hybrid architecture that synergizes Mamba and Transformer modules within a hierarchical volumetric encoder for efficient long-range dependency modeling. The model strategically employs Mamba-based layers in early, high-resolution stages to reduce computational overhead while capturing essential spatial context, and reserves self-attention mechanisms for later, lower-resolution stages to refine feature representation. This design is augmented with generalized rotary position embeddings to enhance spatial awareness. Despite its compact structure, SegMaFormer achieves competitive performance on three public benchmarks (Synapse, BraTS, and ACDC), matching the Dice coefficient of significantly larger models. Empirically, our approach reduces parameters by up to 75x and substantially decreases FLOPs compared to current state-of-the-art models, establishing an efficient and high-performing solution for 3D medical image segmentation.