eess.IVMar 15, 2026

A Novel Framework using Intuitionistic Fuzzy Logic with U-Net and U-Net++ Architecture: A case Study of MRI Bain Image Segmentation

Authors: Hanuman Verma, Kiho Im, Akshansh Gupta, M. Tanveer

Organizations: Department of Mathematics, Bareilly College, Bareilly (MJP Rohilkhand University), Uttar Pradesh, 243005, India · Fetal Neonatal Neuroimaging and Developmental Science Center, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02115, USA · Division of Newborn Medicine, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02115, USA · Department of Pediatrics, Harvard Medical School, Boston, MA, USA · 

Abstract

Accurate segmentation of brain images from magnetic resonance imaging (MRI) scans plays a pivotal role in brain image analysis and the diagnosis of neurological disorders. Deep learning algorithms, particularly U-Net and U-Net++, are widely used for image segmentation. However, it finds difficult to deal with uncertainty in images. To address this challenge, this work integrates intuitionistic fuzzy logic into U-Net and U-Net++, propose a novel framework, named as IFS U-Net and IFS U-Net++. These models accept input data in an intuitionistic fuzzy representation to manage uncertainty arising from vague ness and imprecise data. This approach effectively handles tissue ambiguity caused by the partial volume effect and boundary uncertainties. To evaluate the effectiveness of IFS U-Net and IFS U-Net++, experiments are conducted on two publicly available MRI brain datasets: the Internet Brain Segmentation Repository (IBSR) and the Open Access Series of Imaging Studies (OASIS). Segmentation performance is quantitatively assessed using Accuracy, Dice Coefficient, and Intersection over Union (IoU). The results demonstrate that the proposed architectures consistently improve segmentation performance by effectively addressing uncertainty

Figures & tables

Explore similar work

Apr 13, 2026

An Uncertainty-Aware Loss Function Incorporating Fuzzy Logic: Application to MRI Brain Image Segmentation

Accurate brain image segmentation, particularly for distinguishing various tissues from magnetic resonance imaging (MRI) images, plays a pivotal role in finding the neurological dis ease and medical image computing. In deep learning approaches, loss functions are very crucial for optimizing the model. In this study, we introduce a novel loss function integrating fuzzy logic to deals uncertainty issues in brain image segmentation into various tissues. It integrates the well-known categorical cross-entropy (CCE) loss function and fuzzy entropy based on fuzzy logic. By employing fuzzy logic, this loss function accounts for the inherent uncertainties in pixel classifications. The proposed loss function has been evaluated on two publicly available benchmark datasets, IBSR and OASIS, using two widely recognised architectures, U-Net and U-Net++. Experimental results demonstrate that the trained model with proposed loss function provided better results in comparison to the CCE optimisation function in terms of various performance metrics. Additionally, it effectively enhances segmentation performance while handling meaningful uncer tainty during training. The findings suggest that this approach not only improves segmentation outcomes but also contributes to the reliability of model predictions.
Sep 24, 2026

Lightweight Vision Transformer-Based U-Net for Brain Tumor Segmentation from MRI

Accurate brain tumor segmentation from Magnetic Resonance Imaging is essential for diagnosis, treatment planning, and surgical guidance. Although Convolutional Neural Networks, particularly UNet, have achieved significant success in medical image segmentation, they often struggle to capture the long-range spatial dependencies required to model tumors with irregular shapes and complex boundaries. This paper proposes a lightweight Vision Transformer UNet that combines the hierarchical feature extraction capability of UNet with the global context modeling of Vision Transformers. The proposed architecture incorporates a compact ViT bottleneck within a U-Net encoder-decoder framework, enabling effective learning of both local and global features while maintaining computational efficiency with only 2.6 million trainable parameters. The model was evaluated on the TCGA LGG MRI Segmentation dataset, achieving a mean Intersection over Union of 0.8100 and a Dice score of 0.8446, outperforming the baseline UNet by 3.75% and 3.15%, respectively. Extensive quantitative and qualitative analyses, including confusion matrix evaluation, precision recall curves, per-image performance distribution, and tumor size dependency analysis, demonstrate the effectiveness and robustness of the proposed method for brain tumor segmentation.
Jul 22, 2026

Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation

Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may all alter model behavior without producing an obvious warning. We present a reproducible framework for evaluating uncertainty-aware segmentation under con- trolled clinical degradation. Our experiments use a synthetic multimodal brain tumor MRI cohort generated with a biophysical phantom simulator that follows the BraTS protocol. We train U-Net and Attention U-Net baselines for multi-class tumor sub-region segmentation and augment both models with Monte Carlo dropout to estimate per-voxel uncertainty. Across eight clinically motivated corruption types at five severity levels, we measure segmentation accuracy, calibration, failure detection, and selective prediction coverage. On clean data, Attention U-Net achieves a whole-tumor Dice of 0.990; under severe Gaussian noise, its performance falls to 0.089. Predictive uncertainty rises with degradation and tracks segmentation error (Pearson r = 0.53 under severity-3 Gaussian noise), allowing us to flag failures with an AUROC of 0.843. These results argue for uncertainty-aware inference as a practical safety layer in physician-in-the-loop radiology workflows. We release the code, trained models, and evaluation protocol to support direct reproduction.