cs.LGApr 6, 2026

ECG Biometrics with ArcFace-Inception: External Validation on MIMIC and HEEDB

Authors: Arjuna Scagnetto

Abstract

ECG biometrics has been studied mainly on small cohorts and short inter-session intervals, leaving open how identification behaves under large galleries, external domain shift, and multi-year temporal gaps. We evaluated a 1D Inception-v1 model trained with ArcFace on an internal clinical corpus of 164,440 12-lead ECGs from 53,079 patients and tested it on larger cohorts derived from MIMIC-IV-ECG and HEEDB. The study used a unified closed-set leave-one-out protocol with Rank@K and TAR@FAR metrics, together with scale, temporal-stress, reranking, and confidence analyses. Under general comparability, the system achieved Rank@1 of 0.9506 on ASUGI-DB, 0.8291 on MIMIC-GC, and 0.6884 on HEEDB-GC. In the temporal stress test at constant gallery size, Rank@1 declined from 0.7853 to 0.6433 on MIMIC and from 0.6864 to 0.5560 on HEEDB from 1 to 5 years. Scale analysis on HEEDB showed monotonic degradation as gallery size increased and recovery as more examinations per patient became available. On HEEDB-RR, post-hoc reranking further improved retrieval, with AS-norm reaching Rank@1 = 0.8005 from a 0.7765 baseline. ECG identity information therefore remains measurable under externally validated large-scale closed-set conditions, but its operational quality is strongly affected by domain heterogeneity, longitudinal drift, gallery size, and second-stage score processing.

Figures & tables

Appendix figures & tables31 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 2, 2026

ECG-biometrics-bench: A Unified Framework for Reproducible Benchmarking of ECG Biometrics

Electrocardiogram (ECG) biometrics have emerged as a promising modality for continuous, liveness-aware authentication in wearable systems. However, many prior studies report overly optimistic results due to data leakage (e.g., random splits within the same session). To address this issue, we introduce ECG-biometrics-bench, a modular, reproducible benchmarking framework that standardizes preprocessing, segmentation, and evaluation across seven widely used public ECG datasets spanning clinical, ambulatory, and large-scale cohort settings. The framework supports both closed-set and open-set (i.e., subject-disjoint generalization in this work) evaluation, as well as progressively realistic protocols including cross-session and long-term temporal separation. To facilitate reproducible research in the community, the ECG-biometrics-bench repository will be made publicly accessible on GitHub upon the acceptance of this manuscript. Through a comprehensive multi-dataset analysis, we expose the Random Split Fallacy, demonstrating that intra-session evaluation protocols artificially inflate performance while masking severe degradation caused by temporal drift and unseen identities. Furthermore, by evaluating multiple architectures, including DeepECG, ResNet1D, and CNN-LSTM, we show that these failures are not model-specific but are likely inherent to current supervised feature-learning paradigms. Finally, we demonstrate that performance degradation due to temporal aging can be partially mitigated through a heavy enrollment, lightweight authentication strategy based on dynamic multi-session template fusion. These findings establish a more realistic baseline for ECG biometrics and highlight critical challenges that must be addressed for reliable real-world deployment.
Sep 18, 2026

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.
Sep 23, 2026

From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition

Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.