cs.CVMar 10, 2026

Physics-Driven 3D Gaussian Rendering for Zero-Shot MRI Super-Resolution

Authors: Shuting Liu, Lei Zhang, Wei Huang, Zhao Zhang, Zizhou Wang

Organizations: School of Artificial Intelligence, Sichuan University, Chengdu 610065, China · Institute of High Performance Computing, A*STAR, Singapore 138632

Abstract

High-resolution Magnetic Resonance Imaging (MRI) is vital for clinical diagnosis but limited by long acquisition times and motion artifacts. Super-resolution (SR) reconstructs low-resolution scans into high-resolution images, yet existing methods are mutually constrained: paired-data methods achieve efficiency only by relying on costly aligned datasets, while implicit neural representation approaches avoid such data needs at the expense of heavy computation. We propose a zero-shot MRI SR framework using explicit Gaussian representation to balance data requirements and efficiency. MRI-tailored Gaussian parameters embed tissue physical properties, reducing learnable parameters while preserving MR signal fidelity. A physics-grounded volume rendering strategy models MRI signal formation via normalized Gaussian aggregation. Additionally, a brick-based order-independent rasterization scheme enables highly parallel 3D computation, lowering training and inference costs. Experiments on two public MRI datasets show superior reconstruction quality and efficiency, demonstrating the method's potential for clinical MRI SR.

Figures & tables

Explore similar work

Jul 7, 2026

PhyMRI-SR: Toward Physics-Aware MRI Image Super-Resolution

Magnetic resonance imaging (MRI) super-resolution is vital for improving diagnostic accessibility, yet most methods treat it as a deterministic mapping from a fixed low-resolution input to a high-resolution target. This overlooks a key property of MRI acquisition physics: spatial resolution and signal-to-noise ratio (SNR) are inherently coupled, making any given low-resolution scan merely one of many possible realizations under varying acquisition trade-offs. We rethink MRI super-resolution as a physics-aware reconstruction problem, in which the goal is to identify the optimal resolution-SNR configuration and then super-resolve it to obtain high-quality MRI results. A key implication of this formulation is that MRI resolution becomes dynamic rather than fixed. To handle such resolution-heterogeneous inputs, we adapt 2D Gaussian Splatting (2D GS) to MRI by formulating reconstruction as a coordinate-based, resolution-agnostic rendering problem. To further enhance fidelity, we introduce three innovations: (1) a prior-aware Gaussian representation that combines an Anatomical Structure Prior for tissue-specific kernel initialization with an Imaging System Prior that captures hardware characteristics via a covariance dictionary; (2) a physics-constrained signal modeling scheme that predicts intrinsic tissue parameters (proton density rho and effective relaxation rate R2) and synthesizes intensities through governing physical equations, ensuring biophysically plausible contrast; and (3) a meta-learning framework that alleviates paired-data scarcity by pretraining on simulated data and adapting to real-world conditions. Extensive experiments on dynamic-resolution datasets and standard benchmarks demonstrate that our method achieves state-of-the-art performance, highlighting its strong potential for clinical deployment.
Sep 6, 2026

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr
Feb 24, 2026

M-Gaussian: An Magnetic Gaussian Framework for Efficient Multi-Stack MRI Reconstruction

Magnetic Resonance Imaging (MRI) is a crucial non-invasive imaging modality. In routine clinical practice, multi-stack thick-slice acquisitions are widely used to reduce scan time and motion sensitivity, particularly in challenging scenarios such as fetal brain imaging. However, the resulting severe through-plane anisotropy compromises volumetric analysis and downstream quantitative assessment, necessitating robust reconstruction of isotropic high-resolution volumes. Implicit neural representation methods, while achieving high quality, suffer from computational inefficiency due to complex network structures. We present M-Gaussian, adapting 3D Gaussian Splatting to MRI reconstruction. Our contributions include: (1) Magnetic Gaussian primitives with physics-consistent volumetric rendering, (2) neural residual field for high-frequency detail refinement, and (3) multi-resolution progressive training. Our method achieves an optimal balance between quality and speed. On the FeTA dataset, M-Gaussian achieves 40.31 dB PSNR while being 14 times faster, representing the first successful adaptation of 3D Gaussian Splatting to multi-stack MRI reconstruction.