cs.CVMar 17, 2026

SuCor: Susceptibility Distortion Correction via Parameter-Free and Self-Regularized Optimal Transport

Authors: Sreekar Chigurupati, Eleftherios Garyfallidis

Organizations: Intelligent Systems Engineering, Indiana University, Bloomington, Indiana, USA.

Abstract

We present SuCor, a method for correcting susceptibility induced geometric distortions in echo planar imaging (EPI) using optimal transport (OT) along the phase encoding direction. Given a pair of reversed phase encoding EPI volumes, we model each column of the distortion field as a Wasserstein-2 barycentric displacement between the opposing-polarity intensity profiles. Regularization is performed in the spectral domain using a bending-energy penalty whose strength is selected automatically via the Morozov discrepancy principle, requiring no manual tuning. On a human connectome project (HCP) dataset with left-right/right-left b0 EPI pairs and a co-registered T1 structural reference, SuCor achieves a mean volumetric mutual information of 0.341 with the T1 image, compared to 0.317 for FSL TOPUP, while running in approximately 12 seconds on a single CPU core.

Figures & tables

Explore similar work

Jun 19, 2026

Unsupervised Susceptibility Distortion Correction of EPI without Calibration Scans via Image Translation-Based Registration

Functional magnetic resonance imaging (fMRI) utilizes echo-planar imaging (EPI) to capture blood-oxygen-level-dependent (BOLD) signals with high temporal resolution. However, EPI is inherently sensitive to magnetic field inhomogeneities, resulting in susceptibility-induced geometric distortions along the phase-encoding (PE) direction. To correct these distortions, conventional approaches rely on additional calibration scans, such as field maps or reverse PE acquisitions, which are not always available in practice. To overcome this limitation, we propose SACRED, a calibration scan-free susceptibility distortion correction framework that corrects geometric distortions via image translation-based registration using only a routinely acquired anatomical T1-weighted (T1w) image and a unidirectional PE BOLD image. SACRED employs an invertible neural network as the image translation backbone to bridge the contrast gap between BOLD and T1w images while enforcing structural consistency through a modality independent neighborhood descriptor. This design enables the use of a mono-contrast similarity objective to train the registration network in an unsupervised manner without requiring distortion-corrected BOLD images. In addition, we incorporate test-time adaptation (TTA) to further enhance performance on out-of-distribution (OOD) data at inference time. SACRED was evaluated on one in-distribution (ID) dataset and two OOD datasets, and was compared with representative fMRI distortion correction methods. The results demonstrate that SACRED significantly outperforms competing methods on both ID and OOD datasets, exhibiting robustness to scanner and population shifts, partly enabled by TTA. The code will be made publicly available upon acceptance.
Jun 30, 2026

Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives

Echo Planar Imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field and distortion-free image directly from k-space data, without depending on an intermediate parallel-imaging reconstruction for the correction. The image and the B0 field are each represented as a superposition of Gaussian primitives embedded within an MRI physics forward model. The explicit, continuous parameterization captures both smooth regions and tissue boundaries and supports rotated-view EPI acquisitions without interpolation. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Rotated views distribute distortions across multiple phase-encoding orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value and high acceleration. Extensive visual comparisons further show improved detail fidelity and noise suppression.
Mar 27, 2026

FINDER: Zero-Shot Field-Integrated Network for Distortion-free EPI Reconstruction in Diffusion MRI

Echo-planar imaging (EPI) remains the cornerstone of diffusion MRI, but it is prone to severe geometric distortions due to its rapid sampling scheme that renders the sequence highly sensitive to B0B_{0} field inhomogeneities. While deep learning has helped improve MRI reconstruction, integrating robust geometric distortion correction into a self-supervised framework remains an unmet need. To address this, we present FINDER (Field-Integrated Network for Distortion-free EPI Reconstruction), a novel zero-shot, scan-specific framework that reformulates reconstruction as a joint optimization of the underlying image and the B0B_{0} field map. Specifically, we employ a physics-guided unrolled network that integrates dual-domain denoisers and virtual coil extensions to enforce robust data consistency. This is coupled with an Implicit Neural Representation (INR) conditioned on spatial coordinates and latent image features to model the off-resonance field as a continuous, differentiable function. Employing an alternating minimization strategy, FINDER synergistically updates the reconstruction network and the field map, effectively disentangling susceptibility-induced geometric distortions from anatomical structures. Experimental results demonstrate that FINDER achieves superior geometric fidelity and image quality compared to state-of-the-art baselines, offering a robust solution for high-quality diffusion imaging.