CheXthought: A global multimodal dataset of clinical chain-of-thought reasoning and visual attention for chest X-ray interpretation
Authors: Sonali Sharma, Jin Long, George Shih, Sarah Eid, Christian Bluethgen, Francine L. Jacobson, Emily B. Tsai, Global Radiology Consortium, +2 more
Organizations: Center for Artificial Intelligence in Medicine and Imaging, Stanford University, Stanford, CA, USA · Department of Radiology, Stanford University, Stanford, CA, USA · Department of Pediatrics, Stanford University School of Medicine, Stanford, California, USA · Department of Radiology, Weill Cornell Medicine, New York, NY, USA · Department of Radiology, Brigham and Women’s Hospital, Boston, MA, USA · *Global Radiology Consortium · University of California, Berkeley, CA, USA · University of California, San Francisco, CA, USA · Department of Biomedical Data Science, Stanford University, Palo Alto, CA, USA
Abstract
Chest X-ray interpretation is one of the most frequently performed diagnostic tasks in medicine and a primary target for AI development, yet current vision-language models are primarily trained on datasets of paired images and reports, not the cognitive processes and visual attention that underlie clinical reasoning. Here, we present CheXthought, a global, multimodal resource containing 103,592 chain-of-thought reasoning traces and 6,609,082 synchronized visual attention annotations across 50,312 multi-read chest X-rays from 501 radiologists in 71 countries. Our analysis reveals clinical reasoning patterns in how experts deploy distinct visual search strategies, integrate clinical context, and communicate uncertainty. We demonstrate the clinical utility of CheXthought across four dimensions. First, CheXthought reasoning significantly outperforms state-of-the-art vision-language model chain-of-thought in factual accuracy and spatial grounding. Second, visual attention data used as an inference-time hint recovers missed findings and significantly reduces hallucinations. Third, vision-language models trained on CheXthought data achieve significantly stronger pathology classification, visual faithfulness, temporal reasoning and uncertainty communication. Fourth, leveraging CheXthought's multi-reader annotations, we predict both human-human and human-AI disagreement directly from an image, enabling transparent communication of case difficulty, uncertainty and model reliability. These findings establish CheXthought as a resource for advancing multimodal clinical reasoning and the development of more transparent, interpretable vision-language models.
Large Vision Language Models (LVLMs) show promise in medical applications, but their inability to faithfully ground responses in visual evidence raises serious concerns about clinical trustworthiness. While visual attribution methods are widely used to explain LVLM predictions, whether these explanations actually reflect the visual evidence underlying the model's decision is largely unverified, since ground-truth annotations for internal model reasoning are typically unavailable. We address this question for chest X-ray (CXR) reasoning by developing a causal evaluation framework that retains only CXR-VQA samples for which the expert-annotated region is verified, via counterfactual editing, to be causally responsible for the model's prediction. Using this framework across 11 attribution methods, six open-source LVLMs, and two output modes (direct answer and step-by-step reasoning), we find that existing attribution methods often fail to identify the evidence used by LVLMs. To address this failure, we propose MedFocus, a concept-based attribution method that localizes clinically meaningful anatomical regions via unbalanced optimal transport and measures their causal effect on model outputs through targeted interventions. MedFocus produces spatial, concept-level, and token-level attributions and substantially outperforms prior methods, taking a step toward more trustworthy attribution for medical LVLMs. Our data and code are available at https://github.com/gzxiong/medfocus/.
The evaluation of vision-language models (VLMs) for chest X-ray (CXR) analysis has largely been limited to disease-presence classification without visual grounding. Such evaluations fail to verify the expert-level lesion perception necessary to ensure the clinical reliability of VLMs. To address these limitations, we introduce CheXpercept, a sequential, multi-level perception benchmark that mirrors a radiologist's cognitive workflow across coarse-level detection, fine-level contour evaluation and revision, and semantic-level attribute extraction. To ensure high clinical fidelity at scale, we construct the dataset using a semi-automated generation pipeline paired with a review by six medical experts. CheXpercept contains 10,400 QA items derived from 2,100 CXRs, covering seven clinically critical pulmonary and cardiac lesions. To demonstrate the current landscape of VLM perception, we benchmark 14 general and medical VLMs on CheXpercept. The models achieve adequate performance only at the coarse level, with accuracy degrading precipitously on deeper visual tasks. Notably, medical VLMs show almost no perceptual advantage over their general-domain counterparts, highlighting a systemic flaw in current domain adaptation. The code and dataset will be publicly available.
Chest radiograph interpretation requires temporal reasoning over prior and current studies, yet most vision-language models are trained on static image-report pairs and lack explicit supervision for modeling longitudinal change. We introduce CheXTemporal, a dataset for temporally grounded reasoning in chest radiography consisting of paired prior-current chest X-rays (CXR) with finding-level temporal and spatial annotations. The dataset includes a five-class progression taxonomy (new, worse, stable, improved, resolved), localized spatial supervision of pathology, explicit spatial-temporal alignment across paired studies, and multi-source coverage for cross-domain evaluation. We additionally construct a 280K-pair silver dataset with automatically derived temporal and anatomical supervision for large-scale evaluation under weaker supervision. Using these resources, we evaluate multiple state-of-the-art vision-language CXR models on grounding and progression-classification tasks in a zero-shot setting. Across both gold and silver evaluations, current models exhibit consistent limitations in spatial grounding, fine-grained temporal reasoning, and robustness under distribution shift. In particular, models perform substantially better on salient progression categories such as worse than on temporally subtle states such as stable and resolved, suggesting limited modeling of longitudinal disease evolution in chest radiography.