cs.CVMar 23, 2026

PIVM: Diffusion-Based Prior-Integrated Variation Modeling for Anatomically Precise Abdominal CT Synthesis

Authors: Dinglun He, Baoming Zhang, Xu Wang, Yao Hao, Deshan Yang, Ye Duan

Organizations: Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, USA · Department of Computer Science, The University of Texas at Dallas, Richardson, TX, USA · Department of Radiation Oncology, Washington University in St. Louis, MO, USA · Department of Radiation Oncology, Duke University, Durham, NC, USA · 

Abstract

Abdominal CT data are limited by high annotation costs and privacy constraints, which hinder the development of robust segmentation and diagnostic models. We present a Prior-Integrated Variation Modeling (PIVM) framework, a diffusion-based method for anatomically accurate CT image synthesis. Instead of generating full images from noise, PIVM predicts voxel-wise intensity variations relative to organ-specific intensity priors derived from segmentation labels. These priors and labels jointly guide the diffusion process, ensuring spatial alignment and realistic organ boundaries. Unlike latent-space diffusion models, our approach operates directly in image space while preserving the full Hounsfield Unit (HU) range, capturing fine anatomical textures without smoothing. Source code is available at https://github.com/BZNR3/PIVM.

Figures & tables

Explore similar work

Apr 14, 2026

AbdomenGen: Sequential Volume-Conditioned Diffusion Framework for Abdominal Anatomy Generation

Computational phantoms are widely used in medical imaging research, yet current systems to generate controlled, clinically meaningful anatomical variations remain limited. We present AbdomenGen, a sequential volume-conditioned diffusion framework for controllable abdominal anatomy generation. We introduce the Volume Control Scalar (VCS), a standardized residual that decouples organ size from body habitus, enabling interpretable volume modulation. Organ masks are synthesized sequentially, conditioning on the body mask and previously generated structures to preserve global anatomical coherence while supporting independent, multi-organ control. Across 11 abdominal organs, the proposed framework achieves strong geometric fidelity (e.g., liver dice 0.83±0.050.83 \pm 0.05), stable single-organ calibration over [−3,+3][-3,+3] VCS, and disentangled multi-organ modulation. To showcase clinical utility with a hepatomegaly cohort selected from MERLIN, Wasserstein-based VCS selection reduces distributional distance of training data by 73.6% . These results demonstrate calibrated, distribution-aware anatomical generation suitable for controllable abdominal phantom construction and simulation studies.
May 18, 2026

Generation of Heterogeneous PET Images from Uniform Organ Activity Maps Using a Pretrained Domain-Adapted Diffusion Model

Synthetic PET images are valuable for quantitative imaging workflow development, scalable virtual imaging trials, and deep learning model training, but conventional physics-based simulation approaches are computationally intensive, limited in anatomical variability, and often fail to capture heterogeneous PET uptake. This study developed a pretrained domain-adapted diffusion (PAD) model for anatomy-conditioned PET synthesis from uniform organ activity maps. PAD adopts a natural-image pretrained text-to-image decoder with an upstream conditioning encoder and a downstream PET-domain adapter. A two-phase training strategy was used, with the first phase learning coarse uptake distributions and the second refining local image details. Uniform organ activity maps were generated from CT-based segmentations by assigning each organ its mean uptake from the paired PET image. Evaluation included quantitative accuracy, noise assessment, radiomic analysis, tumor segmentation performance, and a human observer study. PAD-generated images achieved high quantitative accuracy, with concordance correlation coefficients above 0.92 between organ mean SUVs and assigned activity values. The synthesized images showed noise levels and texture characteristics similar to target PET images and produced comparable tumor segmentation performance. In a two-alternative forced-choice observer study, four readers achieved approximately 50% accuracy, indicating visual indistinguishability between synthesized and target images. PAD also generated realistic PET images from XCAT-derived activity maps, demonstrating compatibility with phantom-based anatomical priors. Overall, PAD provides a diffusion-based framework for generating clinically relevant heterogeneous PET images from uniform organ activity maps derived from clinical segmentations or digital phantoms, supporting data augmentation and downstream imaging studies.
Aug 26, 2026

Unsupervised Anatomical Feature Learning via Diffusion Models: Enhanced Medical Image Segmentation with Denoising Diffusion Probabilistic Models

Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global anatomical structures, leading to boundary delineation failures in low-data regimes. This research paper proposes utilizing unsupervised Denoising Diffusion Probabilistic Models (DDPMs) to extract anatomical features. We train a DDPM on 21 unlabeled abdominal CT scans to learn structural representations, transferring the encoder weights to a downstream segmentation task evaluated on the BTCV multi-organ dataset. Diffusion pretraining significantly improved liver segmentation: Dice increased from 0.75±0.360.75\pm0.36 to 0.93±0.160.93\pm0.16 (p<5.33×10−26p < 5.33\times10^{-26}, 0.529 Cohen's d), Average Surface Distance (ASD) decreased by 66%, and 95th-percentile Hausdorff Distance (HD95) reduced by 45%. For kidney segmentation, Dice improved from 0.90±0.190.90\pm0.19 to 0.95±0.100.95\pm0.10 (p<4.01×10−11p < 4.01\times10^{-11}). Multi-organ pooled performance showed a 68% variance reduction and a 74% improvement in boundary precision (Dice 0.95±0.070.95\pm0.07). Crucially, frozen encoder models retained > 80% of fine-tuned performance without exposure to segmentation labels, proving the existence of learned anatomical priors. In low-data scenarios, diffusion-pretrained models maintained robust performance with only 50% (Dice: 0.92 liver, 0.94 kidney), 25%, and even 10% (Dice: 0.89 liver, 0.71 kidney) of labeled data. Using unlabeled images for diffusion-based pretraining successfully embeds robust anatomical features prior to human supervision, transforming U-Nets into anatomy-aware systems.