cs.AIApr 3, 2026

VERT: Reliable LLM Judges for Radiology Report Evaluation

Authors: Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha

Organizations: Cornell University, Ithaca, NY, USA · Microsoft Healthcare & Life Sciences, Montréal, QC, Canada · Cornell University, Ithaca, NY · Microsoft Healthcare & Life Sciences, Redmond, WA, USA

Abstract

Current literature on radiology report evaluation has focused primarily on designing LLM-based metrics and fine-tuning small models for chest X-rays. However, it remains unclear whether these approaches are robust when applied to reports from other modalities and anatomies. Which model and prompt configurations are best suited to serve as LLM judges for radiology evaluation? We conduct a thorough correlation analysis between expert and LLM-based ratings. We compare three existing LLM-as-a-judge metrics (RadFact, GREEN, and FineRadScore) alongside VERT, our proposed LLM-based metric, using open- and closed-source models (reasoning and non-reasoning) of different sizes across two expert-annotated datasets, RadEval and RaTE-Eval, spanning multiple modalities and anatomies. We further evaluate few-shot approaches, ensembling, and parameter-efficient fine-tuning using RaTE-Eval. To better understand metric behavior, we perform a systematic error detection and categorization study to assess alignment of these metrics against expert judgments and identify areas of lower and higher agreement. Our results show that VERT improves correlation with radiologist judgments by up to 11.7% relative to GREEN. Furthermore, fine-tuning Qwen3 30B yield gains of up to 25% using only 1,300 training samples. The fine-tuned model also reduces inference time up to 37.2 times. These findings highlight the effectiveness of LLM-based judges and demonstrate that reliable evaluation can be achieved with lightweight adaptation.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 1, 2026

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.
Jun 17, 2026

Beyond Scalar Scores: Exploring LLM-based Metrics for Clinical Significance Evaluation in Radiology Reports

Reliable evaluation of generated radiology reports requires strict clinical accuracy, as omitted critical findings or mischaracterized radiographic observations can directly affect patient care. Existing metrics obscure this requirement by reducing report quality to a medically ungrounded scalar. Although Large Language Models (LLMs) possess rich medical knowledge, they likewise struggle to draw a reliable boundary between clinically significant errors and harmless variation. We study this boundary using ReEvalMed benchmark as testbed and evaluate metric-level clinical significance from detecting true clinical errors ("Discrimination") and tolerating insignificant variations ("Robustness"). Across 8 LLM evaluators under one-pass and two-pass settings, we identify a widespread discrimination bias: models effectively detect errors but also over-penalize harmless rephrasings. To mitigate this, we synthesize 4k report pairs and train lightweight interpretable metrics on Qwen3-8B and MedGemma-4B. Our trained metric sharpens the clinical significance boundary, surpassing 32B-scale medical LLMs and remaining competitive with proprietary models. Crucially, the more costly two-pass setting fails to consistently improve overall performance and mainly trades discrimination for robustness. These findings suggest one-pass trained metrics as the practical choice for cost-sensitive deployment, with two-pass inference reserved for settings where D-R balance is critical. We will release the dataset and metric.
Jun 13, 2026

ReportQA: QA-Based Radiology Report Evaluation

Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.