Geometric Workspace Analysis and Transmission-Aware Dynamics of a Serial Spherical Tool for Microsurgery

Authors: Anestis Mablekos-AlexiouLyndon da CruzChristos Bergeles

Abstract

We present a kinematic and transmission-aware design framework for a serial spherical mechanism with an additional translational degree of freedom for microsurgery. The first contribution is an analytical workspace formulation that provides geometric insight into reachable motion and enables rapid selection of rotation axis orientations without numerical optimization. The second contribution is a dynamics-informed methodology for mechanisms driven by self-locking transmissions, supporting evaluation of torque requirements for a prescribed workspace geometry. The framework is accompanied by an open-source software package for friction identification and inverse dynamics analysis. Experiments on a purpose-built robotic tool for vitreoretinal surgery validate the predictive capability of the models and demonstrate their practical utility for engineering design.

Explore similar work

Sep 8, 2026cs.RO

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device

Input devices for robotic microsurgery are frequently described as preserving the surgeon's trained technique, but the claim is rarely measured. We compared manual and teleoperated intraocular instrument motion with the trocar constraint, the instrument, the eye model and the tracking source common to both conditions, so that the control interface was the only factor varied. Prior comparisons cannot hold the instrument fixed, because a robotic instrument is not the tool used manually. Sixteen participants performed a navigation task on a commercial ophthalmic simulator by hand and through a three-degree-of-freedom input device commanding a five-joint robot. Task outcome was equal but at ceiling: every participant acquired all five targets under both interfaces with no retinal or lens injury. Execution differed on every measure. Teleoperated trials took three times as long at a quarter of the median speed, covered less than half the angular working range, and were broken into 3.5 times as many separate movements. Completion time and movement fragmentation improved substantially across four trials of practice and had not plateaued; the measures set by the configured rate ceiling and joint limit changed the least. Finger activity doubled and pinch variability tripled, so reducing instrument degrees of freedom redistributed manual effort rather than reducing it. The interface preserves the outcome and reshapes the execution.
Korab Hoxha, Mirza Imamovic, Angelo Henriques +1
Aug 4, 2026cs.RO

Forbidden Region Dynamic Active Constraints in Robot-Assisted Minimally Invasive Surgery

In robot-assisted surgery, Forbidden Region Active Constraints (FRAC) represent a control strategy that helps maintain task safety by generating anisotropic haptic guidance to surgeons. However, several challenges need to be overcome before FRAC can benefit teleoperative surgery in a clinical setting. These challenges include the ability to allow for dynamic tissue deformation, maintain energetic passivity, and speed of implementation, among others. In this study, we propose the pipeline design for an energy dissipative FRAC strategy, which accommodates the dynamic tissue deformation caused by respiratory movements, by utilizing a depth sensing camera. The proposed FRAC strategy adopts a fine mesh representation, with a total number of 122,806 polygons in the case study presented, while running at 43.48Hz. We designed in vitro trajectory tracking experiments conducted by a "virtual" surgeon to aid quantitative assessment of the method, including its effectiveness in maintaining task safety, which was confirmed by successfully maintaining a pre-defined safety distance across all trials. We also conducted comparative studies to investigate the robustness and time-efficiency of our method against other FRAC methods that rely on simple geometry AC representations. We demonstrate that our method provides a more robust and effective guidance overall, while maintaining comparable, if not lower, time costs.
Zejian Cui, Ferdinando Rodriguez y Baena
Jun 22, 2026cs.RO

A Unified Benchmark for RCM-Constrained Visual Servoing: Modeling-Controller Interaction and Robustness Analysis in Laparoscopic Robots

In robot-assisted laparoscopic minimally invasive surgery (MIS), accurate enforcement of the remote center of motion (RCM) constraint is critical for safe and stable automatic field-of-view (FoV) adjustment. Although control-based RCM strategies are widely adopted due to their flexibility and cost-effectiveness, systematic comparison of different RCM formulations and image-based visual servoing (IBVS) frameworks remains challenging due to the lack of a unified and reproducible benchmark. This paper presents an open-source simulation framework integrating three representative RCM modeling approaches and six IBVS-based control architectures within a unified velocity-level formulation, enabling controlled and consistent evaluation. Through structured case studies, the framework reveals key structural sensitivities arising from modeling and controller interactions, including the impact of tangent-plane definition, constraint dimensionality, open- versus closed-loop enforcement, and robustness near kinematic singularities. All resources are released and demostrations are provided in the supplementary video, providing a reproducible foundation for RCM-constrained visual servoing research.
Jing Zhang, Mengtang Li