cs.CVMar 10, 2026

FusionNet: a frame interpolation network for 4D heart models

Authors: Chujie Chang, Shoko Miyauchi, Ken'ichi Morooka, Ryo Kurazume, Oscar Martinez Mozos

Organizations: Kyushu University, Fukuoka 819-0395, Japan · Okayama University, Okayama 700-8530, Japan · Örebro University, Örebro 701-82, Sweden

Abstract

Cardiac magnetic resonance (CMR) imaging is widely used to visualise cardiac motion and diagnose heart disease. However, standard CMR imaging requires patients to lie still in a confined space inside a loud machine for 40-60 min, which increases patient discomfort. In addition, shorter scan times decrease either or both the temporal and spatial resolutions of cardiac motion, and thus, the diagnostic accuracy of the procedure. Of these, we focus on reduced temporal resolution and propose a neural network called FusionNet to obtain four-dimensional (4D) cardiac motion with high temporal resolution from CMR images captured in a short period of time. The model estimates intermediate 3D heart shapes based on adjacent shapes. The results of an experimental evaluation of the proposed FusionNet model showed that it achieved a performance of over 0.897 in terms of the Dice coefficient, confirming that it can recover shapes more precisely than existing methods. This code is available at: https://github.com/smiyauchi199/FusionNet.git

Figures & tables

Explore similar work

May 13, 2026

CineMesh4D: Personalized 4D Whole Heart Reconstruction from Sparse Cine MRI

Accurate 3D+t whole-heart mesh reconstruction from cine MRI is a clinically crucial yet technically challenging task. The difficulty of this task arises from two coupled factors: inherently sparse sampling of 3D cardiac anatomy by 2D image slices and the tight coupling between cardiac shape and motion. Current cardiac image-to-mesh approaches typically reconstruct only a subset of cardiac chambers or a single phase of the cardiac cycle. In this work, we propose CineMesh4D, a novel end-to-end 4D (3D+t) pipeline that directly reconstructs patient-specific whole-heart mesh from multi-view 2D cine MRI via cross-domain mapping. Specifically, we introduce a differentiable rendering loss that enables supervision of 3D+t whole-heart mesh from multi-view sparse contours of cine MRI. Furthermore, we develop a dual-context temporal block that fuses global and local cardiac temporal information to capture high-dimensional sequential patterns. In quantitative and qualitative evaluations, CineMesh4D outperforms existing approaches in terms of reconstruction quality and motion consistency, providing a practical pathway for personalized real-time cardiac assessment. The code will be publicly released once the manuscript is accepted.
Sep 15, 2025

End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRI

Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.
Aug 1, 2026

NISF++: Geometrically-grounded implicit representations of 3D+time cardiac function from 2D short- and long-axis MR views

Clinical acquisition in cardiac magnetic resonance (CMR) imaging involves obtaining cross-sectional planes of the heart along the radial and longitudinal directions. Despite these planes being 2D cross-sectional images of the heart, radiologists understand the 3D spatial and continuous temporal nature of the organ being imaged. The same can not be said about the conventional deep learning architectures used to process CMR images, which rely on in-plane and grid-based operations, and are hence unable to organically integrate information from all imaging planes. This paper builds upon previous work on neural implicit segmentation functions (NISF) to overcome unaddressed challenges in cardiac function modeling in the CMR domain. For a given subject, our architecture builds a shared 3D+time representations from all available acquisition planes regardless of orientation. By design, predictions along any imaging plane orientation are cross-sections of the same 3D representation, leading to spatio-temporal consistency across all slices. Moreover, our architecture makes the rotation and translation parameters of imaging planes learnable, allowing us to correct for the commonplace respiratory and patient motion between slice acquisitions under a rigid assumption. Furthermore, interpolation of intensities and segmentation can be performed in 4D at any desired resolution. We perform our study on a 120 subject sub-cohort of CMR imaging data from the UK-Biobank. Our in-plane segmentation performance is on-par with existing CMR segmentation methods and explore how the majority of failure cases arise from limitations in the ground-truth segmentation, for which our representations make predictions with better anatomical accuracy than its original training data. We also evaluate our motion-correction capabilities, displaying quantitative and qualitative improvements in slice alignment.