cs.CVApr 2, 2026

Curia-2: Scaling Self-Supervised Learning for Radiology Foundation Models

Authors: Antoine Saporta, Baptiste Callard, Corentin Dancette, Julien Khlaut, Charles Corbière, Leo Butsanets, Amaury Prat, Pierre Manceron

Organizations: Raidium, 27 rue du Faubourg Saint-Jacques, 75014 Paris, France. · Department of Vascular and Oncological Interventional Radiology, Hôpital Européen Georges Pompidou, AP-HP, Paris, France · Faculté de Santé, Université Paris-Cité, Paris, France.

Abstract

The rapid growth of medical imaging has fueled the development of Foundation Models (FMs) to reduce the growing, unsustainable workload on radiologists. While recent FMs have shown the power of large-scale pre-training to CT and MRI analysis, there remains significant room to optimize how these models learn from complex radiological volumes. Building upon the Curia framework, this work introduces Curia-2, which significantly improves the original pre-training strategy and representation quality to better capture the specificities of radiological data. The proposed methodology enables scaling the architecture up to billion-parameter Vision Transformers, marking a first for multi-modal CT and MRI FMs. Furthermore, we formalize the evaluation of these models by extending and restructuring CuriaBench into two distinct tracks: a 2D track tailored for slice-based vision models and a 3D track for volumetric benchmarking. Our results demonstrate that Curia-2 outperforms all FMs on vision-focused tasks and fairs competitively to vision-language models on clinically complex tasks such as finding detection. Weights will be made publicly available to foster further research.

Figures & tables

Explore similar work

Jul 8, 2026

Vision Foundation Models in Radiology: A Scoping Review of Data, Methodology, Evaluation and Clinical Translation

Vision foundation models (VFMs) are increasingly being developed for radiological imaging, yet their definition, development and evaluation remain heterogeneous. We conducted a PRISMAScR scoping review of peer-reviewed studies published between January 2017 and March 2026 describing foundation models trained exclusively on radiological imaging data. Sixty-seven studies were included and mapped across three pillars: data scale and heterogeneity, architectural and pretraining scalability, and downstream transferability and generalization. Datasets primarily covered brain MRI, thoracoabdominal CT, and chest X-ray, ranging from fewer than 100,000 samples to multi-million-image cohorts. Transformer-based architectures and self-supervised pretraining predominated, particularly masked image modeling, contrastive learning and multi-stage approaches. Evaluation focused mainly on segmentation and classification, whereas cross-center, cross-scanner, anatomical and modality-shift validation was inconsistently reported. Alignment with FUTURE-AI principles was uneven. Overall, radiology-specific VFMs show promising transferability, but clinical translation remains constrained by limited data representativeness, heterogeneous benchmarks, incomplete reporting and insufficient deployment-oriented evaluation.
Mar 6, 2026

GreenRFM: Learning a resource-efficient radiology vision-language foundation model via supervision-centric pre-training

Radiology foundation models (RFMs) have largely inherited the scale-first recipe of natural-image vision--language pre-training. This recipe is difficult to deploy in 3D radiology, where training corpora are smaller, reports vary across institutions, and receiving hospitals often need local adaptation under privacy and compute constraints. We ask whether routine radiology reports can instead be converted into auditable diagnostic supervision that shapes the image encoder, text encoder, aligned space, and local-adaptation procedure. We develop GreenRFM, a supervision-centric pre-training framework organized around four empirical principles: More distilled, Ubiquitous, Semantic-enforcing, and Task-aligning (MUST) supervision. These principles convert noisy reports into structured diagnostic signals and use them to learn discriminative unimodal encoders plus an aligned image--text space for diagnosis-centered multimodal use. GreenRFM requires 24 GPU-hours on a single 24GB GPU (lightweight variant: 6GB VRAM, 4~hours) and reaches a zero-shot CT-RATE AUC of 84.8. Evaluations using more than 200,000 volumes from six institutions and two modalities show transfer to private clinical cohorts and to musculoskeletal MRI. On a local institutional cohort, computationally feasible retraining raises macro-AUC from 70.5 to 82.1. The aligned space also improves hepatocellular-carcinoma microvascular-invasion prediction and trans-arterial chemoembolization response analysis over established clinical scores. These results support supervision-centric pre-training as a practical route to resource-efficient, locally adaptable, diagnosis-centered radiology vision--language representations.
Sep 22, 2026

nnFoundation: 3D Foundation Models for Radiology

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.