cs.CVMay 15, 2026

End-to-end plaque counting and virus titration from laboratory plate images with deep learning

Authors: Eugenia MorisAlicia CostábileSebastián ReyIrene FerreiroJoaquín HurtadoLizandra Lissette LucianoMatías VillagránAisha Espino Vázquez+6 more

Abstract

Plaque assays remain the gold standard readout of virus infectivity; however, plaque counting from plate images is labor-intensive and prone to inter-operator variability. We present an end-to-end, computer-aided workflow for cytopathic effect-based virus titration directly from laboratory plaque assay images. The proposed approach combines two models derived from the Segment Anything Model (SAM): a SAM2-based well-segmentation module that localizes assay wells across heterogeneous imaging conditions, and a SAM-based plaque-segmentation model that detects and enumerates plaques within each well. The method was evaluated on a mixed dataset comprising private plaque assay images of Mayaro virus and Coxsackievirus B3, together with public Vaccinia virus images from the VACVPlaque dataset. The pipeline outputs per-well plaque counts, automatically computes plaque-forming units per milliliter (PFU/mL), and is integrated into a web-based platform that allows users to review results and organize experiments. On held-out plates (17 from MAYV/CVB3 and 22 from VACV), the workflow generalized across two plate formats (6-well and 12-well) and showed strong agreement with manual annotations (Pearson correlation coefficients of 0.92 for MAYV/CVB3 and 0.88 for VACV). Automated plaque counts were further compared with annotations from four independent experts, demonstrating high concordance. The proposed system will be open sourced and publicly released upon acceptance of this manuscript to enable reproducible, scalable, and audit-ready plaque assay analysis while substantially reducing manual annotation effort.

Explore similar work

May 3, 2026physics.app-ph

Continuous quantification of viral plaque dynamics using ultra-large-area label-free imaging enables rapid antiviral susceptibility testing

The plaque reduction assay (PRA) remains the gold standard for antiviral susceptibility testing, evaluating drug potency by measuring reductions in plaque-forming units (PFUs). However, the traditional PRA is time-consuming, labor-intensive, prone to manual counting errors, and offers limited scalability. Moreover, its reliance on destructive fixation and chemical staining reduces the assay to a static, endpoint observation, obscuring the dynamic, time-resolved kinetics of dose-dependent viral inhibition. Here, we introduce a label-free, time-resolved PRA platform that transforms the conventional assay into a continuous, high-dimensional measurement of viral infection dynamics. Our system integrates a compact lens-free imaging setup with a custom-designed ultra-large-area (100 cm^2) thin-film transistor (TFT) image sensor and deep learning-based algorithms to autonomously quantify PFU dynamics within an incubator. Validated using herpes simplex virus type-1 (HSV-1) treated with acyclovir, the platform matched chemically-stained ground truth measurements with zero false positives while accelerating readout by ~26 hours. Crucially, our system revealed that increasing drug concentrations induce temporally distinct delays and suppress new PFU formation, enabling conclusive drug efficacy evaluations within ~60 hours post-infection. This scalable, label-free framework redefines antiviral susceptibility testing as a rapid, time-resolved and information-rich measurement framework, providing a generalizable platform for virology research, high-throughput drug screening, and clinical diagnostics.
Merve Eryilmaz, Yuzhu Li, Xiao Wang +8
Jun 15, 2026cs.CV

Vision-Language Models as Zero-Annotation Oracles in Histopathology

Foreground segmentation is the critical first step of every computational pathology pipeline, yet existing methods rely on hand-tuned heuristics or supervised models that overfit to narrow stain and scanner distributions, failing silently on specialised stains such as Jones silver or Elastica van Gieson. We propose a coarse-to-fine approach that recasts foreground segmentation as a visual perception task and leverages general-purpose vision-language models (VLMs) as zero-annotation oracles. Our key insight is that tissue-versus-background discrimination is a natural-image recognition problem, not a histopathological one, so VLMs trained on internet-scale corpora generalise where domain-specific models cannot. We introduce Leica-75, a benchmark of 75 renal transplant whole-slide images spanning three stain families. On Leica-75, our method achieves the highest segmentation quality on out-of-distribution stains (Dice 0.858 +/- 0.027 on Jones, 0.853 +/- 0.041 on EVG) with 7x lower cross-stain variance than the best supervised baseline, while remaining competitive on in-distribution H&E. Few-shot prompting with automatically curated exemplars (Auto-context) rescues hard cases on Stress-32 (n=32), a curated stress-test subset (Dice 0.470 to 0.819 for the 2B model). VLM-based annotation review matches human expert consensus (kappa=0.989 for blur detection; mean precision/recall grading accuracy 0.708 vs. human 0.646 for segmentation mask review). The resulting pseudo-labels are used to distil lightweight student models that are as performant as the teacher model while running for a fraction of the cost. Our framework provides a principled, scalable solution to a persistent infrastructure bottleneck in digital pathology.
Vishal Jain, Giorgio Buzzanca, Sarah Cechnicka +6
May 21, 2026cs.CV

Detection of Virus and Small Cell Patches in Foci Images Using Switchable Convolution and Feature Pyramid Networks

Accurate detection and counting of virus patches in focus-forming unit (FFU) images, also known as foci images, are important for quantifying viral infection and analyzing cellular structures. This task is challenging because biomedical targets often vary substantially in size, density, contrast, and shape. In this paper, we propose an enhanced YOLOv2-based detector that integrates a Feature Pyramid Network (FPN) to improve multi-scale feature representation. We also incorporate a switchable atrous convolution mechanism to adapt the receptive field for fine-grained targets in dense microscopy images. The proposed method is evaluated on biomedical foci image datasets for virus patch and small cell patch detection. For small cell patch detection, the model achieves a mean average precision (mAP) of 40.5% at a 25% Intersection over Union (IoU) threshold. For FFU virus patch detection, the model achieves an mAP of 68%. These results indicate that combining FPN-based feature fusion with switchable convolution improves the suitability of YOLOv2 for specialized biomedical object detection tasks
Amrita Singh, Snehasis Mukherjee