cs.CVApr 13, 2026

A Workflow to Efficiently Generate Dense Tissue Ground Truth Masks for Digital Breast Tomosynthesis

Authors: Tamerlan Mustafaev, Oleg Kruglov, Margarita Zuley, Luana de Mero Omena, Guilherme Muniz de Oliveira, Vitor de Sousa Franca, Bruno Barufaldi, Robert Nishikawa, 

Organizations: Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA · Center of Informatics, Federal University of Paraíba, Paraiba, BRA · Department of Radiology, University of Pennsylvania, Pennsylvania, USA · Department of Industrial Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA

Abstract

Digital breast tomosynthesis (DBT) is now the standard of care for breast cancer screening in the USA. Accurate segmentation of fibroglandular tissue in DBT images is essential for personalized risk estimation, but algorithm development is limited by scarce human-delineated training data. In this study we introduce a time- and labor-saving framework to generate a human-annotated binary segmentation mask for dense tissue in DBT. Our framework enables a user to outline a rough region of interest (ROI) enclosing dense tissue on the central reconstructed slice of a DBT volume and select a segmentation threshold to generate the dense tissue mask. The algorithm then projects the ROI to the remaining slices and iteratively adjusts slice-specific thresholds to maintain consistent dense tissue delineation across the DBT volume. By requiring annotation only on the central slice, the framework substantially reduces annotation time and labor. We used 44 DBT volumes from the DBTex dataset for evaluation. Inter-reader agreement was assessed by computing patient-wise Dice similarity coefficients between segmentation masks produced by two radiologists, yielding a median of 0.84. Accuracy of the proposed method was evaluated by having a radiologist manually segment the 20th and 80th percentile slices from each volume (CC and MLO views; 176 slices total) and calculate Dice scores between the manual and proposed segmentations, yielding a median of 0.83.

Explore similar work

Jul 14, 2026

Exact and Calibrated Diffusion Reconstruction for Digital Breast Tomosynthesis

Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, 25∘25^{\circ} protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge. Conditional diffusion priors achieve strong perceptual quality here but leave three clinical obstacles: inexact data consistency, unlocalized hallucination, and uncalibrated uncertainty. We enforce measurements exactly by replacing the per-step proximal update of a conditional diffusion sampler with exact Euclidean projection onto the data-consistent set, computed via an mm-dimensional dual system with a one-time Gram matrix AA⊤AA^{\top} factorization. This projection costs 4.5 ms per step (a 248×248\times speedup) and drives the data residual to the double-precision floor (2.4×10−132.4\times10^{-13}). We prove it is the ρ→0ρ\to0 limit of the proximal step, provide a no-harm theorem, and show that exactly consistent sample ensembles have variance supported on null(AA). Thus, the mean's entire error lies in the unmeasured subspace covered by the uncertainty map. On patient-derived breast phantoms, this improves fidelity at no depth-resolution cost. Conversely, a proximal step applied post-update degrades quality, isolating the consistency step's placement as decisive. Isotonic recalibration brings the ensemble spread to a calibrated error scale (expected calibration error 0.029→0.0080.029\to0.008; standardized error 4.7→0.964.7\to0.96), ranking errors better than the pure prior. We also repair a 20.3% adjoint mismatch in a deployed projector via a materialized operator of record. This is the first data-consistent, uncertainty-calibrated learned reconstruction for limited-angle DBT. The solver naturally relaxes to discrepancy-ball and maximum-a-posteriori modes for noisy measurements.
Oct 21, 2026

Reading the Mask: Descriptor-Grounded BI-RADS Rationale Generation for Breast MRI Segmentation

Deep learning based models accurately delineate tumours on dynamic contrast-enhanced MRI (DCE-MRI), but segmentation masks alone do not provide the rationales or reasoning used by radiologists to assess the lesion suspicion. This limits the explainability as well the clinical integration. We investigate whether clinically relevant descriptors can instead be derived from the segmentation masks and their dynamic contrast-enhancement series. We have used Breast Imaging Reporting and Data System (BI-RADS) guidelines as a structured framework. Using these guidelines we designed a BI-RADS decision tree with eight quantitative measurements using radiomics, together with the lesion size and component count, that determine the descriptors at eight nodes. Using these descriptors we generate natural-language rationale using a large language model. The model was constrained to express only the derived records from the decision tree. After applying this framework to the expert and automatic masks of each of the 1,506 cases in the MAMA-MIA dataset, we generated a reproducible corpus of 3,012 BI-RADS grounded rationales. We obtained a faithfulness score of 99.98% and a counterfactual accuracy of 99.3%, indicating that the generated rationales faithfully verbalises the measured descriptors and correctly reflects changes in the underlying record. Agreement between the descriptors from expert and automatic masks falls from 0.832 to 0.549 as mask quality falls from Good to Missed. The generated rationales are intended as draft representations for radiologist review and final sign-off rather than autonomous clinical reports.
Oct 16, 2026

NV-Generate-Body: 3D Latent Diffusion Model forControllable Anatomy, Tumor, and Demographic Body Mask Synthesis

Curating large labeled CT datasets is expensive and constrained by patient privacy. We present NV-Generate-BodyMask, a 3D latent diffusion model that synthesizes whole-body CT segmentation masks with precise, joint control over organ anatomy, tumor burden, and patient demographics. The model operates in the compressed latent space of a frozen mask autoencoder, generating 2563256^3 volumetric label maps conditioned on a 19-dimensional vector via Adaptive Group Normalization and cross-attention. A size-adaptive ROI loss with spatial halo weighting and a paired tumor injection pipeline enable accurate tumor size conditioning despite the scarcity of annotated tumor cases. Trained on 8,571 masks across 26 cohorts spanning 132 labels, the model achieves Spearman ρ=0.70ρ= 0.70--0.920.92 for organ size, 85--100% tumor recall for lung, pancreatic, colon, and bone lesions, and strong demographic alignment (BMI ρ=0.78ρ= 0.78, sex-conditioned perfect prostate control).