cs.CVMar 22, 2026

CornOrb: A Multimodal Dataset of Orbscan Corneal Topography and Clinical Annotations for Keratoconus Detection

Authors: Mohammed El Amine Lazouni, Leila Ryma Lazouni, Zineb Aziza Elaouaber, Mohammed Ammar, Sofiane Zehar, Mohammed Youcef Bouayad Agha, Ahmed Lazouni, Amel Feroui, 

Organizations: Biomedical Engineering Laboratory, Abou Bakr Belkaid University, Tlemcen, Algeria · LIST Laboratory, M’Hamed Bougara Boumerdes University, Algeria · Lazouni Clinic, Tlemcen, Algeria · College of Excellence, University of Baghdad, Iraq · 

Abstract

In this paper, we present CornOrb, a publicly accessible multimodal dataset of Orbscan corneal topography images and clinical annotations collected from patients in Algeria. The dataset comprises 1,454 eyes from 744 patients, including 889 normal eyes and 565 keratoconus cases. For each eye, four corneal maps are provided (axial curvature, anterior elevation, posterior elevation, and pachymetry), together with structured tabular data including demographic information and key clinical parameters such as astigmatism, maximum keratometry (Kmax), central and thinnest pachymetry, and anterior/posterior asphericity. All data were retrospectively acquired, fully anonymized, and pre-processed into standardized PNG and CSV formats to ensure direct usability for artificial intelligence research. This dataset represents one of the first large-scale Orbscan-based resources from Africa, specifically built to enable robust AI-driven detection and analysis of keratoconus using multimodal data. The data are openly available at Zenodo.

Figures & tables

Explore similar work

Apr 14, 2026

Fundus Image-based Glaucoma Screening via Retinal Knowledge-Oriented Dynamic Multi-Level Feature Integration

While deep learning has advanced automated glaucoma screening via color fundus photography, existing purely data-driven models often overfit to confounding imaging artifacts and struggle to capture unpredictable pathological cues located beyond predefined anatomical boundaries. To address these limitations, we propose a retinal knowledge-oriented framework that synergizes dynamic multi-scale feature learning with domain-specific anatomical priors. The proposed architecture adopts a tri-branch structure to jointly model the global retinal context, the structural characteristics of the optic cup and disc, and dynamically cropped pathological regions. Specifically, we devise a Dynamic Window Mechanism (DWM) that adaptively discovers diagnostically informative patches via image-level supervision. Furthermore, we introduce a Knowledge-Enhanced Convolutional Block Attention Module (KE-CBAM) that explicitly incorporates retinal priors from a pre-trained foundation model RETFound to guide spatial attention, preventing the network from assigning spurious weights to irrelevant background noise. Extensive evaluations on the large-scale AIROGS dataset demonstrate that our method achieves a state-of-the-art AUC of 98.5%98.5\% and an accuracy of 94.6%94.6\%. More importantly, the integration of anatomical priors effectively mitigates the inherent class imbalance, significantly improving the detection of referable glaucoma cases. Additional validations on the SMDG-19 benchmark further confirm its superior cross-domain generalization, indicating that our contribution provides a robust, interpretable, and scalable solution for real-world clinical glaucoma diagnosis. Our code is available at https://github.com/magiczhuo/Glaucoma-Detection
Sep 24, 2026

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.
Sep 3, 2026

ARCOS: Zero-shot Boundary Localization for Corneal Layer Segmentation Across Optical Coherence Tomography Devices

Accurate segmentation of corneal layers in optical coherence tomography (OCT) is essential for quantitative assessment of corneal morphology, including layer thickness and structural changes associated with disease or surgery. However, automatic segmentation remains challenging because corneal interfaces are thin, affected by speckle noise, and variable across acquisition devices. In this work, we propose ARCOS, a patch-based zero-shot boundary localization framework for corneal layer segmentation in clinical anterior-segment OCT images. Rather than performing conventional region classification, the method predicts boundary heatmaps for the main corneal interfaces from overlapping native-resolution patches. Patch-level predictions are stitched across the full B-scan and converted into boundary locations to obtain continuous, anatomically ordered layer segmentations. The network combines multi-scale feature fusion with a self-conditioned refinement module that uses intermediate boundary information to improve local heatmap predictions while preserving spatial detail. The method was evaluated on clinical OCT images acquired from multiple devices and compared with representative segmentation baselines using boundary localization and derived thickness metrics. The proposed method achieved an off-by-one boundary localization accuracy of 95.1% and a mean absolute boundary error of 0.514 pixels on the matched-device test set. In zero-shot cross-device evaluation, it maintained an average off-by-one accuracy of 84.3% and a mean absolute boundary error of 0.855 pixels across unseen acquisition devices, outperforming the baseline models. Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the method's use for quantitative corneal OCT analysis.