cs.CVMar 11, 2026

PET-F2I: A Comprehensive Benchmark and Parameter-Efficient Fine-Tuning of LLMs for PET/CT Report Impression Generation

Authors: Yuchen Liu, Wenbo Zhang, Liling Peng, Yichi Zhang, Yu Fu, Xin Guo, Chao Qu, Yuan Qi, 

Organizations: Fudan University · Shanghai Academy of Artificial Intelligence for Science · Shanghai Universal Medical Imaging Diagnostic Center · Lanzhou University

Abstract

PET/CT imaging is pivotal in oncology and nuclear medicine, yet summarizing complex findings into precise diagnostic impressions is labor-intensive. While LLMs have shown promise in medical text generation, their capability in the highly specialized domain of PET/CT remains underexplored. We introduce PET-F2I-41K (PET Findings-to-Impression Benchmark), a large-scale benchmark for PET/CT impression generation using LLMs, constructed from over 41k real-world reports. Using PET-F2I-41K, we conduct a comprehensive evaluation of 27 models across proprietary frontier LLMs, open-source generalist models, and medical-domain LLMs, and we develop a domain-adapted 7B model (PET-F2I-7B) fine-tuned from Qwen2.5-7B-Instruct via LoRA. Beyond standard NLG metrics (e.g., BLEU-4, ROUGE-L, BERTScore), we propose three clinically grounded metrics - Entity Coverage Rate (ECR), Uncovered Entity Rate (UER), and Factual Consistency Rate (FCR) - to assess diagnostic completeness and factual reliability. Experiments reveal that neither frontier nor medical-domain LLMs perform adequately in zero-shot settings. In contrast, PET-F2I-7B achieves substantial gains (e.g., 0.708 BLEU-4) and a 3.0x improvement in entity coverage over the strongest baseline, while offering advantages in cost, latency, and privacy. Beyond this modeling contribution, PET-F2I-41K establishes a standardized evaluation framework to accelerate the development of reliable and clinically deployable reporting systems for PET/CT.

Figures & tables

Explore similar work

Aug 30, 2026

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.
Apr 20, 2026

Region-Grounded Report Generation for 3D Medical Imaging: A Fine-Grained Dataset and Graph-Enhanced Framework

Automated medical report generation for 3D PET/CT imaging is fundamentally challenged by the high-dimensional nature of volumetric data and a critical scarcity of annotated datasets, particularly for low-resource languages. Current black-box methods map whole volumes to reports, ignoring the clinical workflow of analyzing localized Regions of Interest (RoIs) to derive diagnostic conclusions. In this paper, we bridge this gap by introducing VietPET-RoI, the first large-scale 3D PET/CT dataset with fine-grained RoI annotation for a low-resource language, comprising 600 PET/CT samples and 1,960 manually annotated RoIs, paired with corresponding clinical reports. Furthermore, to demonstrate the utility of this dataset, we propose HiRRA, a novel framework that mimics the professional radiologist diagnostic workflow by employing graph-based relational modules to capture dependencies between RoI attributes. This approach shifts from global pattern matching toward localized clinical findings. Additionally, we introduce new clinical evaluation metrics, namely RoI Coverage and RoI Quality Index, that measure both RoI localization accuracy and attribute description fidelity using LLM-based extraction. Extensive evaluation demonstrates that our framework achieves SOTA performance, surpassing existing models by 19.7% in BLEU and 4.7% in ROUGE-L, while achieving a remarkable 45.8% improvement in clinical metrics, indicating enhanced clinical reliability and reduced hallucination. Our code and dataset are available on GitHub.
Mar 18, 2026

DiffVP: Differential Visual Semantic Prompting for LLM-Based CT Report Generation

While large language models (LLMs) have advanced CT report generation, existing methods typically encode 3D volumes holistically, failing to distinguish informative cues from redundant anatomical background. Inspired by radiological cognitive subtraction, we propose Differential Visual Prompting (DiffVP), which conditions report generation on explicit, high-level semantic scan-to-reference differences rather than solely on absolute visual features. DiffVP employs a hierarchical difference extractor to capture complementary global and local semantic discrepancies into a shared latent space, along with a difference-to-prompt generator that transforms these signals into learnable visual prefix tokens for LLM conditioning. These difference prompts serve as structured conditioning signals that implicitly suppress invariant anatomy while amplifying diagnostically relevant visual evidence, thereby facilitating accurate report generation without explicit lesion localization. On two large-scale benchmarks, DiffVP consistently outperforms prior methods, improving the average BLEU-1-4 by +10.98 and +4.36, respectively, and further boosts clinical efficacy on RadGenome-ChestCT (F1 score 0.421). All codes will be released at https://github.com/ArielTYH/DiffVP/.