cs.CVApr 16, 2026

CXR-LT 2026 Challenge: Multi-Center Long-Tailed and Zero Shot Chest X-ray Classification

Authors: Hexin DongYi LinPengyu ZhouFengnian ZhaoAlan Clint LegastoJuno ChoDohui KimJustin Namuk Kim+20 more

Abstract

Chest X-ray (CXR) interpretation is hindered by the long-tailed distribution of pathologies and the open-world nature of clinical environments. Existing benchmarks often rely on closed-set classes from a single institution, failing to capture the prevalence of rare diseases or the appearance of novel findings. To address this, we present the CXR-LT challenge. The first event, CXR-LT 2023, established a large-scale benchmark for long-tailed multi-label CXR classification and identified key challenges in rare disease recognition. CXR-LT 2024 further expanded the label space and introduced a zero-shot task to study generalization to unseen findings. Building on the success of CXR-LT 2023 and 2024, this third iteration of the benchmark introduces a multi-center dataset comprising over 145,000 images from PadChest and NIH Chest X-ray datasets. Additionally, all development and test sets in CXR-LT 2026 are annotated by radiologists, providing a more reliable and clinically grounded evaluation than report-derived labels. The challenge defines two core tasks this year: (1) Robust Multi-Label Classification on 30 known classes and (2) Open-World Generalization to 6 unseen (out-of-distribution) rare disease classes. This paper summarizes the overview of the CXR-LT 2026 challenge. We describe the data collection and annotation procedures, analyze solution strategies adopted by participating teams, and evaluate head-versus-tail performance, calibration, and cross-center generalization gaps. Our results show that vision-language foundation models improve both in-distribution and zero-shot performance, but detecting rare findings under multi-center shift remains challenging. Our study provides a foundation for developing and evaluating AI systems in realistic long-tailed and open-world clinical conditions.

Explore similar work

Jul 1, 2026cs.CV

TRCGL-Net: A Long-Tailed Multi-Label Chest X-Ray Classification Framework with Generative Data Augmentation and Label Co-Occurrence Modeling

Chest X-ray multi-label classification is a core task in intelligent medical imaging diagnosis. However, real clinical data often exhibit extreme long-tailed distributions, leading to degraded performance on rare diseases in tail classes. This issue is not only driven by data scarcity but also by two intrinsic factors:1) attenuation of tail-class lesion representations under complex anatomical backgrounds, and 2) dominance of head classes in modeling label co-occurrence relationships. To address these challenges, we propose TRCGL-Net. First, a learnable text-guided conditional diffusion model is employed to generate high-quality tail-class chest X-ray image samples under disease semantic constraints, improving data diversity and realism of rare disease patterns while alleviating class imbalance and preserving pathology-consistent semantics.Second, a channel reweighting mechanism is introduced to perform feature recalibration by emphasizing disease-relevant feature channels, thereby improving feature discriminability under long-tailed distributions.A class-aware attention mechanism is further applied to generate class-specific attention maps, enabling the model to localize disease-relevant regions and focus on fine-grained lesion areas.Finally, a graph convolution network based on label co occurrence is introduced to establish an information propagation mechanism among categories. Experiments on the PadChest dataset show that the proposed method achieves a tail-class mAP of 0.4904, an overall mAP of 0.4408, and an mAUC of 0.8989, outperforming state-of-the-art methods. TRCGL-Net effectively improves recognition performance for rare diseases under long-tailed distributions and mitigates the impact of extreme class imbalance in chest X-ray multi-label classification.
Tong Shao, Hongshun Ling, Li Zhang +4
Jul 4, 2026cs.LG

Who Gets Missed in the Tail? Thresholded Subgroup Underdiagnosis in Long-Tailed Chest X-ray Classification

In chest X-ray (CXR) classification, acceptable ranking performance can still leave rare-positive patients below threshold, especially within subgroups. We study this pre-deployment fairness problem as an audit question: after a long-tailed multi-label CXR model is converted from scores into decisions, who is missed? Across VinDr-CXR and MIMIC-CXR/CXR-LT, we use a diagnostic ladder to separate class-level long-tail losses, subgroup-aware weighting, group robustness, and threshold selection. On VinDr-CXR, group-tail weighting followed by tail-aware thresholding reduces tail FNR from 0.665 to 0.269, sex worst-group FNR from 0.705 to 0.157, and age worst-group FNR from 0.822 to 0.133, while macro-mAP increases from 0.611 to 0.635. On MIMIC-CXR/CXR-LT, the same score-to-threshold comparison reduces tail FNR from 0.866 to 0.741 and lowers worst-group FNR across sex, age, race, and insurance; residual missed-positive rates nevertheless remain high. Paired bootstrap contrasts on VinDr support the thresholded FNR reductions, and GroupDRO reference runs indicate that aggregate group robustness alone does not remove rare subgroup misses in this setting. The study supports a narrow audit claim: rare-label fairness in CXR depends jointly on the finding, subgroup, and operating threshold, not on label frequency or ranking metrics alone.
Ha-Hieu Pham, Hai-Dang Nguyen, Dang P. M. Cao +5
Jun 19, 2026cs.CV

CheXpercept: A Benchmark for Evaluating Expert-Level Lesion Perception in Chest X-rays

The evaluation of vision-language models (VLMs) for chest X-ray (CXR) analysis has largely been limited to disease-presence classification without visual grounding. Such evaluations fail to verify the expert-level lesion perception necessary to ensure the clinical reliability of VLMs. To address these limitations, we introduce CheXpercept, a sequential, multi-level perception benchmark that mirrors a radiologist's cognitive workflow across coarse-level detection, fine-level contour evaluation and revision, and semantic-level attribute extraction. To ensure high clinical fidelity at scale, we construct the dataset using a semi-automated generation pipeline paired with a review by six medical experts. CheXpercept contains 10,400 QA items derived from 2,100 CXRs, covering seven clinically critical pulmonary and cardiac lesions. To demonstrate the current landscape of VLM perception, we benchmark 14 general and medical VLMs on CheXpercept. The models achieve adequate performance only at the coarse level, with accuracy degrading precipitously on deeper visual tasks. Notably, medical VLMs show almost no perceptual advantage over their general-domain counterparts, highlighting a systemic flaw in current domain adaptation. The code and dataset will be publicly available.
Geon Choi, Hangyul Yoon, Nalee Kim +5