Benchmark Problems and Benchmark Datasets for the evaluation of Machine and Deep Learning methods on Photoplethysmography signals: the D4 report from the QUMPHY project

Authors: Urs Hackstein, Jordi Alastruey, Philip Aston, Ciaran Bench, Peter H. Charlton, Loic Coquelin, Nando Hegemann, Vaidotas Marozas, 

Organizations: Technische Hochschule Mittelhessen - University of Applied Sciences, Giessen, Germany · King’s College London, London, United Kingdom · National Physical Laboratory, Teddington, United Kingdom · University of Cambridge, Cambridge, United Kingdom · 

Abstract

This report is part of the Qumphy project (22HLT01 Qumphy) that is funded by the European Union and is dedicated to the development of measures to quantify the uncertainties associated with Machine Learning algorithms applied to medical problems, in particular the analysis and processing of Photoplethysmography (PPG) signals. In this report, a list of six medical problems that are related to PPG signals and serve as Benchmark Problems is given. Suitable Benchmark datasets and their usage are described also.

Figures & tables

Explore similar work

Jul 22, 2026

Good Practice Guide for quantifying uncertainties for machine learning models applied to photoplethysmography signals

This Good Practice Guide presents work done in the QUMPHY project (Uncertainty quantification for machine learning models applied to photoplethysmography signals) that considered both machine learning and uncertainty quantification for problems which used photoplethysmography (PPG) signals from wearable devices as input. It provides high-level guidance on what types of machine learning model might be used and how different models compare when applied to both regression and classification tasks. It provides guidance on the implementation of different methods for uncertainty quantification, covering both model-dependent and model-independent techniques, and on the validation of the results provided by those methods. It also describes six benchmark problems together with pointers to different benchmark datasets for each problem. Software is described that can assist practitioners in implementing the methods described herein and there is a brief consideration of ethical issues. It concludes with a summary and recommendations.
Oct 9, 2026

PPG-Bench: A Unified Benchmark for PPG Foundation Models

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.
Mar 23, 2026

Deriving Health Metrics from the Photoplethysmogram: Benchmarks and Insights from MIMIC-III-Ext-PPG

Photoplethysmography (PPG) is one of the most widely captured biosignals for clinical prediction tasks, yet PPG-based algorithms are typically trained on small-scale datasets of uncertain quality, which hinders meaningful algorithm comparisons. We present a comprehensive benchmark for PPG-based clinical prediction using the \dbname~dataset, establishing baselines across the full spectrum of clinically relevant applications: multi-class heart rhythm classification, and regression of physiological parameters including respiratory rate (RR), heart rate (HR), and blood pressure (BP). Most notably, we provide the first comprehensive assessment of PPG for general arrhythmia detection beyond atrial fibrillation (AF) and atrial flutter (AFLT), with performance stratified by BP, HR, and demographic subgroups. Using established deep learning architectures, we achieved strong performance for AF detection (AUROC = 0.96) and accurate physiological parameter estimation (RR MAE: 2.97 bpm; HR MAE: 1.13 bpm; SBP/DBP MAE: 16.13/8.70 mmHg). Cross-dataset validation demonstrates excellent generalizability for AF detection (AUROC = 0.97), while clinical subgroup analysis reveals marked performance differences across subgroups by BP, HR, and demographic strata. These variations appear to reflect population-specific waveform differences rather than systematic bias in model behavior. This framework establishes the first integrated benchmark for multi-task PPG-based clinical prediction, demonstrating that PPG signals can effectively support multiple simultaneous monitoring tasks and providing essential baselines for future algorithm development.