Purpose: Echo-planar imaging (EPI) in low-field (LF) and ultra-low-field MRI (ULF) suffers from severe Nyquist ghost artifacts due to odd-even k-space misalignment. This study develops a reference-free artifact correction pipeline that reduces reliance on conventional reference scans while achieving improved ghost suppression. Methods: Starting from the traditional reference-scan-based ghost artifact correction method, we first introduce a peak-alignment-based ghost artifact correction method to correct odd-even line displacement without reference data. To further reduce residual artifacts, an interpolation-and-resampling strategy is applied. The combined method was evaluated using EPI and diffusion-weighted EPI data in LF and ULF. Results: The proposed pipeline effectively mitigated Nyquist ghosts, improved structural continuity, and enhanced signal uniformity. Peak-alignment-based ghost artifact correction method alone provided comparable artifact suppression to reference-scan-based ghost artifact correction method, while interpolation and resampling further suppressed residual artifacts, enabling reliable visualization of brain structures under ULF conditions. Conclusion: A practical, reference-free correction pipeline is presented for LF and ULF EPI, combining peak-alignment-based ghost artifact correction method and interpolation-resampling to achieve efficient ghost suppression and expand the clinical applicability of low-field MRI systems, providing both theoretical guidance and practical experience for ULF EPI-based DWI imaging.
Echo Planar Imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field and distortion-free image directly from k-space data, without depending on an intermediate parallel-imaging reconstruction for the correction. The image and the B0 field are each represented as a superposition of Gaussian primitives embedded within an MRI physics forward model. The explicit, continuous parameterization captures both smooth regions and tissue boundaries and supports rotated-view EPI acquisitions without interpolation. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Rotated views distribute distortions across multiple phase-encoding orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value and high acceleration. Extensive visual comparisons further show improved detail fidelity and noise suppression.
Ultra-low-field (ULF) MRI offers portable and accessible neuroimaging but suffers from reduced signal-to-noise ratio and limited spatial resolution compared to high-field (HF) systems. Acquiring paired ULF-HF data for supervised enhancement is often difficult, particularly in resource-limited settings. We introduce ULF-Synth, a framework that combines: (i) acquisition-based synthesis of realistic ULF images from HF volumes to create large-scale paired training data, (ii) a spatial-frequency domain objective that prioritizes recovery of high-frequency anatomical detail. This formulation is architecture-agnostic, consistently improving structural similarity and perceptual fidelity across encoder-decoder, adversarial, and diffusion-based translation models. When trained exclusively on synthetic data, the resulting models generalize effectively to real 64mT ULF acquisitions, improving downstream multiclass brain segmentation and achieving higher radiologist preference and diagnostic acceptability in a blinded reader study. These findings demonstrate that synthetic paired supervision provides a practical and scalable pathway for enhancing ULF MRI without requiring real paired acquisitions. Code, Models and Dataset: https://github.com/toufiqmusah/ULF-Synth
Ultra-low-field (ULF) MRI offers portable and low-cost imaging but suffers from poor image quality. To address this, we present our submission to the 2025 ULF Enhancement Challenge (ULF-EnC), where the goal is to synthesise high-field-like MRIs from 64 mT scans. Our pipeline enhances ULF MRI through a combination of anatomical conditioning and model ensembling. We first generate tissue segmentation priors using a Swin UNETR trained solely on challenge-provided data. These priors condition two independent enhancement networks - a CycleGAN and a transformer-based residual enhancement model (T-REX) - each trained to synthesise 3 T-like MRIs. Outputs from both models are combined using a weighted average. Our approach produces enhanced MRIs that were comparable to high-field scans both quantitatively and qualitatively.