CT-Conditioned Diffusion Prior with Physics-Constrained Sampling for PET Super-Resolution
Organizations: Department of Bioengineering and Imperial-X, Imperial College London, London, U.K. · College of Artificial Intelligence, Nanjing University of Aeronautics and Astronautics, Nanjing, China. · School of Engineering, Zurich University of Applied Sciences, Winterthur, Switzerland. · Department of Nuclear Medicine, Inselspital, University of Bern, Bern, Switzerland. ·
Abstract
PET super-resolution is highly under-constrained because paired multi-resolution scans from the same subject are rarely available, and effective resolution is determined by scanner-specific physics (e.g., PSF, detector geometry, and acquisition settings). This limits supervised end-to-end training and makes purely image-domain generative restoration prone to hallucinated structures when anatomical and physical constraints are weak. We formulate PET super-resolution as posterior inference under heterogeneous system configurations and propose a CT-conditioned diffusion framework with physics-constrained sampling. During training, a conditional diffusion prior is learned from high-quality PET/CT pairs using cross-attention for anatomical guidance, without requiring paired LR--HR PET data. During inference, measurement consistency is enforced through a scanner-aware forward model with explicit PSF effects and gradient-based data-consistency refinement. Under both standard and OOD settings, the proposed method consistently improves experimental metrics and lesion-level clinical relevance indicators over strong baselines, while reducing hallucination artifacts and improving structural fidelity.
Figures & tables
| Setting | FWHM | Dose | Angular | Radial | Target Spacing | SR Factor |
|---|---|---|---|---|---|---|
| Standard | 8 mm | 10% | 2 | 2 | 8 mm | 4 |
| OOD | 12 mm | 5% | 3 | 2 | 12 mm | 6 |
| 8 mm (SR 4) | 12 mm (SR 6) | |||||
| Method | PSNR | SSIM | NMSE | PSNR | SSIM | NMSE |
| LR | 36.63 4.56 ∗ | 0.887 0.04 ∗ | 0.09 0.05 ∗ | 34.98 3.75 ∗ | 0.849 0.05 ∗ | 0.09 0.05 ∗ |
| DeepSR [ 5 ] | 42.49 3.70 ∗ | 0.957 0.02 ∗ | 0.03 0.03 ∗ | 37.27 3.31 ∗ | 0.896 0.04 ∗ | 0.06 0.05 ∗ |
| UNet [ 20 ] | 39.50 4.55 ∗ | 0.929 0.05 ∗ | 0.06 0.07 ∗ | 36.35 3.81 ∗ | 0.877 0.07 ∗ | 0.09 0.10 ∗ |
| SRCNN [ 21 ] | 42.75 3.70 ∗ | 0.960 0.02 ∗ | 0.03 0.03 ∗ | 37.33 3.32 ∗ | 0.899 0.04 ∗ | 0.06 0.05 ∗ |
| SRDPM [ 7 ] | 40.30 3.29 ∗ | 0.923 0.03 ∗ | 0.04 0.05 ∗ | 36.74 3.08 ∗ | 0.877 0.05 ∗ | 0.08 0.05 ∗ |
| Components | Metrics | ||||||
|---|---|---|---|---|---|---|---|
| Variant | CT cond. | DC | PSF | Sched. | PSNR | SSIM | NMSE |
| w/o DC | CrossAttn | 43.92 3.45 | 0.962 0.02 | 0.018 0.02 | |||
| w/o PSF | CrossAttn | ✓ | ✓ | 45.11 3.26 | 0.971 0.02 | 0.014 0.01 | |
| w/o PPCR | CrossAttn | ✓ | ✓ | 45.78 3.18 | 0.975 0.01 | 0.012 0.01 | |
| CT Concat | Concat | ✓ | ✓ | ✓ | 45.94 3.15 | 0.976 0.01 | 0.011 0.01 |
| Ours | CrossAttn | ✓ | ✓ | ✓ | 46.84 3.08 | 0.980 0.01 | 0.010 0.01 |
Medical Image Super-Resolution
Medical image super-resolution reconstructs fine spatial detail from low-resolution scans to support clearer anatomy and more useful clinical measurements.
See all 57 papers