Exact and Calibrated Diffusion Reconstruction for Digital Breast Tomosynthesis

Authors: Imade Bouftini

Abstract

Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, 2525^{\circ} protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge. Conditional diffusion priors achieve strong perceptual quality here but leave three clinical obstacles: inexact data consistency, unlocalized hallucination, and uncalibrated uncertainty. We enforce measurements exactly by replacing the per-step proximal update of a conditional diffusion sampler with exact Euclidean projection onto the data-consistent set, computed via an mm-dimensional dual system with a one-time Gram matrix AAAA^{\top} factorization. This projection costs 4.5 ms per step (a 248×248\times speedup) and drives the data residual to the double-precision floor (2.4×10132.4\times10^{-13}). We prove it is the ρ0ρ\to0 limit of the proximal step, provide a no-harm theorem, and show that exactly consistent sample ensembles have variance supported on null(AA). Thus, the mean's entire error lies in the unmeasured subspace covered by the uncertainty map. On patient-derived breast phantoms, this improves fidelity at no depth-resolution cost. Conversely, a proximal step applied post-update degrades quality, isolating the consistency step's placement as decisive. Isotonic recalibration brings the ensemble spread to a calibrated error scale (expected calibration error 0.0290.0080.029\to0.008; standardized error 4.70.964.7\to0.96), ranking errors better than the pure prior. We also repair a 20.3% adjoint mismatch in a deployed projector via a materialized operator of record. This is the first data-consistent, uncertainty-calibrated learned reconstruction for limited-angle DBT. The solver naturally relaxes to discrepancy-ball and maximum-a-posteriori modes for noisy measurements.

Explore similar work

May 19, 2026cs.CV

EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis

Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows. The open source code for EPC-3D-Diff is available at https://github.com/ALZAHRAALTALIB/EPC-3D-Diff.
Alzahra Altalib, Chunhui Li, Haytham Ahmad Alewaidat +3
Apr 23, 2026eess.IV

Conditional Diffusion Posterior Alignment for Sparse-View CT Reconstruction

Computed Tomography (CT) is a widely used imaging modality in medical and industrial applications. To limit radiation exposure and measurement time, there is a growing interest in sparse-view CT, where the number of projection views is significantly reduced. Deep neural networks have shown great promise in improving reconstruction quality in sparse-view CT, especially generative diffusion models. However, these methods struggle to scale to large 3D volumes due to several reasons: (i) the high memory and computational requirements of 3D models, (ii) the lack of large 3D training datasets, and (iii) the inconsistencies across slices when using 2D models independently on each slice. We overcome these limitations and scale diffusion-based sparse-view CT reconstruction to large 3D volumes by combining conditional diffusion with explicit data consistency. We propose Conditional Diffusion Posterior Alignment (CDPA) to enable scalable 3D sparse-view CT reconstruction. A 2D U-Net diffusion model is conditioned on an initial 3D reconstruction to improve inter-slice consistency, combined with data-consistency alignment to match measured projections. Experiments on synthetic and real Cone Beam CT (CBCT) data show state-of-the-art performance, with ablations that confirm the synergistic effects of the proposed pipeline. Finally, we show that the same principles also strengthen fast denoising U-Nets, yielding near-diffusion quality at a fraction of the computational cost.
Luis Barba, Johannes Kirschner, Benjamin Bejar
Sep 9, 2026cs.CV

Advanced Brain Tissue Imaging with Data-Consistent Diffusion Priors in Laminographic X-Ray Nanoimaging

Nanoscale imaging of mammalian brains is critical for connectomics. X-ray laminography enables high-throughput imaging of extended, plate-like biological specimens. However, the tilted acquisition geometry leads to incomplete Fourier-space coverage, giving rise to a missing-cone of information. Conventional reconstruction methods cannot recover unmeasured information within the cone, resulting in artifacts that distort fine brain structures. While resolving these requires modeling 3D structure, direct 3D deep learning approaches are limited by data scarcity and computational cost. Here we introduce LUCID (Laminography with Unified Consistent Diffusion), a framework that combines multi-view diffusion priors with projection-domain data consistency. LUCID integrates complementary 3D structural information while enforcing strict alignment with the laminography forward model. On simulated datasets, LUCID substantially improves spatial fidelity and restores missing Fourier components, outperforming baseline methods. Applied to experimental laminography data, LUCID generalizes robustly despite being trained exclusively on fully sampled tomographic volumes, and effectively recovers unmeasured Fourier information.
Wenxuan Fang, Abraham L. Levitan, Ana Diaz +10