cs.CVMay 4, 2026

Augmented Equivariant Mesh Networks for Anatomical Segmentation

Authors: Daniel Saragih

Abstract

Anatomical mesh segmentation requires models that operate directly on irregular surface geometry while remaining robust to arbitrary patient pose and mesh resolution variation. Existing task-specific mesh and point-cloud methods are not equivariant, and can degrade sharply under test-time perturbation, for example dropping by 25-26 IoU points on intraoral scan segmentation at 4040^\circ tilt. We present EAMS, an Equivariant Anatomical Mesh Segmentor built on Equivariant Mesh Neural Networks (EMNN), and evaluate it across four clinically distinct tasks spanning edge-, vertex-, and face-level supervision. We combine intrinsic mesh descriptors with anatomy-aware priors, including PCA-derived frames for dental arches and liver surfaces, and augment message passing to provide lightweight global context. Across intracranial aneurysm and intraoral segmentation, EAMS variants are competitive with specialized baselines on unperturbed inputs while remaining stable under geometric perturbations, and on liver surfaces they expose a favorable trade-off between canonical-pose accuracy and rotation robustness. These results show that a lightweight (<2<2M parameters) equivariant framework can deliver robust anatomical mesh segmentation across diverse supervision types without task-specific architectures.

Explore similar work

Jul 5, 2026cs.CV

HeartVolMesh: Cardiac Volumetric Mesh Reconstruction via Covariance-Guided Graph Deformation

Accurate patient-specific tetrahedral cardiac meshes are essential for in-silico trials, yet common segmentation-then-modelling pipelines can blur thin-wall anatomy and offer limited cross-case correspondence. We propose HeartVolMesh, which lifts each template vertex to an anisotropic Gaussian kernel and uses a 3D CNN-GNN to predict per-vertex displacements and Cholesky-parameterized covariances from volumetric images. Training is guided by a covariance-aware negative log-likelihood loss with lightweight mesh regularization. For volumetric meshing, we warp a fixed tetrahedral template to the reconstructed surface via staged alignment, non-rigid registration, and deformation propagation, preserving connectivity and correspondence by construction, with resolution controlled by template density. Experiments show consistent gains over deformation-based baselines in surface mesh accuracy and volumetric mesh fidelity.
Fengming Lin, Arezoo Zakeri, Haoran Dou +4
Jun 29, 2026cs.CV

From Raw Segmentations to Simulation-Ready Cardiac Meshes: An Automated Framework for Anatomical Reconstruction and Virtual Cohort Generation

Computational models of the human heart are widely used to study electromechanical and fluid-dynamical cardiac function and to support applications such as in silico clinical trials. However, most studies remain limited to single or patient-specific anatomies, restricting the inclusion of population-level variability required for uncertainty quantification. A key challenge is translating medical-image segmentations, which may contain artifacts, mesh defects or disjoint domains, into topologically coherent geometries suitable for multiphysics simulations. In this work, we present a semi-automatic pipeline that converts CT-based segmentations into simulation-ready cardiac meshes within a few minutes while preserving anatomical and topological consistency. Building on modern deep learning segmentation methods, the framework incorporates a template-based registration stage to regularize artifacts and enforce mesh-quality constraints. A Chamfer-distance morphing strategy deforms a high-quality template toward each segmented heart, matching individual chambers while preserving topology. The resulting meshes are watertight, isotopological, and endowed with consistent point-to-point correspondence. The pipeline is validated on 58 healthy cardiac CT scans, including all cardiac chambers and proximal vessel segments. The resulting meshes can be represented in a unified shape space, enabling the construction of a statistical shape model of the heart and major vessels. Principal Component Analysis shows that a low-dimensional latent space efficiently captures population variability, while Gaussian Mixture Modeling enables synthetic anatomy generation. Overall, the proposed framework (released open-source) provides a pathway from raw segmentations to simulation-ready cardiac geometries, enabling anatomically consistent virtual cohorts for large-scale in silico studies.
Francesco Fabbri, Martino Andrea Scarpolini, Paolo Ciancarella +4
Jun 13, 2026cs.CV

MNet++: Extended 2D/3D Networks for Anisotropic Medical Image Segmentation

This work demonstrates a full reproduction and extension of MNet, a hybrid 2D/3D convolutional network designed for anisotropic medical image segmentation. The original architecture was re-implemented within the nnU-Net framework to verify its reported performance and robustness to variable voxel spacing, known as anisotropy. Experiments were conducted on PROMISE prostate MRI and a controlled subset of LiTS liver CT under matched preprocessing and compute constraints. The reproduced MNet achieved a Dice similarity coefficient (DSC) of 89.0 +/- 0.9% on PROMISE, within 0.8% of the published result, and 94.3 +/- 1.9% / 54.6 +/- 3.1% for liver and tumor segmentation on LiTS, respectively. Two lightweight extensions were further introduced: (1) a learned Fusion Gating mechanism enabling adaptive 2D-3D feature blending, and (2) a VMamba state-space module for efficient long-range depth modelling. The Spatial Gating variant improved DSC by +0.8% with less than 3% inference overhead, while VMamba improved performance consistency, reducing PROMISE Dice variation to +/- 0.7% and achieving the strongest LiTS liver performance at 95.8% Dice. Both extensions preserved MNet robustness to anisotropy, with delta Dice = 1.5% across 1-4 mm voxel spacing. Overall, the study confirms MNet reproducibility and demonstrates that adaptive fusion and state-space modelling have the potential to further strengthen segmentation reliability under anisotropic conditions. However, further tests are required to provide definitive conclusions.
Kirsten Odendaal, Rade Bajic