cs.CVJun 3, 2026

What neurosurgeons need to see: synthetic intra-operative MRI from ultrasound for brain-shift compensation in brain tumour surgery

Authors: Santiago CepedaOlga Esteban-SinovasIgnacio ArreseRosario Sarabia

Organizations: Department of Neurosurgery, Neurovascular Unit Río Hortega University Hospital, Valladolid, Spain · Specialized Group in Biomedical Imaging and Computational Analysis (GEIBAC)2026 Instituto de Investigación Biosanitaria de Valladolid (IBioVALL), Valladolid, Spain

Abstract

Maximal safe resection is the primary objective in glioma surgery. Neuronavigation guidance is progressively degraded by brain shift after dural opening. Intraoperative MRI can compensate but needs dedicated infrastructure and is rarely available, whereas intraoperative ultrasound (ioUS) is inexpensive, repeatable, and compatible with routine workflows. Navigation systems combining ioUS with preoperative MRI usually rely on rigid registration; even deformable multimodal registration is limited by ultrasound speckle contrast, a narrow field of view, and the inability to represent structures absent from the preoperative scan, most critically the resection cavity and residual tumor. We propose an end-to-end pipeline that generates a new whole-brain MRI volume in the preoperative imaging space by merging the preoperative MRI, a synthetic MRI generated from the ioUS, and a deformable registration anchored on that synthetic image. It integrates a 2.5D residual-transformer synthesis backbone (ResViT-2.5D) and a two-stage registration coupling NiftyReg with a synthesis-anchored SynthMorph stage, operating directly on raw scanner inputs. On a post-resection ReMIND cohort, ResViT-2.5D produced synthetic images closely matching the intraoperative T2 across structural, intensity, and perceptual metrics. In 14 subjects with 215 expert landmarks, the synthesis-anchored registration reduced the mean target registration error from 6.27 to 5.86 mm, matching a strong classical NiftyReg baseline (5.85 mm) while yielding a diffeomorphic deformation field in every subject. The contribution is not a gain in registration accuracy but the integrated volume itself, which inside the ultrasound field of view it reflects the intraoperative post-resection state. This provides the surgeon with an MRI-like update of the operative field with potential for integration into surgical-navigation workflows.

Explore similar work

May 30, 2026cs.CV

A Systematic Benchmark of Intraoperative Ultrasound-to-MR Synthesis for Brain Tumour Surgery

Intraoperative ultrasound (ioUS) is a versatile, cost-effective modality in brain tumour surgery, but its interpretation is difficult: acquisition planes are non-standard, artefacts are modality-specific, and its appearance differs markedly from the preoperative MRI on which surgical-planning tools, segmentation models and the surgeon's experience rely. Synthesising MRI-like images from ioUS could let this MRI-based infrastructure be reused intraoperatively without an extra scan. Most prior work evaluates a single architecture in isolation; to our knowledge, no benchmark has spanned architectural paradigms, inference regimes and downstream-task endpoints under a common protocol. We address this gap on the public ReMIND data set (76 patients; 153 paired ioUS/T2w and 104 paired ioUS/FLAIR studies; 60/16 patient-level train/held-out split). Six generators (four GAN baselines: Pix2Pix, SwinPix2Pix, CycleGAN, CUT; the transformer-augmented ResViT; and the few-step diffusion model SynDiff) were each trained under four inference regimes (2D, 2.5D, 2D + 3D-refinement, full-3D) and two targets (T2w only; T2w + FLAIR multi-task), yielding 48 experiments. Image-fidelity metrics (SSIM, PSNR, MAE, LPIPS) were complemented by an nnU-Net v2 downstream segmentation evaluation (tumour and resection cavity) and by subgroup analyses by histological grade and reoperation. No architecture dominated every axis, and, critically, perceptual quality tracked downstream utility most closely (LPIPS, r=-0.66, p<0.001), whereas higher SSIM was associated with worse utility (r=-0.64, p<0.001); SynDiff-2.5D best preserved downstream segmentation (U_Dice=0.55). Perceptual and downstream-task metrics should therefore be reported alongside or in preference to global SSIM, and architecture choice conditioned on surgical phase, patient history and clinical objective.
Olga Esteban-Sinovas, Santiago Cepeda, Ignacio Arrese +1
Feb 9, 2026eess.IV

Data-Driven Registration and Modeling of Brain Deformation for Image-Guided Neurosurgery: A Systematic Review

Accurate compensation of brain deformation is critical for reliable image-guided neurosurgery. Surgical manipulation and tumor resection induce tissue motion, causing preoperative planning images to become misaligned with the intraoperative anatomy. In this systematic review, we examine data-driven methods developed between 2020 and 2025 for brain deformation registration and modeling, with a particular focus on learning-based approaches. A comprehensive literature search was conducted in PubMed, IEEE Xplore, Scopus, and Web of Science using predefined inclusion and exclusion criteria for computational methods addressing brain deformation in neurosurgical imaging, resulting in 46 eligible studies. We provide a unified analysis of methodological strategies, including deep learning-based image registration, direct deformation field regression, synthesis-driven multimodal alignment, resection-aware architectures for handling missing correspondences, and hybrid models integrating biomechanical priors. We also examine dataset utilization, evaluation metrics, validation protocols, and the assessment of uncertainty and generalization across studies. While learning-based methods demonstrate promising accuracy and computational efficiency, current approaches remain limited by out-of-distribution robustness, standardized benchmarking, interpretability, and readiness for clinical deployment. Our review highlights these gaps and outlines future directions toward more robust, generalizable, and clinically translatable solutions for neurosurgical guidance. By organizing recent advances and critically assessing evaluation practices, this work provides a comprehensive reference for researchers and clinicians working on data-driven registration and modeling of brain deformation.
Tiago Assis, Colin P. Galvin, Joshua P. Castillo +12
Apr 19, 2026cs.CV

Deep learning based Non-Rigid Volume-to-Surface Registration for Brain Shift compensation Using Point Cloud

Soft-tissue deformation remains a major limitation in image-guided neurosurgery, where intra-operative anatomy can deviate substantially from pre-operative imaging due to brain shift, compromising navigation accuracy and surgical safety. Existing compensation methods often rely on intra-operative MRI, CT, or ultrasound, which are disruptive and difficult to integrate repeatedly into the surgical workflow. In contrast, partial 3D cortical surfaces can be reconstructed as point clouds from stereoscopic microscopes or laser range scanners (LRS), capturing only a limited portion of the exposed cortex. This makes point cloud registration a practical alternative without interrupting surgery; however, such partial and noisy observations make deformation estimation highly challenging. In this study, we propose a deep learning-based framework for non-rigid volume-to-surface registration, enabling dense displacement field estimation from sparse intra-operative surface observations without explicit point correspondences or volumetric intra-operative imaging. The network leverages multi-scale point-based feature extraction and a hierarchical deformation decoder to capture both global and local deformations. The key contribution lies in integrating partial intra-operative surface information into the full pre-operative point cloud domain, enabling implicit correspondence learning and dense deformation recovery under limited visibility. Quantitative results demonstrate accurate recovery of fine-scale deformations, achieving an Endpoint Error (EPE) of 1.13 +/- 0.75 mm and RMSE of 1.33 +/- 0.81 mm under challenging partial-surface conditions. The proposed approach supports automatic, workflow-compatible brain-shift compensation from sparse surface observations.
Eashrat Jahan Muniya, Gernot Kronreif, Ander Biguri +2