Authors: Tianyu Liu, Heyu Ma, Aiduo Wang, Peiwen Li, Boyi Li, Ying Li, Dan Li, Chengcheng Liu, +1 more
Abstract
Ultrasound computed tomography (UCT) via full waveform inversion (FWI) enables high-resolution quantitative imaging for tissue characterization and disease diagnosis. However, UCT suffers from large computational burden and severe convergence issues due to highly nonlinear optimization. Deep learning can accelerate UCT reconstruction, but supervised training requires large-scale labeled datasets difficult to obtain in vivo. To address these limitations, we propose SDA-UCT, a two-stage self-supervised domain-adaptive framework for rapid and accurate UCT imaging of musculoskeletal tissues. SDA-UCT employs an attention-enhanced network (AttUCT) pre-trained on simulation datasets and transfers to in-vivo data via physics-informed self-supervised learning, effectively bridging the simulation-to-real domain gap. A Low-Rank Adaptation (LoRA) mechanism is integrated to enable efficient adaptation across diverse clinical scenarios. Results showed that AttUCT achieved high-quality SOS reconstruction for simulated human forearm with a PSNR of 29.23 dB and SSIM of 0.928, outperforming conventional FWI and existing deep learning methods. Validated on in-vivo data, SDA-UCT successfully reconstructed SOS images revealing complex anatomical structures (skin, fat, muscle, tendon, bone and bone marrow) for human forearm, in high concordance with MRI references. The LoRA mechanism adjusting only 3% of parameters achieved comparable performance to full fine-tuning. The rapid reconstruction (5 ms per frame) enables real-time 3D visualization, achieving five-orders-of-magnitude improvement over traditional FWI. This work represents the first self-supervised domain-adaptive deep learning for rapid, high-resolution in-vivo UCT imaging, showing potential for musculoskeletal disease diagnosis.
Computed tomography (CT) is indispensable for clinical diagnosis and image-guided interventions but exposes patients to ionizing radiation, motivating the development of safer imaging alternatives. Ultrasound (US) is non-ionizing and widely accessible; however, it is highly operator dependent and lacks quantitative tissue characterization, often leading to diagnostic uncertainty and unnecessary CT examinations. This work presents a 3D ultrasound-derived pseudo-CT (UD-pCT) framework that generates CT-like anatomical reference volumes inferred from US, without aiming to reproduce physically accurate Hounsfield Units. Paired 3D kidney US and CT volumes from the TRUSTED dataset are first spatially aligned using a landmark-based multimodal registration pipeline, creating high-quality paired inputs for supervised training of an adversarial framework. The proposed Bottleneck Transformer Residual U-Net3D (BT-ResUNet3D) model employs a 3D residual encoder-decoder generator augmented with a transformer bottleneck, enabling effective modeling of fine-grained local anatomical structures as well as long-range volumetric dependencies, while a 3D Conditional PatchGAN discriminator enforces local structural realism in the synthesized pseudo-CT volumes. Quantitative evaluation using PSNR and SSIM demonstrates that the proposed method outperforms established baselines in structural fidelity and perceptual image quality. The UD-pCT volumes provide real-time anatomical reference for operator guidance, potentially reducing acquisition variability and unnecessary CT use. A limitation of this study is the relatively small paired dataset, which may limit the generalizability of the proposed model.
Self-supervised pre-training paradigm has gained increasing prominence for learning transferable representations in medical imaging, yet existing methods for ultrasound (US) images operate at the image or frame level, overlooking the anatomical context for clinical-aligned representation learning. In this work, we propose an anatomy-anchored ultrasound self-supervision framework ANAUS that shifts representation learning from generic visual regions to clinically meaningful anatomical structures. Utilizing a learnable latent prompt engine alongside a one-time domain adaptation on existing public image-mask pairs, we empower the LP-SAM module to achieve annotation-free anatomy delineation at scale. Building upon this anatomical grounding, we propose a dual-policy self-supervised learning paradigm consisting of inter-view semantics-aware anatomy-separating alignment and contextual core-region prediction to enhance representation learning. Specifically, the former enforces feature invariance within identical anatomical regions while promoting discriminability across distinct structures; the latter compels the model to reconstruct corrupted regions, thereby capturing fine-grained structural details. Extensive evaluations on six public datasets demonstrate that ANAUS consistently outstrips current state-of-the-art methods while maintaining the computational efficiency essential for clinical deployment. Code is available at https://github.com/zhcz328/ANAUS.
The inherent electronic and speckle noise complicates clinical interpretation of ultrasound images. Conventional denoising methods rely on explicit noise assumptions whose validity diminishes under composite noise conditions. Learning-based methods are usually pretrained in a limited image domain using a labeled dataset, which implies inevitable domain shift in complex in vivo environments. This study proposes a Pyramid Self-Contrastive Learning (PSCL) framework for test-time ultrasound image denoising without pretraining. Given multiple noisy samples from only one-shot imaging, PSCL disentangles anatomical similarity and noise randomness into separate pyramid latent spaces. The clean image is then decoded from the anatomy space while discarding the noise space. We first apply PSCL to synthetic aperture ultrasound (SAU), where an Aperture-to-Aperture loop serves as a self-supervised proxy task to ensure denoising fidelity. Simulation experiments, including noise levels from 0 to 30 dB and inclusion geometries from simple to complex, demonstrated improvements of 69.3% in SNR and 34.4% in CNR. The in vivo results showed 84.8% SNR and 25.7% CNR gains using only two aperture data of the heart in six echocardiographic views, liver, and kidney. PSCL delivers clear images across diverse imaging targets and configurations, paving the way for more reliable anatomical visualization without domain shift and pretraining costs.