Automated Diabetic Screening via Anterior Segment Ocular Imaging: A Deep Learning and Explainable AI Approach

Authors: Hasaan Maqsood, Saif Ur Rehman Khan, Sebastian Vollmer, Andreas Dengel, Muhammad Nabeel Asim

Organizations: BiogentX (biogentx.com, Renala Khurd, District Okara, Punjab, Pakistan. · Department of Computer Science, Rhineland-Palatinate Technical University of Kaiserslautern-Landau, Kaiserslautern, 67663, Germany. · German Research Center for Artificial Intelligence, Kaiserslautern, 67663, Germany. · Intelligentx GmbH (intelligentx.com), Kaiserslautern, Germany. · Department of Core Informatics, Graduate School of Informatics ,Osaka Metropolitan University, Saka, 599-8531, Japan.

Abstract

Diabetic retinopathy screening traditionally relies on fundus photography, requiring specialized equipment and expertise often unavailable in primary care and resource limited settings. We developed and validated a deep learning (DL) system for automated diabetic classification using anterior segment ocular imaging a readily accessible alternative utilizing standard photography equipment. The system leverages visible biomarkers in the iris, sclera, and conjunctiva that correlate with systemic diabetic status. We systematically evaluated five contemporary architectures (EfficientNet-V2-S with self-supervised learning (SSL), Vision Transformer, Swin Transformer, ConvNeXt-Base, and ResNet-50) on 2,640 clinically annotated anterior segment images spanning Normal, Controlled Diabetic, and Uncontrolled Diabetic categories. A tailored preprocessing pipeline combining specular reflection mitigation and contrast limited adaptive histogram equalization (CLAHE) was implemented to enhance subtle vascular and textural patterns critical for classification. SSL using SimCLR on domain specific ocular images substantially improved model performance.EfficientNet-V2-S with SSL achieved optimal performance with an F1-score of 98.21%, precision of 97.90%, and recall of 98.55% a substantial improvement over ImageNet only initialization (94.63% F1). Notably, the model attained near perfect precision (100%) for Normal classification, critical for minimizing unnecessary clinical referrals.

Figures & tables

Explore similar work

Feb 25, 2026

Mobile-Ready Automated Triage of Diabetic Retinopathy Using Digital Fundus Images

Diabetic Retinopathy (DR) is a major cause of vision impairment worldwide. However, manual diagnosis is often time-consuming and prone to errors, leading to delays in screening. This paper presents a lightweight automated deep learning framework for efficient assessment of DR severity from digital fundus images. We use a MobileNetV3 architecture with a Consistent Rank Logits (CORAL) head to model the ordered progression of disease while maintaining computational efficiency for resource-constrained environments. The model is trained and validated on a combined dataset of APTOS 2019 and IDRiD images using a preprocessing pipeline including circular cropping and illumination normalization. Extensive experiments including 3-fold cross-validation and ablation studies demonstrate strong performance. The model achieves a Quadratic Weighted Kappa (QWK) score of 0.9019 and an accuracy of 80.03 percent. Additionally, we address real-world deployment challenges through model calibration to reduce overconfidence and optimization for mobile devices. The proposed system provides a scalable and practical tool for early-stage diabetic retinopathy screening.
Aug 28, 2026

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

Diabetic retinopathy (DR) is a major cause of preventable blindness, creating a need for accurate and trustworthy automated screening. This study investigates an explainable DR classification framework using vision foundation models and multiple transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were evaluated using full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC of 0.758, while DINOv2 full fine-tuning and ViT full fine-tuning achieved the highest external AUROC of 0.920. Calibration was further assessed using reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM were evaluated against expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results demonstrate that foundation models, particularly DINOv2, can provide strong predictive performance, while LoRA offers a parameter-efficient alternative to full fine-tuning. Quantitative evaluation of explanation maps further supports the assessment of whether model attention corresponds to clinically relevant retinal lesions.
Jul 22, 2026

PRISM-DR: Per-lesion Retinal Inference with Specialist Models for Diabetic Retinopathy

Diabetic retinopathy is a leading cause of preventable blindness; its early lesions are small, low contrast, and easily missed in manual screening. Most automated detectors handle the four non-proliferative DR lesions: microaneurysms, hemorrhages, hard exudates, and soft exudates, with a single multi-class model, even though these lesions differ sharply in size, color, morphology, and prevalence, so a shared model favors common, easy classes over rare, difficult ones. We present PRISM-DR, a lesion-specific pipeline that trains one single-class detector per lesion, each with its own configuration. From a raw fundus image, the pipeline applies region of interest cropping, fundus-specific preprocessing, four parallel YOLO detectors, tiling, per-lesion ensembling of five cross-validation folds, and an inter-lesion suppression step that resolves overlaps by physical lesion size and clinical priority rather than confidence. Per lesion, the best of five YOLO generations is selected, and augmentation is tuned by Bayesian optimization. Trained on IDRiD with stratified five-fold cross-validation, the system reaches a test mAP50 of 0.527 and F1 of 0.529, highest AP50 on hard exudates with 0.561. Without fine-tuning, the models transfer well where the imaging scale is close to IDRiD and degrade as field of view and resolution depart. These modest absolute results reflect a small single-source training set and a difficult task; however, treating each lesion as a separate detection problem is a practical alternative to a single multi-class model.