eess.IVMay 29, 2026

Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts

Authors: Honglin XiongYuxian TangFeng LiYulin WangLei XiangDinggang ShenQian Wang

Abstract

Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability. Existing deep learning methods are typically contrast-specific and fail to generalize across diverse modalities and artifact severities. We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction. ScanCLIP, pretrained on over 30,000 MRI text-image pairs, derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features. A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction. A dual-pathway decoder reconstructs both the clean image and residual artifact map, enforcing image-space consistency. On IXI and HCP benchmarks, our method improves PSNR by 0.75 dB and SSIM by up to 0.0279 over state-of-the-art approaches, with larger gains at higher artifact severities. It further demonstrates robust zero-shot generalization on real-world clinical data acquired with unseen scanning parameters, where existing methods either fail to remove artifacts or introduce additional distortions.

Explore similar work

Aug 10, 2026cs.CV

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.
Mojtaba Safari, Shansong Wang, Zach Eidex +4
May 21, 2026cs.CV

MotionDPS: Motion-Compensated 3D Brain MRI Reconstruction

Magnetic resonance imaging (MRI) is highly susceptible to patient motion due to its relatively long acquisition times and the fact that data are acquired sequentially in k-space. Even small patient movements introduce phase inconsistencies across measurements, leading to severe artifacts such as blurring, ghosting, and geometric distortions that can compromise diagnostic quality. Retrospective motion compensation remains challenging, particularly in accelerated acquisitions, due to the ill-posed nature of the joint reconstruction and motion estimation problem. In this work, we propose a unified Bayesian framework for motion-compensated 3D MRI that jointly estimates the anatomical image, rigid-body motion parameters, and coil sensitivity maps directly from motion-corrupted k-space data. Our approach integrates pretrained 3D complex-valued score-based diffusion models as expressive anatomical image priors within a physics-based forward model. Inference is performed by alternating diffusion posterior image updates with efficient proximal optimization steps for motion and coil sensitivity estimation, enabling fully unsupervised reconstruction without the need for paired motion-free training data. Experiments on simulated and real-motion brain MRI datasets demonstrate that the proposed method achieves improved image quality and motion robustness compared to state-of-the-art classical and learning-based motion correction techniques, particularly in the presence of severe motion and high acceleration.
Antonio Ortiz-Gonzalez, Erich Kobler, Lukas Schletter +1
Apr 16, 2026cs.CV

Attention-Gated Convolutional Networks for Scanner-Agnostic Quality Assessment

Motion artifacts present a significant challenge in structural MRI (sMRI), often compromising clinical diagnostics and large-scale automated analysis. While manual quality control (QC) remains the gold standard, it is increasingly unscalable for massive longitudinal studies. To address this, we propose a hybrid CNN-Attention framework designed for robust, site-invariant MRI quality assessment. Our architecture integrates a hierarchical 2D CNN encoder for local spatial feature extraction with a multi-head cross-attention mechanism to model global dependencies. This synergy enables the model to prioritize motion relevant artifact signatures, such as ringing and blurring, while dynamically filtering out site-specific intensity variations and background noise. The framework was trained end-to-end on the MR-ART dataset using a balanced cohort of 200 subjects. Performance was evaluated across two tiers: Seen Site Evaluation on a held-out MR-ART partition and Unseen Site Evaluation using 200 subjects from 17 heterogeneous sites in the ABIDE archive. On seen sites, the model achieved a scan-level accuracy of 0.9920 and an F1-score of 0.9919. Crucially, it maintained strong generalization across unseen ABIDE sites (Acc = 0.755) without any retraining or fine-tuning, demonstrating high resilience to domain shift. These results indicate that attention-based feature re-weighting successfully captures universal artifact descriptors, bridging the performance gap between diverse imaging environments and scanner manufacturers.
Chinmay Bakhale, Anil Sao