cs.CVMay 25, 2026

TriDP-PTM: a three-stage distortion-perception tradeoff guides the pre-training model for radar cardiac sensing

Authors: Jinye LiAidong MenYang LiuQingchao Chen

Organizations: National Institute of Health Data Science, Peking University, Beijing, China · Institute of Medical Technology, Peking University, Beijing, China · Beijing University of Posts and Telecommunications, Beijing, China · School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing, China · Wangxuan Institute of Computer Technology, Peking University, Beijing, China · State Key Laboratory of General Artificial Intelligence, Peking University, Beijing, China

Abstract

Cardiovascular diseases (CVDs) remain a leading cause of death globally, necessitating continuous, accurate non-invasive cardiac monitoring. While non-contact radar-based approaches show great promise, they often employ a single "distortion-driven" or "perception-driven" paradigm, frequently facing a trade-off between "low distortion but weak semantic information" and "high perceptual fidelity but poor interpretability." To address this, we propose a Three-stage Distortion-Perception Pre-Training Model (TriDP-PTM), a radar-based multi-scale fusion dual-path framework that systematically compares the "direct radar-to-task" path against an "indirect radar-to-ECG-to-task" path. By integrating an ECG generator with a feature discriminator to form a composite loss function, our approach effectively incorporates medical priors - such as ECG morphology and rhythm - into downstream tasks. Through empirical analysis, we reveal that this trade-off manifests in three distinct phases (Positive-Sum, Coopetitive, and Negative-Sum), showing optimal downstream clinical accuracy typically emerges in the coopetitive stage. Extensive experiments on a dataset involving 30 subjects across 5 physiological states reveal that the indirect path consistently outperforms the direct path in diverse tasks, achieving 0.80 mean IoU in waveform segmentation, 98.3% average classification accuracy across four tasks, and a 56% MAE reduction in blood pressure regression compared to the strongest baselines. These findings validate our framework and indicate that, within the indirect radar-to-ECG pathway, appropriately weighting distortion and perception losses to operate in the coopetitive regime is critical for achieving both clinically interpretable ECG morphology and strong downstream accuracy in non-contact cardiac monitoring.

Explore similar work

May 25, 2026cs.CV

Towards 3D heart mesh generation using contactless radar imaging and physics-informed neural network

Cardiac function evaluation necessitates continuous, non-invasive monitoring, a capability limited in MRI. Millimeter-wave (mmWave) radar and its Synthetic Aperture Radar (SAR) mode offer a privacy-preserving and portable point-of-care clinical applications. However, reconstructing high-fidelity 3D cardiac geometry from SAR remains an open challenge. Traditional radar methods generate sparse point clouds that lack continuous surface topology. Meanwhile, direct application of optical reconstruction networks performs poorly due to the severe speckle noise and ambiguous boundaries inherent in SAR images. To bridge this gap, we propose SAR2Mesh, a novel framework that reformulates the task as a coarse-to-fine mesh deformation process. By initializing with a topological template, our approach explicitly preserves anatomical connectivity through progressive mesh deformation.We introduce a geometry-aware feature projection module to extract multi-view features via 3D-to-2D sampling, and a physics-informed radar loss to enforce consistency between the predicted geometry and raw radar echoes. Furthermore, we present Cardiac Mesh-SAR, the first large-scale paired SAR-mesh dataset. Extensive experiments demonstrate that SAR2Mesh significantly outperforms existing image-based baselines, achieving accurate and physically consistent cardiac reconstructions.
Jinye Li, Chenxi Fu, Minghang Zheng +3
Aug 13, 2026cs.LG

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Hamza Shafiq, Hung Manh Pham, Bin Zhu +3
Sep 15, 2025cs.SD

Scaling to Multimodal and Multichannel Heart Sound Classification with Synthetic and Augmented Biosignals

Cardiovascular diseases (CVDs) are the leading cause of death worldwide, accounting for approximately 17.9 million deaths each year. Early detection is critical, creating a demand for accurate and inexpensive pre-screening methods. Deep learning has recently been applied to classify abnormal heart sounds indicative of CVDs using synchronised phonocardiogram (PCG) and electrocardiogram (ECG) signals, as well as multichannel PCG (mPCG). However, state-of-the-art architectures remain underutilised due to the limited availability of synchronised and multichannel datasets. Augmented datasets and pre-trained models provide a pathway to overcome these limitations, enabling transformer-based architectures to be trained effectively. This work combines traditional signal processing with denoising diffusion models, WaveGrad and DiffWave, to create an augmented dataset to fine-tune a Wav2Vec 2.0-based classifier on multimodal and multichannel heart sound datasets. The approach achieves state-of-the-art performance. On the Computing in Cardiology (CinC) 2016 dataset of single channel PCG, accuracy, unweighted average recall (UAR), sensitivity, specificity and Matthew's correlation coefficient (MCC) reach 92.48%, 93.05%, 93.63%, 92.48%, 94.93% and 0.8283, respectively. Using the synchronised PCG and ECG signals of the training-a dataset from CinC, 93.14%, 92.21%, 94.35%, 90.10%, 95.12% and 0.8380 are achieved for accuracy, UAR, sensitivity, specificity and MCC, respectively. Using a wearable vest dataset consisting of mPCG data, the model achieves 77.13% accuracy, 74.25% UAR, 86.47% sensitivity, 62.04% specificity, and 0.5082 MCC. These results demonstrate the effectiveness of transformer-based models for CVD detection when supported by augmented datasets, highlighting their potential to advance multimodal and multichannel heart sound classification.
Milan Marocchi, Matthew Fynn, Kayapanda Mandana +1