cs.CVMar 24, 2026

Curriculum-Driven 3D CT Report Generation via Language-Free Visual Grafting and Zone-Constrained Compression

Authors: V. K. Cody Bumgardner, Mitchell A. Klusty, Mahmut S. Gokmen, Evan W. Damron

Organizations: Center for Applied Artificial Intelligence, University of Kentucky, Lexington, KY 40506 USA

Abstract

Automated radiology report generation from 3D computed tomography (CT) volumes is challenging due to extreme sequence lengths, severe class imbalance, and the tendency of large language models (LLMs) to ignore visual tokens in favor of linguistic priors. We present Ker-VLJEPA-3B, a four-phase curriculum learning framework for free-text report generation from thoracic CT volumes. A phased training curriculum progressively adapts a Llama 3.2 3B decoder to ground its output in visual features from a frozen, self-supervised encoder. Our visual backbone (LeJEPA ViT-Large) is trained via self-supervised joint-embedding prediction on unlabeled CTs, without text supervision. Unlike contrastive models (CLIP, BiomedCLIP), this language-free backbone yields modality-pure representations. Vision-language alignment is deferred to the curriculum's bridge and generation phases. This modality-agnostic design can integrate any self-supervised encoder into an LLM without paired text during foundation training. Methodological innovations include: (1) zone-constrained cross-attention compressing slice embeddings into 32 spatially-grounded visual tokens; (2) PCA whitening of anisotropic LLM embeddings; (3) a positive-findings-only strategy eliminating posterior collapse; (4) warm bridge initialization transferring projection weights; and (5) selective cross-attention freezing with elastic weight consolidation to prevent catastrophic forgetting. Evaluated on the CT-RATE benchmark (2,984 validation volumes, 18 classes), Ker-VLJEPA-3B achieves a macro F1 of 0.429, surpassing the state-of-the-art (U-VLM, macro F1 = 0.414) by 3.6%, and reaching 0.448 (+8.2%) with threshold optimization. Ablation studies confirm 56.6% of generation quality derives from patient-specific visual content. Code and weights are available.

Figures & tables

Explore similar work

Mar 16, 2026

Beyond the Embedding Bottleneck: Adaptive Retrieval-Augmented 3D CT Report Generation

Automated radiology report generation from 3D CT volumes often suffers from incomplete pathology coverage. We provide empirical evidence that this limitation stems from a representational bottleneck: contrastive 3D CT embeddings encode discriminative pathology signals, yet exhibit severe dimensional concentration, with as few as 2 effective dimensions out of 512. Corroborating this, scaling the language model yields no measurable improvement, suggesting that the bottleneck lies in the visual representation rather than the generator. This bottleneck limits both generation and retrieval; naive static retrieval fails to improve clinical efficacy and can even degrade performance. We propose AdaRAG-CT, an adaptive augmentation framework that compensates for this visual bottleneck by introducing supplementary textual information through controlled retrieval and selectively integrating it during generation. On the CT-RATE benchmark, AdaRAG-CT achieves state-of-the-art clinical efficacy, improving Clinical F1 from 0.420 (CT-Agent) to 0.480 (+6 points); ablation studies confirm that both the retrieval and generation components contribute to the improvement. Code is available at https://github.com/renjie-liang/Adaptive-RAG-for-3DCT-Report-Generation.
Mar 18, 2026

DiffVP: Differential Visual Semantic Prompting for LLM-Based CT Report Generation

While large language models (LLMs) have advanced CT report generation, existing methods typically encode 3D volumes holistically, failing to distinguish informative cues from redundant anatomical background. Inspired by radiological cognitive subtraction, we propose Differential Visual Prompting (DiffVP), which conditions report generation on explicit, high-level semantic scan-to-reference differences rather than solely on absolute visual features. DiffVP employs a hierarchical difference extractor to capture complementary global and local semantic discrepancies into a shared latent space, along with a difference-to-prompt generator that transforms these signals into learnable visual prefix tokens for LLM conditioning. These difference prompts serve as structured conditioning signals that implicitly suppress invariant anatomy while amplifying diagnostically relevant visual evidence, thereby facilitating accurate report generation without explicit lesion localization. On two large-scale benchmarks, DiffVP consistently outperforms prior methods, improving the average BLEU-1-4 by +10.98 and +4.36, respectively, and further boosts clinical efficacy on RadGenome-ChestCT (F1 score 0.421). All codes will be released at https://github.com/ArielTYH/DiffVP/.
Aug 9, 2026

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.