cs.CVMar 28, 2026

MEDIC-AD: Towards Medical Vision-Language Model's Clinical Intelligence

Authors: Woohyeon Park, Jaeik Kim, Sunghwan Steve Cho, Pa Hong, Wookyoung Jeong, Yoojin Nam, Namjoon Kim, Ginny Y. Wong, 

Organizations: AIDAS Laboratory, Seoul National University · Samsung Changwon Hospital · Samsung Medical Center · NVIDIA, Santa Clara, USA

Abstract

Lesion detection, symptom tracking, and visual explainability are central to real-world medical image analysis, yet current medical Vision-Language Models (VLMs) still lack mechanisms that translate their broad knowledge into clinically actionable outputs. To bridge this gap, we present MEDIC-AD, a clinically oriented VLM that strengthens these three capabilities through a stage-wise framework. First, learnable anomaly-aware tokens (<Ano>) encourage the model to focus on abnormal regions and build more discriminative lesion centered representations. Second, inter image difference tokens (<Diff>) explicitly encode temporal changes between studies, allowing the model to distinguish worsening, improvement, and stability in disease burden. Finally, a dedicated explainability stage trains the model to generate heatmaps that highlight lesion-related regions, offering clear visual evidence that is consistent with the model's reasoning. Through our staged design, MEDIC-AD steadily boosts performance across anomaly detection, symptom tracking, and anomaly segmentation, achieving state-of-the-art results compared with both closed source and medical-specialized baselines. Evaluations on real longitudinal clinical data collected from real hospital workflows further show that MEDIC-AD delivers stable predictions and clinically faithful explanations in practical patient-monitoring and decision-support workflows

Figures & tables

Appendix figures & tables6 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 25, 2026

RVLM: Recursive Vision-Language Models with Adaptive Depth

Medical AI systems face two fundamental limitations. First, conventional vision-language models (VLMs) perform single-pass inference, yielding black-box predictions that cannot be audited or explained in clinical terms. Second, iterative reasoning systems that expose intermediate steps rely on fixed iteration budgets wasting compute on simple cases while providing insufficient depth for complex ones. We address both limitations with a unified framework. RVLM replaces single-pass inference with an iterative generate-execute loop: at each step, the model writes Python code, invokes vision sub-agents, manipulates images, and accumulates evidence. Every diagnostic claim is grounded in executable code, satisfying auditability requirements of clinical AI governance frameworks. RRouter makes iteration depth adaptive: a lightweight controller predicts the optimal budget from task-complexity features, then monitors progress and terminates early when reasoning stalls. We evaluate on BraTS 2023 Meningioma (brain MRI) and MIMIC-CXR (chest X-ray) using Gemini 2.5 Flash without fine-tuning. Across repeated runs, RVLM shows high consistency on salient findings (e.g., mass presence and enhancement) and can detect cross-modal discrepancies between Fluid-Attenuated Inversion Recovery (FLAIR) signal characteristics and segmentation boundaries. On MIMIC-CXR, it generates structured reports and correctly recognises view-specific artefacts. Code: https://github.com/nican2018/rvlm.
Mar 24, 2026

MedObvious: Exposing the Medical Moravec's Paradox in VLMs via Clinical Triage

Vision Language Models (VLMs) are increasingly used for tasks like medical report generation and visual question answering. However, fluent diagnostic text does not guarantee safe visual understanding. In clinical practice, interpretation begins with pre-diagnostic sanity checks: verifying that the input is valid to read (correct modality and anatomy, plausible viewpoint and orientation, and no obvious integrity violations). Existing benchmarks largely assume this step is solved, and therefore miss a critical failure mode: a model can produce plausible narratives even when the input is inconsistent or invalid. We introduce MedObvious, a 1,880-task benchmark that isolates input validation as a set-level consistency capability over small multi-panel image sets: the model must identify whether any panel violates expected coherence. MedObvious spans five progressive tiers, from basic orientation/modality mismatches to clinically motivated anatomy/viewpoint verification and triage-style cues, and includes five evaluation formats to test robustness across interfaces. Evaluating 17 different VLMs, we find that sanity checking remains unreliable: several models hallucinate anomalies on normal (negative-control) inputs, performance degrades when scaling to larger image sets, and measured accuracy varies substantially between multiple-choice and open-ended settings. These results show that pre-diagnostic verification remains unsolved for medical VLMs and should be treated as a distinct, safety-critical capability before deployment.
May 17, 2026

Medical Context Distorts Decisions in Clinical Vision Language Models

Vision-language models (VLMs) are increasingly proposed for clinical decision support, yet their reliability in real-world scenarios that require integrating both visual and textual context from medical records remains poorly characterized. This paper identifies three failure modes: (1) modality over-reliance on text over images, (2) spurious reliance on irrelevant clinical history, and (3) prompt sensitivity across semantically equivalent inputs. We evaluate a diverse set of general-domain and medically-tuned open and closed VLMs on chest x-ray tasks using MIMIC-CXR. By systematically manipulating image-text alignment, clinical history, and prompt formulations, we found that VLM decisions are dominated by the text modality, even when visual evidence is available. Moreover, we observed that VLMs are heavily influenced by irrelevant reports, while minor prompt changes can reverse correct image-based predictions. Our findings underscore the need for explicit safeguards and stress-testing before considering the use of these models in clinical practice.