cs.ROApr 28, 2026

SlicerRoboTMS: An Open-Source 3D Slicer Extension for Robot-Assisted Transcranial Magnetic Stimulation

Authors: Wenzhi BaiYituo GuoBhaskar BasuAndrew WeightmanZhenhong Li

Organizations: Department of Electrical and Electronic Engineering · University of Manchester · Manchester, U.K. · Rehabilitation Medicine · Manchester University NHS Foundation Trust · Department of Mechanical and Aerospace Engineering

Abstract

Robot-assisted Transcranial Magnetic Stimulation (Robo-TMS) is an image-guided robotic intervention that enhances the accuracy and reproducibility of conventional Transcranial Magnetic Stimulation (TMS), a widely used non-invasive brain stimulation procedure in clinical treatment and neuroscience research. Despite its potential, the development of Robo-TMS remains challenging due to the need for multidisciplinary expertise spanning medical imaging, computer vision, and robotics. This paper presents SlicerRoboTMS, an open-source 3D Slicer extension that provides a unified interaction infrastructure for Robo-TMS research. By leveraging 3D Slicer's medical image computing and visualisation capabilities, the extension supports Magnetic Resonance Imaging (MRI)-based neuronavigation and interfaces with robotic systems through standardised communication protocols and configurable system descriptions. An example integration is presented to demonstrate how SlicerRoboTMS can be incorporated into a representative Robo-TMS workflow. Designed to support diverse hardware configurations and rapid prototyping, SlicerRoboTMS lowers the barrier to entry and facilitates reproducible and extensible research in Robo-TMS. The extension is available at https://github.com/OpenRoboTMS/SlicerRoboTMS.

Explore similar work

May 29, 2026cs.RO

Shaft-integrated Force Sensing with Transformer-based Dynamics Compensation for Telesurgery

Robot-Assisted Minimally Invasive Surgery (RAMIS) enhances surgeon dexterity, with newer platforms leveraging haptic feedback to further improve performance. Such force information has broader potential to inform performance assessment, tactile localization, and surgical autonomy. This motivates the need for accessible approaches to integrating force sensing into RAMIS tools. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes reproducibility and accessibility for research applications, requiring no specialized manufacturing tools. A transformer neural network integrates force sensor measurements with robot state information to aid estimation of applied forces at the end-effector, compensating for internal cable forces arising from actuation. Our proposed approach achieved normalized errors below 6%, and generalized to unseen conditions better than purely proximal data-driven sensing approaches. High internal cable forces caused sensor saturation and reduced axial force observability, which can degrade performance along the tool's major axis and under higher load conditions. Given current levels of performance, the balance of system integrability and performance enables applications and research into timely topics of haptic feedback, skill assessment, and force-informed autonomy in RAMIS. Videos and code are available at https://enhanced-telerobotics.github.io/shaft_force_sensing/.
Shuyuan Yang, Grant Boone, Timo Markert +4
May 15, 2026cs.CV

MHMamba: Multi-Head Mamba for 3D Brain Tumor Segmentation

Brain tumors exhibit high heterogeneity in morphology and multimodal contrast, making manual slice-by-slice de lineation time-consuming and experience-dependent, thus necessitating efficient and stable automated segmentation methods. To address the limitations of CNNs in modeling long-range dependencies, and the heavy computational and memory overhead and inter-block contextual in coherence of Transformers in 3D MRI, this paper proposes Multi-Head Mamba (MHMamba). This method combines a U-shaped architecture with a multi-head state-space model (Mamba), splitting the channel dimension into parallel SSM heads and aggregating them with residuals. This enhances long-range representation and improves the stability of multimodal training while maintaining linear complexity. To further align statistics and enhance lesion response, we designed a channel-space calibration module for multi-head outputs and introduced an adaptive fusion mechanism at skip connections to dynamically connect global semantics with local details, thereby improving boundary consistency and the detection of small-volume lesions. We conducted experiments and ablations on BraTS2021 and BraTS2023. The results showed that MHMamba achieved stable and significant improvements in overall accuracy, boundary smoothness, and sensitivity to tumor core and small-volume enhancement areas, while preserving the linear-complexity advantage of Mamba-based modeling, thus verifying the effectiveness and versatility of the method.
Hanjun Tao, Hua Wang, Fan Zhang
Jun 22, 2026cs.RO

A Unified Benchmark for RCM-Constrained Visual Servoing: Modeling-Controller Interaction and Robustness Analysis in Laparoscopic Robots

In robot-assisted laparoscopic minimally invasive surgery (MIS), accurate enforcement of the remote center of motion (RCM) constraint is critical for safe and stable automatic field-of-view (FoV) adjustment. Although control-based RCM strategies are widely adopted due to their flexibility and cost-effectiveness, systematic comparison of different RCM formulations and image-based visual servoing (IBVS) frameworks remains challenging due to the lack of a unified and reproducible benchmark. This paper presents an open-source simulation framework integrating three representative RCM modeling approaches and six IBVS-based control architectures within a unified velocity-level formulation, enabling controlled and consistent evaluation. Through structured case studies, the framework reveals key structural sensitivities arising from modeling and controller interactions, including the impact of tangent-plane definition, constraint dimensionality, open- versus closed-loop enforcement, and robustness near kinematic singularities. All resources are released and demostrations are provided in the supplementary video, providing a reproducible foundation for RCM-constrained visual servoing research.
Jing Zhang, Mengtang Li