eess.IVJun 15, 2026

Phenotyping TPF via Self-Supervised Learning: A Label-Agnostic Framework with Expert Validation

Authors: Miral ElnakibMuhammad SaadAhmad Al-Kabbany

Organizations: Faculty of Sciences Alexandria University · Multimedia Interaction and Communication Lab Wearables, Biosensing, and Biosignal Processing Research Lab Arab Academy for Science and Technology

Abstract

The full potential of artificial intelligence in tibial plateau fracture characterisation remains unrealised, constrained by a fundamental dependency on labelled datasets whose consistency cannot be guaranteed: conventional classification schemes such as Schatzker and AO/OTA suffer from inter-observer variability, causing supervised models to learn human disagreement rather than stable fracture morphology. We design, implement, and validate a label-agnostic framework that eliminates this constraint by learning fracture representations directly from imaging data without observer-assigned labels. A RadImageNet-pretrained ResNet-50 encoder is fine-tuned on 154 cleaned knee radiographs using the SimCLR contrastive objective, preceded by a data cleaning protocol and followed by UMAP dimensionality reduction and k-means clustering to discover four imaging-derived phenotypes. Phenotype validity is assessed through a blinded expert review protocol administered to two independent clinicians. The four phenotypes demonstrate robust stability (bootstrap ARI = 0.319 +/- 0.041), strong internal cohesion (silhouette = 0.511), and coherence ratings of 3-5/5 from both reviewers under blinded conditions; one phenotype was unanimously identified as exhibiting comminution -- a high-complexity feature isolated without any supervisory signal. Inter-partition comparison against Schatzker labels yields ARI = 0.013, confirming orthogonality to conventional classification boundaries. Notably, expert reviewers anchored to established classification vocabularies perceived imaging-derived groups as heterogeneous precisely where Schatzker alignment was lowest, suggesting that Schatzker-trained perception and label-agnostic embedding geometry measure orthogonal dimensions. These findings establish label-agnostic SSL phenotyping as a reproducible and clinically interpretable complement to conventional classification.

Explore similar work

Aug 7, 2026physics.med-ph

Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings

Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement. Zero echo time (ZTE) MRI visualizes cortical bone and yields FAI angles that agree with CT, but automated angle extraction remains limited. We developed and validated automated FAI angle computation from ZTE MRI and assessed agreement with expert manual measurements in a cross-sectional study (level of evidence, 3). Pelvic ZTE MRI was acquired in 73 participants (mean age 36.8 +/- 18.5 years; 51 women, 22 men), yielding 135 hips. nnU-Net was trained on 100 manually curated hips to segment the femur, pelvis, and three osseous landmarks. Custom geometric algorithms computed alpha, femoral neck-shaft, Tonnis, coronal and sagittal center-edge, and acetabular version angles from inferred segmentations. Measurements on 35 test hips were compared with the mean of two radiologists' manual measures using intraclass correlation (ICC) and Bland-Altman analysis. Dice exceeded 0.96 for bone and ranged from 0.65 to 0.83 for landmarks. Median landmark error was 0.38 mm (femoral head), 0.82 mm (lateral acetabulum), and <2.5 mm (medial acetabulum, greater trochanter). Interrater ICC was excellent for acetabular version, coronal center-edge, and Tonnis (>=0.82) but poor for alpha and femoral neck-shaft. Model versus rater-mean agreement was excellent for acetabular version, coronal center-edge, and Tonnis (0.92-0.96), good for mid-acetabular sagittal center-edge (0.74), and fair for alpha (0.45) and femoral neck-shaft (0.55). Model Bland-Altman limits of agreement were narrower than interrater limits for most angles. Fully automated morphometric assessment from ZTE MRI is feasible and performs comparably to expert readers for most coverage and version angles.
Jack Consolini, Eric A. Bogner, Meghan Sahr +3
Jun 13, 2026cs.CV

Landmark-free Assessment of Lower-limb Alignment with Implicit Neural Shape Functions from Knee Radiographs

Radiographic assessment of lower-limb alignment (LLA) is important for predicting joint health and surgical outcomes in total knee arthroplasty. Traditional measurement methods are manual and time-consuming, while recent machine learning approaches typically rely on locating a fixed set of anatomical landmarks. This dependence limits flexibility and may require re-annotation when clinical definitions change. To address this, we propose an automated workflow using Implicit Neural Shape Functions (INSF). Rather than relying on explicit landmark coordinates, we encode the anatomy into a compact latent space and regress clinical alignment measurements directly from these latent codes. This architecture allows for rapid extendability to new tasks without altering the backbone representation. We trained our method on an internal dataset of 566 knee radiographs, each annotated with the outline of the femur and tibia. We evaluated it on both an internal test dataset of 50 patients and a separate external set of 402 preoperative cases from the MRKR dataset. Manual clinical measurements are available for these data, and the MRKR measurements will be made publicly accessible. Performance was comparable to state-of-the-art landmark-based methods and manual agreement, while offering a flexible shape representation that can be extended to additional measurement tasks.
Zhisen Hu, Antti Kemppainen, David Johnson +5
May 28, 2026cs.CV

Low-Magnification SEM May Suffice: Interpretable Deep Learning for Multi-Scale Fracture-Cause Classification in Zirconia-Toughened Alumina

Reliable identification of fracture origins in alumina matrix composite hip and knee implants is critical for quality assurance and patient safety, yet current fractographic workflows are time-consuming, partly subjective, and reliant on high-magnification scanning electron microscopy (SEM). We present an interpretable vision-transformer (ViT) workflow for automated classification of fracture causes in an alumina matrix composite (BIOLOX delta, CeramTec GmbH) widely used in total joint replacements. A dataset of 8,493 SEM images (50x-10,000x) was curated from five years of in-production burst and proof tests and annotated into three defect categories defined along the manufacturing chain: green body, hard machining, and material defects. Under severe class imbalance, the fine-tuned ViT reached an accuracy of 0.907 and a macro-F1 of 0.888 in stratified five-fold cross-validation, with a two-stage perceptual-hash/SSIM leakage audit confirming negligible specimen overlap. Notably, performance at low magnification (50x) was comparable to that at high magnification (1k-10kx), indicating that macro-scale features - mirror geometry and hackle line fields - already encode sufficient diagnostic signal. Grad-CAM attributions consistently localised on canonical fractographic cues (mirrors, hackles, pores, machining marks), aligning with established fractographic criteria. Together, these results position interpretable ViTs as a complementary tool for ceramic-implant quality assurance, enabling low-magnification pre-screening and reducing reliance on time-intensive high-magnification inspection.
Julian Schmid, Pawel Astankow, Tom Vater +3