Cardiac motion over a cardiac cycle is crucial for quantifying regional function and is strongly affected by cardiovascular diseases. Since temporally dense mesh sequences are difficult to obtain in practice, we focus on leveraging the more accessible end-diastolic frame to infer a full-cycle sequence. Due to strong regional and disease-specific differences, traditional methods often oversmooth the data by relying on generative models that are optimized for global patterns. To address this problem, we propose Region-Aware and Phenotype-Adaptive Bi-Ventricular Cardiac Motion Synthesis (RePCM) for single frame Bi-ventricular mesh motion completion. In Stage I, a reconstruction network learns vertex wise motion descriptors and clustering yields a data driven functional partition, providing an explicit motion derived region structure. In Stage II, a Region-Specific Injection Module enforces masked, synchronized region exchange within a conditional VAE, preserving localized specific dynamics and restricting cross-region mixing. A Phenotype-Adaptive Mixture-of-Experts prior conditioned on ED shape uses anatomy-guided cues to model latent motion trends and capture inter-disease variability. Experiments on three datasets covering different cardiovascular diseases show consistent gains in geometric and functional metrics and improved preservation of region specific dynamics.
Accurate cardiac anatomy modeling requires the model to be able to handle intricate interrelations among structures. In this paper, we propose VecHeart, a unified framework for holistic reconstruction and generation of four-chamber cardiac structures. To overcome the limitations of current feed-forward implicit methods, specifically their restriction to single-object modeling and their neglect of inter-part correlations, we introduce Hybrid Part Transformer, which leverages part-specific learnable queries and interleaved attention to capture complex inter-chamber dependencies. Furthermore, we propose Anatomical Completion Masking and Modality Alignment strategies, enabling the model to infer complete four-chamber structures from partial, sparse, or noisy observations, even when certain anatomical parts are entirely missing. VecHeart also seamlessly extends to 3D+t dynamic mesh sequence generation, demonstrating exceptional versatility. Experiments show that our method achieves state-of-the-art performance, maintaining high-fidelity reconstruction across diverse challenging scenarios. Code is available at https://github.com/Scalsol/VecHeart.
Accurate 3D+t whole-heart mesh reconstruction from cine MRI is a clinically crucial yet technically challenging task. The difficulty of this task arises from two coupled factors: inherently sparse sampling of 3D cardiac anatomy by 2D image slices and the tight coupling between cardiac shape and motion. Current cardiac image-to-mesh approaches typically reconstruct only a subset of cardiac chambers or a single phase of the cardiac cycle. In this work, we propose CineMesh4D, a novel end-to-end 4D (3D+t) pipeline that directly reconstructs patient-specific whole-heart mesh from multi-view 2D cine MRI via cross-domain mapping. Specifically, we introduce a differentiable rendering loss that enables supervision of 3D+t whole-heart mesh from multi-view sparse contours of cine MRI. Furthermore, we develop a dual-context temporal block that fuses global and local cardiac temporal information to capture high-dimensional sequential patterns. In quantitative and qualitative evaluations, CineMesh4D outperforms existing approaches in terms of reconstruction quality and motion consistency, providing a practical pathway for personalized real-time cardiac assessment. The code will be publicly released once the manuscript is accepted.
Accurate 4D whole-heart mesh reconstruction from sparse cine MRI is critical for creating cardiac digital twins, but remains challenging due to limited 2D slice coverage and the complex coupling between cardiac shape and motion. Existing methods often rely on intermediate contour fitting and typically reconstruct static, single-phase, or partial cardiac geometries, limiting their ability to capture full-chamber dynamics. We propose a novel end-to-end framework for reconstructing temporally resolved whole-heart meshes from multi-view 2D cine MRI sequences by learning an image-to-mesh mapping. The framework incorporates a differentiable contour renderer inspired by the Beer-Lambert attenuation principle, enabling anatomy-aware supervision of 3D+t mesh deformation through contour-based projection losses. To improve temporal consistency across the cardiac cycle, we further introduce a multi-scale temporal modeling module that integrates global cycle-level dynamics with local inter-frame coherence to generate smooth and physiologically plausible mesh trajectories. The proposed method achieved a whole-heart mean absolute error of 1.68 ± 0.31 mm and a motion jitter of 0.77 ± 0.17 mm/frame3, outperforming existing methods with lower reconstruction error and substantially improved motion smoothness. It also improved 2D contour alignment across multiple cine MRI views and supported downstream proof-of-concept electrophysiological simulation. The code will be released publicly upon acceptance of the manuscript for publication.